AIKOH digital force gage RZE-S-200 is a series of tensile and compressive force measuring devices including RZE-S display and separate 3000 series loadcell measuring 200Kgf force. Semiki distributes AIKOH in Vietnam.
High precision tensile and compression force sensor is widely used. Small output difference in tensile and compression and stable performance. Large capacity type 2 kN /200kgf. Capable of measuring force in places without power supply with 3m cable to measure complex areas. Separate structure does not restrict much to the measuring positions to choose.
MODEL-3000 Series | |
Rated capacity | 20N~20kN |
Rated output | 20N : 1mV/V±1% 50N~5kN : 2mV/V±1% 10kN~20kN : 1.8mV/V±1% |
Nonlinearity | 0.1%RO |
Hysteresis | 0.1%RO |
Repeatability | 0.1%RO |
Recommended applied voltage | 20N : 6V 50N~20kN : 10V |
Allowable applied voltage | 20N : 6V 50N~20kN : 15V |
Input/output resistance | 350Ω±2% |
Insulation resistance | 2000 MΩ or over |
Temperature compensation range | -10~+70℃ |
Allowable temperature range | -20~+80℃ |
Zero point influence by temperature | ±0.1%/10℃ |
Output influenced by temperature | ±0.1%RO/10℃ |
Allowable overloading | 150% RC |
Cable length | 2m (optional) |
Tip shape | 7P-7P connector or 7P-Y terminal |
Standard accessories: Display: RZE-S, Loadcell: MODEL-3200, Cell cable (1.5m), AC adapter MODEL-780 (USB cable: includes MODEL-RZ-USB)
Caution:
• This product is designed for force measurement only. Do not use it for other purposes.
• Please pay close attention to install this products.
• Never apply strong force or impact especially on the sensing direction.
• Do not apply bending or torsion stress when setting up the sensing shaft to a measuring object.
• Do not use in the conditions of rapid temperature changes, high temperature, high humidity, near water and dusty place.
• The contents may be changed without notice in advance.
• Please note the allowable values are a little different by the selecting unit of the amplifier.
Please contact SEMIKI if you need the details
Maintenance and calibration :
► We also have calibration certificate attached ( optional )
► Please re-calibrate after use for a certain period through our purchase store.