Semiki logo
HOTLINE: +84 979761016
0

Cart

No products in the cart.

Continue shopping
Home / Shop / Swimming Pool (pH, ORP) Controller with Integrated Dosing Pump BL120
Product portfolio

Swimming Pool (pH, ORP) Controller with Integrated Dosing Pump BL120

Producer:
SKU: HANNA-BL120 Category:

– Designed to maintain pH and sanitizer in swimming pools, hot tubs and spas.

– Integrated dosing pump.

– High and low alarm

– Record data every 10 seconds.

– Password protection.

– Transfer data to computer via USB port

– Display comes with pH/ORP/temperature electrode with matching pin

– There are 2 optional configurations:

+ BL120-10: in-line

+ BL120-20: in flow (flow-cell)

Multiple configurations

The controller can be configured in one of two ways: either in-line allowing the probe and chemical injector to be installed directly into existing piping (BL120-10) or panel mounted with a bypass flow cell (BL120-20). The bypass flow cell allows calibration and maintenance of the probe without stopping the circulation pump.

Digital combination probe

The HI1036-1802 is a digital probe that measures pH, ORP, and temperature. This probe also incorporates a matching pin. The pin is considered the ground wire and is used to prevent ground loop effects from causing erroneous readings and damage to the system.

QUANTIFICATION AND CONTROL

 

PERISTILIAL DOSING PUMP SYSTEM

The BL120 is equipped with two peristaltic metering pumps with replaceable chemical resistant tubing. When using a diaphragm pump, chlorine gas formed from outgassing can collect at the pump head resulting in initial loss; with a peristaltic pump the accumulation of chlorine gas is no longer a problem when using rollers and tubing.

PROPORTIONAL PUMP CONTROL

The BL120 features proportional dosing pump control. Based on the sensitivity of the chemical processes, the controllers allow the user to adjust a proportional band. This setting determines the dosing pump time as a percentage of deviation from set points allowing for very fine control in maintaining the desired set points.

 

 

 

 

Custom flow rate

The flow rate from the metering pump is adjustable from 0.5 to 3.5L/h. Larger water lines can pump more chemicals than smaller water lines because they can take more chemicals to make the change in value. Adjustable flow rates, such as proportional ribbons, allow for better control of the desired set point.

ORP metering pump confirmation

With chlorine disinfection there is an inverse relationship between pH and ORP. If the pH increases then the ORP will decrease. The BL120 provides a pump confirmation feature that will not pump chlorine until the pH value is first adjusted if the ORP value is low even though there is sufficient chlorine present. This feature avoids wasting chemicals and avoiding higher than necessary chlorine concentrations.

 

 

 

CONNECT & DISPLAY

 

 

screen-bl121

 

Multi-function display

The BL120's multi-function display allows for three display modes. The LCD can display all three parameters at once, a 3-second cycle of a single parameter, or a real-time display with options for parameter selection, zooming, and reviewing recorded data.

 

 

Circulation pump

An internal flow switch or a mechanical relay attached to the circulation pump power supply can be connected to the BL120 inlet. When there is no flow or no power to the circulation pump, the circuit will disable the metering pumps. This will avoid pumping chemicals when there is no water in the system.

Programmable alarm system

The Hanna controller allows the user to enable or disable low and high alarms for all parameters. When enabled, all pumps will stop. The alarm system also provides pump over-dose protection if the value is not adjusted within a specified time period, the machine will alarm.

Multi-color LED indicator

The BL120 provides multiple LEDs that indicate status, maintenance, and pump operation. The STATUS LED changes color based on operational status; green is in range, yellow when user intervention is required, and red for problems. The SERVICE LEDs indicate any alarms and process errors experienced by the controller.

 

CONNECTIVITY & SECURITY

 

Record data automatically

Values for each parameter are automatically logged every 10 seconds. A new log is started each time the meter is calibrated or at the start of a new day. The logged data includes pH, ORP, and temperature values, the latest calibration data, setup configuration, and any event data. Each log is saved as a .csv file for easy transfer.

USB connection

To view and save data, users can easily transfer data to a computer using a flash drive and USB port.

Password protected

Helps restrict access to calibration, setup and review of recorded data. Password can be set and enabled/disabled in the general settings of the machine.

 

 

 

YouTube video

 

 

 

SPECIFICATIONS

pH

pH scale

0.00 to 14.00 pH

pH resolution

0.01 pH

pH accuracy

±0.05 pH

pH calibration

pH buffer: automatic, 2 points (4.01, 7.01, 10.01 pH)
pH process: 1 point, manual input

Heat compensation

automatic, -5.0 to 105.0ºC (23.0 to 221.0ºF) 

ORP

ORP scale

±2000 mV

Resolution 

1 mV

Accuracy 

±5 mV

ORP calibration

1 point, manual input

Temperature

The scale

-5.0 to 105.0ºC (23.0 to 221.0°F)

Resolution

0.1°C (0.1ºF)

Calibration

±1ºC (±1.8ºF)

General specifications

pH pump

Compatible with custom setpoints and delay bands for machine start-up and pump over-dose protection

ORP pump

Compatible with custom setpoints and delay bands for machine start-up and pump over-dose protection
Locking pH pump

Alarm

high and low with enable/disable options for all parameters
Alarm is triggered when 5 consecutive values are above/below the threshold

System alarm

Visual warning system based on LEDs
Alarm filtering options
Alarm relay control based on user settings

Alarm Relay Output (1)

SPDT 5A/230 VAC
Triggered by pH/ORP/temperature selectable alarm condition

Supported inputs (3)

low level in acid/base tank (contact open)
low level in chlorine tank (contact open)
hold input (contact open)

Pump control

Automatic and manual
Flow rate adjustable from 0.5 to 3.5 L/h

Record data

Automatically logs pH, ORP and temperature measurements, GLP and events including alarms, errors and power failures

about 60 days for 10 second sampling time
All .csv file data is transferred by USB flash drive

Password protected

Setup, calibration and review of password protected logs

Connect

USB

GLP

Calibration information including date and time for pH and ORP sensors

Digital probe input (1)

HI1036-1802 pH/ORP/temperature/matching pin digital galvanic probe with waterproof DIN connector

Electricity supply

100 – 240 VAC

Power consumption

10 VA

Environment

0 to 50 ºC (32-122 ºF); max 95% RH non-condensing

Size

245 x 188 x 55 mm (73 mm with pump);
9.6 x 7.4 x 2.2” (2.9” with pump)

Mass

1700 g

Guarantee

12 months for the machine and 06 months for the included electrodes

Supply includes

BL120-10: Pool & spa controller with pH/ORP/temperature probe HI1036-1802, with probe accessories and chemical injector
BL120-20: Pool & spa controller with flow mounted control panel, pH/ORP/temperature probe HI1036-1802, with probe accessories and chemical injector

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.