THIẾT BỊ ĐO ĐỘ DÀY VẬT LIỆU EVIDENT OLYMPUS 38DL PLUS

THIẾT BỊ ĐO ĐỘ DÀY VẬT LIỆU EVIDENT OLYMPUS 38DL PLUS

THIẾT BỊ ĐO ĐỘ DÀY VẬT LIỆU EVIDENT OLYMPUS 38DL PLUS

THIẾT BỊ ĐO ĐỘ DÀY VẬT LIỆU EVIDENT OLYMPUS 38DL PLUS

THIẾT BỊ ĐO ĐỘ DÀY VẬT LIỆU EVIDENT OLYMPUS 38DL PLUS
THIẾT BỊ ĐO ĐỘ DÀY VẬT LIỆU EVIDENT OLYMPUS 38DL PLUS

Sản Phẩm

  • THIẾT BỊ ĐO ĐỘ DÀY VẬT LIỆU EVIDENT OLYMPUS 38DL PLUS

  • Giá : Liên hệ
  • MASP : 38DL PLUS
  • Nhà sản xuất : EVIDENT OLYMPUS
  • Thickness Measurements on Plastics, Metals, Composites, Glass, Rubber, Ceramics

Chi tiết Sản phẩm Chi tiết Sản phẩm

 

 

 

 

Key Features:


■ Dual and single element transducer compatibility
■ Wide thickness range: 0.08 mm (0.003 in.) to 635 mm
(25 in.) depending on material and transducer selection
■ Corrosion thickness gaging with dual element transducers
■ THRU-COAT® and Echo-to-Echo measurements on painted
and coated surfaces
■ Internal Oxide/Scale software option
■ Standard resolution of 0.01 mm or 0.001 in. for all
transducers
■ High Resolution software option of 0.001 mm or 0.0001 in.
with single element transducers 2.25 MHz to 30 MHz
■ Multilayer software option for measurements of up to four
layers simultaneously
■ High Penetration software option for attenuating materials
such as fberglass, rubber and thick casting
■ Thickness, Velocity, and time-of-flight measurements
■ Differential mode and Reduction Rate mode
■ Time-based B-scan mode; 10,000 reviewable readings per
scan
■ Olympus High Dynamic Gain technology with digital flters
■ V-Path Builder for custom V-path compensation
■ Designed for EN15317

 

Thickness Measurements on Plastics, Metals, Composites, Glass, Rubber, Ceramics

 

 

38DL PLUS Specifcations :

 

 

Dual element transducer
measurement mode
Time interval from a precision delay after the excitation pulse to the frst echo
THRU-COAT®
measurement
Measurement of true metal and coating thicknesses with a single back-wall
echo (with D7906-SM and D7908 transducers)
Thru-Paint Echo-to-Echo Time interval between two successive back-wall echoes to eliminate paint or
coating thickness
Single element transducer
measurement modes
Mode 1: Time interval between the excitation pulse and the frst back-wall echo
Mode 2: Time interval between the delay line echo and the frst back-wall echo
(with delay or immersion transducers)
Mode 3: Time interval between successive back-wall echoes following the frst
interface echo after the excitation pulse (with delay line or immersion
transducers)
Oxide: optional
Multilayer mode: optional
Thickness range 0.080 mm to 635.00 mm (0.003 in. to 25.000 in.) depending on material,
transducer surface conditions, temperature, and selected confguration
Material velocity range 0.508 mm/μs to 13.998 mm/μs (0.020 in./μs to 0.551 in./μs)
Resolution (selectable) Low: 0.1 mm (0.01 in.)
Standard: 0.01 mm (0.001 in.)
High Resolution (optional): 0.001 mm (0.0001 in.)
Transducer frequency
range
Standard: 2.0 MHz to 30 MHz (–3 dB)
High Penetration (optional): 0.50 MHz to 30 MHz (–3 dB)
GENERAL
Operating temperature
range
–10 °C to 50 °C (14 °F to 122 °F)
Keypad Sealed, color-coded keypad with tactile and audible feedback
Case Impact-resistant and water-resistant, gasketed case with sealed connectors.
Designed for IP67.
Dimensions (W x H x D) Overall: 125 mm x 211 mm x 46 mm (4.92 in. x 8.31 in. x 1.82 in.)
Weight 0.814 kg (1.80 lb)
Power supply AC/DC adaptor, 24 V; lithium-ion battery 23.760 Wh; or 4 AA auxiliary bat
teries
Battery life, lithium-ion Operating time: minimum 12.6 h, 14 h typical, 14.7 h maximum
Fast charge: 2 h to 3 h
Standards Designed for EN15317
DISPLAY
Color transflective VGA
display
Liquid crystal display, display area 56.16 mm x 74.88 mm (2.2 in. x 2.95 in.)
Rectification Full wave, RF, half-wave positive, or half-wave negative
INPUTS/OUTPUTS
USB 1.0 client
RS-232 Yes
Memory card Maximum capacity: 2 GB External MicroSD memory card
Video output VGA output standard
INTERNAL DATA LOGGER
Data logger The 38DL PLUS identifes, stores, recalls, clears, and transmits thickness
readings, waveform images, and gage confguration information through the
standard RS-232 serial port or USB port.
Capacity 475,000 thickness measurements or 20,000 waveforms with thickness
measurements
File names, IDs, and
comments
32-character fle names and 20-character alphanumeric location codes with
four comments per location
File structures Nine standard or custom application-specifc fle structures
Reports On-gage reporting of summary with statistics, Min./Max. with locations, Min.
review, fle comparison, and alarm report

Standard Package


38DL PLUS digital ultrasonic thickness gage,
AC or battery operation, 50 Hz to 60 Hz

Kits available with standard dual element
transducers

Charger/AC adaptor (100 VAC, 115 VAC,
230 VAC)

Internal data logger
GageView interface program
Test block and couplant
USB cable
Rubber protective boot with gage stand and
neck strap

User’s manual
Measurement features: THRU-COAT®, ThruPaint Echo-to-Echo, EMAT compatibility, Min./
Max. mode, two alarm modes, differential
mode, B-scan, Application Auto-Recall, temperature compensation, Average/Min. mode

 


 

 

picture: Olympus 38DL Plus at Semiki's warehouse

 

Maintenance and calibration : 

 

 We also have calibration certificate attached ( optional )
► Please re-calibrate after use for a certain period through our purchase store. Local Vietnam : SEMIKI CORP

 

 

 

 

DISTRIBUTED BY:

 

Semiki instrumentation Co., Ltd
Email:  sales@semiki.com
Office tel: +84 28 2253 3522

 

 

~DOING OUR BEST FOR YOU~

 

 

Các sản phẩm khác

ĐẦU DÒ ĐO TỪ TÍNH KANETEC TM-901PRB, TM-901AXL

Chi tiết

thiết bị đo mô men xoắn tohnichi SF / F Beam Type

Chi tiết

MODULE ĐẦU DÒ CHO MÁY CMM RENISHAW TP200 / TB200B

Chi tiết

MẪU CĂN CHUẨN ĐỘ PHẲNG OSG

Chi tiết

máy CNC CMM MITUTOYO CRYSTA-Apex V Series

Chi tiết

Bộ thước đo tuyến tính Ono sokki linear gauge GS Series

Chi tiết

Yêu cầu báo giá

Fanpage