BỘ CẢNH BÁO ĐA ĐIỂM NEW-COSMOS UV-810

BỘ CẢNH BÁO ĐA ĐIỂM NEW-COSMOS UV-810

BỘ CẢNH BÁO ĐA ĐIỂM NEW-COSMOS UV-810

BỘ CẢNH BÁO ĐA ĐIỂM NEW-COSMOS UV-810

BỘ CẢNH BÁO ĐA ĐIỂM NEW-COSMOS UV-810
BỘ CẢNH BÁO ĐA ĐIỂM NEW-COSMOS UV-810

Sản Phẩm

  • BỘ CẢNH BÁO ĐA ĐIỂM NEW-COSMOS UV-810

  • Giá : Liên hệ
  • MASP : UV-810, UVB-810
  • Nhà sản xuất : NEW-COSMOS
  • Compact design Standard cases for 3/6/9/12/15 points are available Wide variety of input power sources Can be equipped with a Zener barrier Combination of the V3 series (or V/V2 series) units allows detection of and alarm for various gases Backup power supply unit is available with UVB-810.

Chi tiết Sản phẩm Chi tiết Sản phẩm

Model
UV-810
Points of Indicator
Up to 15 points

Combined Gas Detection Systems with V3 indicator unit, alarm unit, communication unit and various gas detector heads.

Specifications

Model UV-810
Points of Indicator Up to 15 point
(line up: 3/6/9/12/15 point type)
Alarm Accuracy As per gas detector:
– Combustible gas: within 25% of alarm value under an identical condition
– Toxic gas: within 30% of alarm value under an identical condition
Alarm Indication
Alarm Sound
Indicator unit
– Alarm lamp: blnks on alarm, lights up by reset, latching (or non-latching)
Alarm unit
– Trouble lamp:
red lamp lights up (1st stage, 2nd stage) when at least one indicator unit is activated
yellow lamp lights up when at least one indicator unit cause a malfunction
External Output Terminal for collective alarm
– 2nd alarm contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
– 1st alarm contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
– Buzzer contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
– Trouble contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
*Collective alarm contacts of 1st alarm and 2nd alarm can be changed to 1b contact (need to specify)
Terminal for individual alarm
– 2nd alarm contact: 1a non-voltage (STD) (250 VAC, 2A. 24 VDC, 2A load resistance)
– 1st alarm contact: 1a non-voltage (STD) (250 VAC, 2A. 24 VDC, 2A load resistance)
Analog output
– Gas concentration analog output signal: 4-20 mA, selectable from 1-5 V (need to specify)
Power Source AC specification: 100-240 VAC ±10%
DC specification: 24 VDC ±10% (need to specify)
Power Consumption AC input: 100-240 V, Pump power supply: 24 VDC
– Power consumption (VA) = (V3 x points of indicator + VAS) x 1.25 (SW power loss)
DC input (24 V ±10%), Pump power supply: 24 VDC
– Power consumption (W) = (V3 x points of indicator + VAS)
**V3 includes power consumption of gas detector
Operating Temperature/
Humidity
-10 to +40 °C (excluding rapid temperature change)
10 to 90 %RH (excluding rapid temperature change, non-condensing)

Dimensions

プリント

 DOWNLOAD: CATALOGUE UV-810

Các sản phẩm khác

MÁY ĐO KHÍ GAS RIKEN KEIKI GP-1000

Chi tiết

Máy ghi dữ liệu khí gas riken keiki GX-8000

Chi tiết

đồng hồ điện tử đo áp suất Daiichi keiki DPM series

Chi tiết

MÁY ĐO NỒNG ĐỘ ACID,BRIX CHANH DÂY, CAM ATAGO 7101

Chi tiết

MÁY ĐO NỒNG ĐỘ KHÍ OXY AN TOÀN COSMOS XO-326IIs

Chi tiết

NHIỆT KẾ ĐO NITRAT TRONG ĐẤT HORIBA B-342

Chi tiết

Yêu cầu báo giá

Fanpage