Force and mechanical measuring equipment
The HI8711 is a wall-mounted pH controller ideal for monitoring pH control processes in a variety of industrial applications. Designed for quick and easy installation, the HI8711 is equipped with a large, front-panel membrane keypad and self-diagnostics. Additionally, output configurations can be selected for connection to a recorder or PLC, between 0-20 or 4-20 mA.
The HI 8711 allows for two setpoint selection with two independent outputs for acid and alkali dosing.
The meter provides a direct input to a pH or ORP electrode or from a transmitter via a 4-20 mA input. It also provides a ±5V power input and input terminals for amplified electrodes. Additionally, the output configuration can be selected to connect a recorder or a PLC, between 0-20 or 4-20 mA.
The HI 8711 incorporates an adjustable pump overtime protection mode from 5 to 60 minutes. If the pump exceeds the selected time, an alarm will be triggered and the dosing contact will be turned off. This feature can be enabled or disabled.
FEATURES
– Inputs: BNC connection, direct wire connection to amplified probe (HI1006 supports electrode current) and 4-20 mA from a transmitter
– Automatic diagnostics to confirm offset and slope calibration and contaminated/damaged electrodes
– Automatic or manual dosing ON, OFF for alkali, acid and REDOX display dosing can be selected
– Dual setpoints with two independent dosing outputs
– Wide temperature compensation range: from -20 to 100°C
– Support matching pin connection
– There are two outputs 4-20 and 0-20 mA
– ±5V output for amplifier electrode
– Safety function – alarm relay is activated when power is suddenly cut off
– Led light
– LCD display with backlight
– Shockproof case
SPECIFICATIONS
The scale |
0.00 to 14.00 pH |
Resolution |
0.01 pH |
Accuracy @20 °C |
±0.02 pH (0 to 100 °C) ±0.05 pH (-20 to 0 °C) ±0.5% (input from transmitter) |
Input |
high impedance 1012 Ohm; reference input and matching pin available; 4-20 mA |
Output source |
±5 Vcc; max load 150 mA for amplifier electrode |
Calibration |
offset: ±2 pH with OFFSET button ; slope: 80 to 110% with SLOPE button |
Heat compensation |
fixed or automatic with Pt100, -20 to 100°C (-4 to 212°F) |
Exit |
0-20 mA or 4-20 mA (isolated) |
Setpoint relay |
2, isolated, 2 A, max 240 V, resistive load, 1000000 steps (no fuse protection) |
Setpoint scale |
Alkaline: from 0.00 to 14.00 pH; acid: from 0.00 to 14.00 pH |
Alarm relay |
1, isolated, 2 A, max 240 V, resistive load, 1000000 steps (no fuse protection) |
Alarm ladder |
0.2 to 3.00 pH |
Pump mode |
OFF/AUTO/ON with selector switch |
Overtime pumping |
Adjustable, from 5 minutes to 60 minutes with knob or not activated by belt – on rear panel |
Backlight |
Open continuously |
Electricity supply |
115 VAC ±10% or 230 VAC ±10%; 50/60 Hz |
Machine case |
ABS fireproof housing and front panel; shockproof housing |
Environment |
-10 to 50°C (14 to 122°F); RH max 95% non-condensing |
Panel size |
141 x 69 mm |
Mass |
1 kg |
Guarantee |
12 months |
Supply includes |
HI 8711 is supplied with mounting bracket and instructions. |