Semiki logo
HOTLINE: +84 979761016
0

Cart

No products in the cart.

Continue shopping
Home / Shop / ORP Calibration Solution 240 mV, 250mL HI7021M
Product portfolio

ORP Calibration Solution 240 mV, 250mL HI7021M

Producer:
SKU: HANNA-HI7021M Category:

– ORP standard solution at 240mV

- Accuracy ±10mV @25°C

– Actual pH value table according to temperature is printed on the bottle body

– Long shelf life.

Supplied with MSDS and COA file format

WHAT IS ORP STANDARD SOLUTION?

HI7021M is a 240mV ORP standard solution used to test the performance of ORP electrodes. When the ORP electrode is placed in this solution, the reading obtained should be within ±10mV of 240mV @25°C. This solution allows the user to quickly check whether the ORP electrodes in use are reading accurately. As a diagnostic tool, the user can then decide whether the ORP electrode needs cleaning and conditioning. The standards are produced in Hanna's state-of-the-art manufacturing facility using pure chemicals in a temperature-controlled environment.

SPECIFICATIONS

Accuracy @25oC

240 ± 10mV

Specifications

– 500mL plastic bottle with dark gray label

– Yellow solution.

Using

– Pour enough calibration solution into a clean plastic cup so that the ORP electrode/sensor/junction is completely submerged in the calibration solution.

– Calibration: According to the instructions for use of the electrode or meter.

– Check accuracy: To put the device in measuring mode, immerse the electrode in the solution, the device will read out the measurement result in value 240 ± 10mV is normal. If the value is outside this range, treat the electrode with oxidizing or reducing solution, or the electrode may be damaged, contact HANNA technical support 028.39260.457 for support.

Methods of preservation

– After use, cover and store at room temperature, away from direct sunlight

– Do not dilute or add any chemicals to the solution.

– Always use fresh solution for each calibration

– ABSOLUTELY do not pour used solution back into the bottle.

Used for measuring machines

Any ORP meter that can be calibrated at 240mV

Certificate of Analysis (COA)

Have 

MSDS

Have 

Guarantee

- Are not

– Expiry date 1 year

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.