Force and mechanical measuring equipment
– Ultra thin, compact, lightweight design
– Advanced touch keyboard
– Can be handheld, tabletop, or wall mounted.
– HI2030 is a meter with EC/TDS electrode
– Automatic data recording
– USB
– HI2030 can measure pH or dissolved oxygen (DO) when purchasing an additional pH or DO probe to connect
WALL MOUNTED DESIGN
Edge® Extremely flexible, can be used in many different applications such as wall-mounted, desktop or handheld.
SUPER THIN, COMPACT DESIGN
With a thickness of only 12mm and weight of only 250g
STURDY DESKTOP DESIGN
Edge® Equipped with an electrode holder and swivel table to charge and hold the Edge securely at the optimal viewing angle.
DIGITAL ELECTRODES
The edge electrode is considered an advanced product with an integrated microchip that has stored calibration information that can be extracted when power is plugged into the machine. The digital electrode is also equipped with a 3.5 mm jack that can be easily attached to the device
CHECK THE SENSOR
When using Hanna electrodes equipped with a matching pin, edge continuously checks the impedance of the pH electrodes to signal in case the glass electrode breaks. During calibration, the “Sensor Check” will check the condition of the connections. Reference joints are also evaluated and reported on the screen.
3.5mm JACK
The 3.5mm round plug makes it easier to remove and install the electrode, avoiding the case of accidentally breaking the pins.
TWO USB CONNECTOR PORTS
Edge includes a standard USB port for exporting data to a flash drive
A second micro USB port for connecting to a computer for data output and for charging the edge when the charging dock is not available.
AUTOMATIC DATA RECORDING
Edge allows storing up to 1000 data records. Settable data are value, GLP data, date and time.
TWO MODES OF OPERATION
– Basic: Edge reduces some features to make the device operate more simply.
– Standard: users can change these features.
SPECIFICATIONS
pH – When attaching the HI11310 pH electrode |
|
The scale |
-2,000 to 16,000 pH, -2.00 arrive 16.00 pH |
Resolution |
0.001 pH, 0.01 pH |
Accuracy |
±0.002 pH, ±0.01 pH |
Calibration |
1 to 5 points |
Benchmark |
1.68, 10.01, 12.45, 4.01, 6.86, 7.01, 9.18, 2 custom buffers |
Heat compensation |
ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F* |
EC (Conductivity) – When attached HI763100 EC/TDS electrode |
|
The scale |
0.00 to 29.99 μS/cm, 30.0 arrive 299.9 μS/cm, 300 arrive 2999 μS/cm 3.00 arrive 29.99 mS/cm, 30.0 arrive 200.0 mS/cm, to 500.0 mS/cm (absolute EC)** |
Resolution |
0.01 μS/cm, 0.1 μS/cm, 1 μS/cm 0.01 mS/cm, 0.1 mS/cm |
Accuracy |
±1% measurement result (±0.05 μS or 1 number whichever is greater) |
Calibration |
1 offset reference point (0.00 μS/cm in air) 1 benchmark at 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm |
Heat compensation |
ATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC |
TDS (Total Dissolved Solids) – When attached HI763100 EC/TDS electrode |
|
The scale |
0.00 to 14.99 ppm (mg/L), 15.0 arrive 149.9 ppm (mg/L), 150 arrive 1499 ppm (mg/L) 1.50 arrive 14.99 g/L, 15.0 arrive 100.0 g/L, to 400.0 g/L (absolute TDS)** with a conversion factor of 0.80 |
Resolution |
0.01 ppm, 0.1 ppm, 1 ppm 0.01 g/L, 0.1 g/L |
Accuracy |
±1% measurement result (±0.03 ppm or 1 number which is greater) |
Calibration |
through EC calibration |
Conversion factor |
0.40 to 0.80 |
SALINITY (NaCl) – When attached HI763100 EC/TDS electrode |
|
The scale |
0.0 arrive 400.0 %NaCl 2.00 arrive 42.00 PSUs 0.0 to 80.0 g/L |
Resolution |
0.1% NaCl 0.01 PSUs 0.01 g/L |
Accuracy |
±1% measurement results |
Calibration |
1 point with HI7037L 100% NaCl standard solution (outside the EC calibration scale) |
DISSOLVED OXYGEN (DO) – When attaching the HI764080 DO electrode |
|
The scale |
0.00 arrive 45.00 ppm (mg/L) 0.0 to 300.0% saturation |
Resolution |
0.01 ppm 0.1% saturation |
Accuracy |
±1 digit and ±1.5% measurement results |
Calibration |
1 or 2 points 0% (HI7040 solution) and 100% (air) |
Heat compensation |
ATC: 0 arrive 50 ºC; 32.0 arrive 122.0 °F |
Salinity compensation |
0 arrive 40 g/L (with 1g/L resolution) |
Altitude compensation |
-500 arrive 4000 m (with 100m resolution) |
TEMPERATURE |
|
The scale |
-20.0 to 120.0ºC, -4.0 arrive 248.0°F |
Resolution |
0.1°C, 0.1°F |
Accuracy |
±0.5°C, ±1.0°F |
OTHER SPECIFICATIONS |
|
pH electrode EC/TDS/Temperature electrode DO electrode |
any digital electrode with a 3.5mm jack |
GLP |
Have |
Record data |
up to 1000 records (400 in basic mode) – BHandwritten upon request (maximum 200 copies) – Manually based on stability (maximum 200 copies) – Record by interval*** (maximum 600 samples; 100 copies) |
Connect |
1 USB port for charging and connecting to computer, 1 port for storage |
Environment |
0 to 50°C (32 to 122°F), RH max 95% non-condensing |
The battery |
Rechargeable battery with 8 hours of continuous use |
Electricity supply |
5 VDC adapter (included) |
Size |
202 x 140 x 12.7mm |
Mass |
250 g |
Guarantee |
12 months for machine and 6 months for electrodes (for products with intact tags and warranty card) |
Supply includes |
– Measuring machine HI2030 + HI2030-01: 115V + HI2030-02: 230V – HI763100 EC/TDS/Salinity Electrode Plastic body with integrated temperature sensor, 3.5mm port – 4 Packets of solution conductivity standard 1413 μS/cm – 2 Packets of solution conductivity standard 12880 μS/cm – 2 Packets of solution Conductivity standard 5000 μS/cm – 2 packs of electrode cleaning solution - USB cable – Electrode holder and charging base – Wall mount – 5 VDC adapter - User manual - Warranty – Quality certificate for machine and electrodes - Containers |
Note |
* The temperature limit will be reduced to the actual limit of the probe ** does not activate the temperature compensation function *** only in Standard mode (Data recording) |
Accessories purchased separately |
– HI764080: Dissolved oxygen electrode – HI11310: pH electrode |