Semiki logo
HOTLINE: +84 979761016
0

Cart

No products in the cart.

Continue shopping
Home / Shop / General Purpose Electrode Cleaning Solution, 20mL Pack (25 packs) HI700601P
Product portfolio

General Purpose Electrode Cleaning Solution, 20mL Pack (25 packs) HI700601P

Producer:
SKU: HANNA-HI700601P Category:

– General electrode cleaning solution for many common applications.

– Each package is for single use, ensuring freshness.

– Electrode rinsing is a quick and effective routine that should be performed regularly as a preventative measure against using dirty electrodes and to ensure that the junction does not become clogged.

– Simply immerse the electrode in the cleaning solution for 15 to 20 minutes and stir. Helps to quickly remove impurities and residues remaining on the electrode surface.

– More thorough cleaning for longer electrode life.

– Can be used for all types of electrodes

WHY IS IT NECESSARY TO CLEAN pH AND ORP ELECTRODES REGULARLY?

The most common cause of measurement inaccuracies is unclean or improperly cleaned electrodes. This is important to note, as during calibration the meter will assume that the electrodes are clean and the calibration curve generated during calibration will remain a valid reference comparison until the next calibration. pH meters on the market today will allow for a voltage offset of approximately ± 60 mV. Deviation from 0 mV is unusual but ideally should not be greater than ± 30 mV. The calibration process compensates for the change in voltage offset. If the mV offset continues to drift and the meter is calibrated with a dirty electrode, inaccurate results will result.

When measuring frequently, molecules can contaminate the electrode tip. Using the wrong solution or an expired solution can affect the results.

The instrument can calibrate even if the electrode tip is dirty due to improper cleaning before calibration. If the solution is contaminated, the calibration will be invalid and the results will be inaccurate.

Properly cleaning the electrode with fresh solution will ensure the electrode tip gives accurate results and more accurate calibration.

Cleaning the electrodes should be a routine practice as a preventative measure against situations that may arise when calibrating with dirty electrodes and ensuring that the junctions do not become clogged. Simply soaking the electrodes in a specialized cleaning solution for about 15-20 minutes will dissolve any minerals or other coatings.

Use a Specialized Electrode Cleaning Solution for your measurement environment for best results.

List of specialized cleaning solutions: https://hannavietnam.com/detailcate/dung-dich-rua-dien-cuc-54

YouTube video

HI7061L

Specifications

– 20mL pack

– Quantity: 25 packs

– Colorless solution: The solution does not contain any dyes that could yellow or stain the electrode junction or reference cell.

Using

– Cut the mouth of 1 cleaning solution packet.

– Soak the electrode in the cleaning solution for about 15-20 minutes, then stir gently to dissolve the dirt into the solution.

– ABSOLUTELY do not scrub or scratch the pH or ORP bulb (sensor).

– The electrode SHOULD be washed immediately after each measurement.

– For pH or ORP electrode is too dirty or has not been used for a long time, after washing the electrode, Soak in preservative solution for at least 1 hour or overnight to reactivate. Then recalibrate.

Methods of preservation

– After use, store remaining packets at room temperature, away from direct sunlight.

– Do not dilute or add any chemicals to the solution.

– Always use fresh solution.

– NEVER pour used solution back into the package.

Used for measuring machines

Any meter on the market

Certificate of Analysis (COA)

Are not

MSDS

Have

Guarantee

Are not

Use a Specialized Electrode Cleaning Solution for your measurement environment for best results.

List of specialized cleaning solutions: https://hannavietnam.com/detailcate/dung-dich-rua-dien-cuc-54

YouTube video

HI7061L

Specifications

– 20mL pack

– Quantity: 25 packs

– Colorless solution: The solution does not contain any dyes that could yellow or stain the electrode junction or reference cell.

Using

– Cut the mouth of 1 cleaning solution packet.

– Soak the electrode in the cleaning solution for about 15-20 minutes, then stir gently to dissolve the dirt into the solution.

– ABSOLUTELY do not scrub or scratch the pH or ORP bulb (sensor).

– The electrode SHOULD be washed immediately after each measurement.

– For pH or ORP electrode is too dirty or has not been used for a long time, after washing the electrode, Soak in preservative solution for at least 1 hour or overnight to reactivate. Then recalibrate.

Methods of preservation

– After use, store remaining packets at room temperature, away from direct sunlight.

– Do not dilute or add any chemicals to the solution.

– Always use fresh solution.

– NEVER pour used solution back into the package.

Used for measuring machines

Any meter on the market

Certificate of Analysis (COA)

Are not

MSDS

Have

Guarantee

Are not

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.