Force and mechanical measuring equipment
– Slim and light tablet design
– pH/ORP/Temperature meter (ORP electrode purchased separately)
– Multi-function: handheld, desktop and wall mounted
– Large screen up to 5.5 inches
– CAL Check self-checks electrodes
– Automatic data recording
– USB
– The meter comes with a digital electrode and full set of accessories for pH measurement.
– HI2020 can measure EC, TDS or dissolved oxygen (DO) with the purchase of an additional EC or DO probe
+ HI2020-01: uses 115V electricity (USA)
+ HI2020-02: Uses 230V electricity (Vietnam)
+ HI2020-03: Meter only, no accessories such as adapters, electrodes, etc.
WALL MOUNTED DESIGN
Edge® Extremely flexible, can be used in many different applications such as wall-mounted, desktop or handheld.
SUPER THIN, COMPACT, HAND-HELD DESIGN
With a thickness of only 12mm and weight of only 250g
STURDY DESKTOP DESIGN
Edge® Equipped with an electrode holder and swivel table to charge and hold the Edge securely at the optimal viewing angle.
DIGITAL ELECTRODES
The edge electrode is considered an advanced product with an integrated microchip that has stored calibration information that can be extracted when power is plugged into the machine. The digital electrode is also equipped with a 3.5 mm jack that can be easily attached to the device
CHECK THE SENSOR
When using Hanna electrodes equipped with a matching pin, edge continuously checks the impedance of the pH electrodes to signal in case the glass electrode breaks. During calibration, the “Sensor Check” will check the condition of the connections. Reference joints are also evaluated and reported on the screen.
3.5mm JACK
The 3.5mm round plug makes it easier to remove and install the electrode, avoiding the case of accidentally breaking the pins.
TWO USB CONNECTOR PORTS
Edge includes a standard USB port for exporting data to a flash drive
A second micro USB port for connecting to a computer for data output and for charging the edge when the charging dock is not available.
AUTOMATIC DATA RECORDING
Edge allows storing up to 1000 data records. Settable data are value, GLP data, date and time.
TWO MODES OF OPERATION
– Basic: Edge reduces some features to make the device operate more simply.
– Standard: users can change these features.
SPECIFICATIONS
pH |
|
The scale |
-2,000 to 16,000 pH, -2.00 arrive 16.00 pH |
Resolution |
0.001 pH, 0.01 pH |
Accuracy |
±0.002 pH, ±0.01 pH |
Calibration |
1 to 5 points |
Benchmark |
1.68, 10.01, 12.45, 4.01, 6.86, 7.01, 9.18, 2 custom buffers |
Heat compensation |
ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F* |
EC (Conductivity) – When attached HI763100 EC/TDS electrode |
|
The scale |
0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, to 500.0 mS/cm (absolute EC)** |
Resolution |
0.01 μS/cm, 0.1 μS/cm, 1 μS/cm 0.01 mS/cm, 0.1 mS/cm |
Accuracy |
±1% measurement result (±0.05 μS or 1 number whichever is greater) |
Calibration |
1 offset reference point (0.00 μS/cm in air) 1 benchmark at 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm |
Heat compensation |
ATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC |
TDS (Total Dissolved Solids) – When attached HI763100 EC/TDS electrode |
|
The scale |
0.00 to 14.99 ppm (mg/L), 15.0 arrive 149.9 ppm (mg/L), 150 arrive 1499 ppm (mg/L) 1.50 arrive 14.99 g/L, 15.0 arrive 100.0 g/L, to 400.0 g/L (absolute TDS)** with a conversion factor of 0.80 |
Resolution |
0.01 ppm, 0.1 ppm, 1 ppm 0.01 g/L, 0.1 g/L |
Accuracy |
±1% measurement result (±0.03 ppm or 1 number which is greater) |
Calibration |
through EC calibration |
Conversion factor |
0.40 to 0.80 |
SALINITY (NaCl) – When attaching the EC/TDS electrode HI763100 – BASIC MODE ONLY |
|
The scale |
0.0 arrive 400.0 %NaCl 2.00 arrive 42.00 PSUs 0.0 to 80.0 g/L |
Resolution |
0.1% NaCl 0.01 PSUs 0.01 g/L |
Accuracy |
±1% measurement results |
Calibration |
1 point with HI7037L 100% NaCl standard solution (outside the EC calibration scale) |
DISSOLVED OXYGEN (DO) – When attaching the HI764080 DO electrode |
|
The scale |
0.00 arrive 45.00 ppm (mg/L) 0.0 to 300.0% saturation |
Resolution |
0.01 ppm 0.1% saturation |
Accuracy |
±1 digit and ±1.5% measurement results |
Calibration |
1 or 2 points 0% (HI7040 solution) and 100% (air) |
Heat compensation |
ATC: 0 arrive 50 ºC; 32.0 arrive 122.0 °F |
Salinity compensation |
0 arrive 40 g/L (with 1g/L resolution) |
Altitude compensation |
-500 arrive 4000 m (with 100m resolution) |
TEMPERATURE |
|
The scale |
-20.0 to 120.0ºC, -4.0 arrive 248.0°F |
Resolution |
0.1°C, 0.1°F |
Accuracy |
±0.5°C, ±1.0°F |
OTHER SPECIFICATIONS |
|
pH electrode |
any digital electrode with a 3.5mm jack |
GLP |
Have |
Record data |
up to 1000 records (400 in basic mode) – By hand on request (maximum 200 copies) – Manually based on stability (maximum 200 copies) – Record by interval*** (maximum 600 samples; 100 copies) |
Connect |
1 USB port for charging and connecting to computer, 1 port for storage |
Environment |
0 to 50°C (32 to 122°F), RH max 95% non-condensing |
The battery |
Rechargeable battery with 8 hours of continuous use |
Electricity supply |
5 VDC adapter (included) |
Size |
202 x 140 x 12.7mm |
Mass |
250 g |
Guarantee |
12 months for machine and 6 months for electrodes (for products with intact tags and warranty card) |
Supply includes |
– Measuring machine HI2020 + HI2020-01: 115V + HI2020-02: 230V – pHHI11310 electrode Glass body with built-in temperature sensor, 3.5mm port – Solution package pH standard 4.01; pH 7.01 and pH 10.01 – Electrode cleaning solution package - USB cable – Electrode holder and charging base – Wall mount – 5 VDC adapter - User manual - Warranty – Quality certificate for machine and electrodes - Containers |
Note |
* The temperature limit will be reduced to the actual limit of the probe ** does not activate the temperature compensation function *** only in Standard mode (Data recording) |
Accessories purchased separately |
– HI764080: Dissolved oxygen electrode – HI763100: EC/TDS/Salinity Electrode |