The HI5412 is a glass body, refillable, double junction half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and calomel reference.
Use with ion selective electrodes, titrations, and general applications with temperatures ranging from -5 to 60oC
Half-cell electrode
Caloric reference
Single ceramic joint
Hanna Instruments offers a line of pH electrodes designed for a variety of applications. The type of glass used for the pH sensor, bulb shape, body material, type of junction, type of reference, and electrolyte used are among the design considerations.
The HI5412 has a glass body, single ceramic junction, calomel reference and is refillable with 3.5M KCl.
Glass body
The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and can be easily cleaned. The glass body also allows for rapid heat transfer to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The reference potential is stabilized more quickly than equilibrium.
Single ceramic joint
The junction, also known as a salt bridge, is an essential component of the electrical circuit. The movement of ions must flow through the junction for a stable value. The external reference has a single ceramic frit. The ceramic is a porous material that can be easily fused to the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 µl/hour. Other types of junctions are available with higher flow rates and are made of different materials.
Refillable electrolysis
The HI5412 is a refillable probe. Since it is a double junction pH electrode, the fill solution is the HI7082 3.5M KCl. This solution does not contain silver as with single junction electrodes. The absence of silver prevents silver precipitates from forming at the junction and clogging. Clogging of the junction will result in drifty and erratic readings.
4mm connector
The HI5412 uses a 4 mm banana connector. This connector easily attaches to any meter with a reference input. Other connectors include DIN, screw type, T-type, and 3.5mm. Each meter typically has a unique connector and cannot be interchanged.
SPECIFICATIONS
Body material |
Glass |
Reference |
Single, Hg/Hg₂Cl₂ |
Splice/Line Speed |
ceramic, single/15-20 μL/h |
electrolysis |
3.5M KCl |
Maximum pressure |
0.1 bar |
Diameter |
12mm |
Body length/total |
120mm / 175.5mm |
Operating temperature |
-5 to 60°C (23 to 140°F) |
Cable |
1 m (3.3') |
Connect |
banana |
Guarantee |
06 months |
Application |
General purpose, titration |