Force and mechanical measuring equipment
– Slim and light tablet design
– Measure EC/TDS/Salinity with just 1 4-ring conductivity probe
– Multi-function: handheld, desktop and wall mounted
– Touch keyboard
– Large screen up to 5.5 inches
– The meter comes with digital electrodes and all necessary accessories.
– CAL Check self-checks electrodes
– Automatic data recording
+ HI2003-01: uses 115V electricity (USA)
+ HI2003-02: Uses 230V electricity (Vietnam)
+ HI2003-03: Meter only, no accessories such as adapters, electrodes, etc.
MACHINE COMES WITH DIGITAL pH ELECTRODES
The probe has a built-in microchip that stores calibration information that can be extracted when connected to the meter.
3.5mm ROUND PLUG
Disassembling the electrode is easier, avoiding accidentally breaking the pins.
HI763100 4-RING CONDUCTIVITY PROBE
With built-in temperature sensor for automatic temperature measurement.
The 4-ring technology allows for a wider measurement range than dual-pole probes which have limited amperage and can suffer from polarization effects. The HI763100 probe has a glass and PVDF body with a PEI (polyetherimide) jacket. Both materials have excellent resistance to many aggressive chemicals.
WALL MOUNTED DESIGN
Easy to observe from afar and save space
SUPER THIN, COMPACT, HAND-HELD DESIGN
With a thickness of only 12mm and weight of only 250g
STURDY DESKTOP DESIGN
Edge® Equipped with an electrode holder and swivel table to charge and hold the Edge securely at the optimal viewing angle.
CAPACITIVE TOUCH KEYBOARD
Edge is like a tablet with a modern, easy-to-select touch keyboard with a large area.
AUTOMATIC DATA RECORDING
edge allows storing up to 1000 data records. Settable data are values, GLP data, calibration date and time and can be reviewed at any time.
TWO MODES OF OPERATION
edge has 2 operating modes: Basic and Extended. In Basic mode, edge reduces some features to make the machine operate more simply. In Standard mode, users can change these features.
TWO USB CONNECTOR PORTS
1 for data export and 1 for connecting to a computer and for charging when the charging dock is not available.
PERFECT CHOICE WITH COMPLETE SET
– HI2003 meter
– HI763100 pH electrode with built-in temperature
– Conductivity calibration solution
– Electrode cleaning solution
– Electrode holder and charging base (tabletop)
– Wall mount (wall mounted)
- USB cable
– Adapter
SPECIFICATIONS
Conductivity (EC) |
|
The scale |
0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, to 500.0 mS/cm (absolute EC)** |
Resolution |
0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm |
Accuracy |
±1% value (±0.05 μS/cm or 1 digit, whichever is larger) |
Calibration |
Automatic at 1 point – 1 point offset (0.00 μS/cm in air) – 1 slope calibration point at 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm or 111.8 mS/cm |
Total Dissolved Solids (TDS) |
|
The scale |
0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (Absolute TDS)** |
Resolution |
0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
Accuracy |
±1% value (±0.03 ppm or 1 digit, whichever is greater) |
Calibration |
Together with EC calibration |
Conversion factor |
0.40 to 0.80 (default value is 0.50) |
SALINITY (NaCl) |
|
The scale |
0.0 to 400.0% NaCl, 2.00 to 42.00 PSU, 0.0 to 80.0 g/L* |
Resolution |
0.1% NaCl, 0.01 PSU, 0.01 g/L |
Accuracy |
±1% value |
TEMPERATURE |
|
The scale |
-20.0 to 120.0ºC, -4.0 to 248.0°F |
Resolution |
0.1°C, 0.1°F |
Accuracy |
±0.5°C, ±0.9°F |
OTHER SPECIFICATIONS |
|
Heat compensation |
Automatic from -5 to 100oC ,NoTC – selectable when measuring absolute conductivity |
Temperature coefficient of conductivity |
0.00 to 6.00%/oC |
GLP |
Have |
Record data |
up to 1000 records (400 in basic mode): Manual on demand (up to 200 records), Manual based on stability (up to 200 records), Interval recording (up to 600 samples; 100 records) |
Connect |
1 USB port for charging and connecting to computer, 1 port for storage |
Environment |
0 to 50°C (32 to 122°F), RH max 95% non-condensing |
The battery |
Rechargeable battery with 8 hours of continuous use |
Electricity supply |
5 VDC adapter (included) |
Size |
202 x 140 x 12.7mm |
Mass |
250 g |
Guarantee |
12 months for machine and 6 months for electrodes (for products with intact tags and warranty card) |
Supply includes |
– Measuring machine HI2003 + HI2003-01: 115V + HI2003-02: 230V – HI763100 EC/TDS/Salinity Electrode Plastic body with integrated temperature sensor, 3.5mm port – 4 Packets of solution conductivity standard 1413 μS/cm – 2 Packets of solution Conductivity standard 12880 μS/cm – 2 Packets of solution conductivity standard 5000 μS/cm – 2 packs of electrode cleaning solution - USB cable – Electrode holder and charging base – Wall mount – 5 VDC adapter - User manual - Warranty – Quality certificate for machine and electrodes - Containers |
Note |
*Basic mode only ** does not activate the temperature compensation function |