HI9810312 is a professional wireless pH meter, part of the HALO2 series from Hanna Instruments. 

– Compact, pocket-sized measuring pen design

– Direct pH measurement of mash, wort and beer samples.

– Accuracy ±0.05 pH

– The meter comes complete with probes, standard solutions, and batteries.

– Very popular and popular in the beer brewing industry.

 

Download for FREE to experience here!!!!

Download Hanna Lab app Download Hanna Lab app

 

 

ehanna-labHANNA LAB APP iOS & Android 

 

– HALO2 can be used as a normal pH meter

– When connecting to the application Hanna Lab equal  will turn into a pH meter with full features including: Monitoring electrode status - NCalibration reminder – Direct reading of measured values – Temperature compensation – Stability criteria – pH (mV) and temperature alarms – GLP – User ID – Data logging and export

 

 

WHY IS IT NEEDED TO MEASURE pH IN BEER PRODUCTION?

Measuring pH during beer production is important due to its influence on enzyme activity during mashing, yeast activity during fermentation, and the incorporation of flavoring ingredients. Monitoring and controlling pH allows for a consistent flavor profile and ensures a stable product. Brewers face a number of challenges when measuring pH. The mash has a high content of semi-solids and sugars formed from the conversion of starch by enzymatic activity. Both can cause problems, including clouding the glass and clogging the joints. 

 

 

STABLE SYMBOL

The hourglass icon appears during measurement and disappears when the measurement value has stabilized

POCKET-POCKET DESIGN

Compact size ideal for field measurements 

OPERATION WITH JUST 1 BUTTON

All measuring and calibration activities are done with just a single button.

 

 

 

 

FLAT GLASS ELECTRODE HEAD

Designed to measure pH directly and prevent solid residue from sticking to the surface.

FABRIC JOINTS

Helps eliminate clogging caused by solids, which causes slow and unstable readings.

Simply pull the joint out 3 mm (1/8”) to expose the new joint surface for faster and more consistent readings.

ELECTRODE BODY MADE OF TITAN

Helps protect electrodes from breakage. With its roughness and elasticity, titanium acts as an electronic shield protecting the electrode from electrical interference or moisture.

 
 

 

 

 

 

CR2032 Li-ion battery

 

– The device uses 1 CR2032 Li-ion battery providing up to 1000 hours of continuous use (500 hours if Bluetooth is turned on)

 

– The battery icon will flash when low so you never miss a measurement.

 

– Batteries are easy to find at supermarkets, grocery stores or bookstores...

 

 

 

 

 

 

SUPPLIED COMPLETE SET WITHOUT PURCHASING ANYTHING ADDITIONAL

– Beer-specific cleaning solution packs are designed to keep your electrode free of yeast and sugar buildup. This concentrated combination of cleaning agents quickly and effectively cleans the meter so it stays in optimal condition by stirring to dissolve dirt in the water. Do not scrub as this will scratch the bulb. Measure sensor and then use a paper towel to absorb excess water (do not clean).

– pH4.01 and 7.01 machine calibration solution package

– Electrode preservation solution

– Convenient storage box

YouTube video
PINE NUMBER KY ARTICLE

pH

The scale

0.00 to 12.00 pH

mV*: pH/mV conversion

Resolution

0.01 or 0.1 pH

mV*: 0.1 or 1 mV

Accuracy

±0.05 pH

Calibration

Maximum 3 or 4 points*

Automatically accepts Hanna standard buffers (pH 1.68*, 4.01, 7.01, 10.01) or NIST (pH 1.68*, 4.01. 6.86, 9.18)

Heat compensation

Automatic ATC or Manual (MTC)*

TEMPERATURE

The scale**

0.0 to 80.0oC (32.0 to 176.0oF)

Resolution

0.1oC; 0.1oF

Accuracy

±0.5oC; ±0.9oF

ELECTRODE

Body material

Titan

Glass

Low Temperature (LT)

Joint

Fabric

Reference cell

Dual, Ag/AgCl

Electrolyte

Gel

Head/Shape

Plane

Outside diameter

12.7 mm (0.5”)

Length

110 mm (4.3”)

OTHER SPECIFICATIONS

Automatically shutdown

8 minutes, 60 minutes or no activation

The battery

3V Lithium – CR2032

Battery life

Approximately 1000 hours (500 hours if Bluetooth is enabled)

Environment

0 to 50oC (32 to 122oF)

Protection standard

IP65

Size/volume

51 x 185 x 21mm / 60g

GUARANTEE

6 months for the machine and 3 months for the electrodes

(for products with intact tags and warranty card)

SUPPLY INCLUDED

Measuring machine HI9810312

– The electrode is fixed to the body of the device and cannot be removed

– 2 packets of standard solution pH 4.01 HI70004, 20 mL

– 2 packets of standard solution pH 7.01 HI70007, 20 mL

– 2 packets of solution wash specialized electrode for beer residue HI700682, 20mL

- Solution preserve HI9072 electrode, 13 mL

– 3V Lithium battery – CR2032 (in the device)

- Warranty

– Product quality certification

- User manual

– Paper container

(Each packet of solution can only be used once)

Note

*Available in the Hanna Lab app

** Measurement outside the allowed temperature range may damage the gel electrolyte and is void of warranty.

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.