Semiki logo
HOTLINE: +84 979761016
0

Cart

No products in the cart.

Continue shopping
Home / Shop / Electronic industry measuring machine / Multi-channel data logger / Temperature and humidity recorder / GRAPHTEC GLT400 wireless signal acquisition device connected to PLC
Product portfolio

GRAPHTEC GLT400 wireless signal acquisition device connected to PLC

Producer:

GRAPHTEC GLT400 is a versatile data logger that can be used as an expansion unit and a stand-alone measurement such as for use in research and development, expanding new areas into manufacturing and production engineering , incorporated into control panels and devices, collects data from PLC via Modbus/TCP and as PC logger.
Three types of analog input terminals are available in the product line, selectable due to input type, and expandable from standard 20 channels to a maximum of 200 channels.
We can provide documentation on how to connect to PLCs and other devices using Modbus/TCP.

GRAPHTEC Japan 

Monitorless Data Logger
Model: GLT400 (Up to 10 units 200channel)

 

GRAPHTEC GLT400 is a multi-use data logger that can be used as an extension unit and a stand-alone measurement such as utilization at research and development, newly expanding the sector to production engineering and production, incorporation into control panels and devices, data acquisition from PLCs via Modbus/TCP, and as PC loggers.
Three types of analog input terminals are available in the lineup, which can be selected due to the input type, and can be expanded from the standard 20 channels to a maximum of 200 channels.
We can provide a document on how to connect to PLCs and other devices using Modbus/TCP.

Mount or embed in a system and remote monitoring by PC.

Modbus/TCP for PLC I/O channels. It can be used as additional I/Os.

● Transferring data to PLC via Modbus/TCP protocol
● DC Power only for -20 to +60 operation
● Supports WEB server, FTP server and FTP client network functions for remote monitoring and controlling.
● High Isolation inputs to ensure signals are not corrupted by noise from other channels
● Connect as a remote terminal unit of GL840

YouTube player

Enable to use as PC hosted data logger

Connection to PC via USB ,LAN and Wireless LAN.
Standalone or PC hosted data logger for R&D, Quality and Production

Connect as a remote terminal unit of GL840

Communications via Ethernet or Wireless LAN.*
(Expand up to 200 ch (incl.GLT400) per GL840 or
Up to 5 units of GLT400 can be connected to GL840 host) Setup and control from GL840 and captured data
can be stored on GL840 which is measured from GLT400.

Specifications:

Analog Input Terminal Capable of Multi-input

(common analog input terminal)

Voltage, temperature, and humidity can be selected for each input channel.
Use EU scaling for other measurement parameters.

Measure voltage

Supports wide operating range (from 20 mV to 100 V)

Measure temperature

  • Thermocouple:K, J, E, T, R, S, B, N, C (WRe5-26)
  • RTD: Pt100, JPt100,Pt1000 (IEC751)

Measure current (4 -20 mA)

Shunt resistor (250Ω) is available as an option.
Equipped with a dedicated 1-5V range for the measurement range

  • Shunt resistance 250Ω (B-551)
    Cannot use B-551 resistor with B-564SL input terminal
Shunt resistor

Measure humidity

A humidity sensor is available as an option.
Power for the sensor is also supplied from the main unit.
Equipped with a dedicated humidity range

  • Humidity sensor (B-530)
humidity sensor

Digital I/O port available

Digital I/O can be used by connecting an optional I/O cable.

  • Input/Output cable (B-513)
  • When connected as a remote terminal unit of GL840, this function cannot be used.
Input/Output cable

Logic/Pulse inputs (4 channels)

Logic : No-voltage contact (A contact, B contact, NO, NC) ,Open collector, Voltage input (HL decision)
Pulse : 3 types of selections (Rotation / Quantity count / Instantaneous) per channel

 

Alarm output (4Channels) & Signal input for external trigger (1Channel)

Start/Stop recording with external trigger.
Alarm output port (1 to 4) are set for each analog input channel.

Alarm output (4Channels) & Signal input for external trigger (1Channel)

Expandable Up to 200 Channels

By adding an analog input terminal and an terminal base, it can be expanded in 20ch increments from a min of 20ch to a max of 200ch.

The Measurement Data is Safely Stored in the Flash Memory

Standard 8GB built-in flash memory and SD card slot.

  • Internal memory: 8GB
  • SD card slot: Support SDHC and Max 32 GB
  • SD card cannot be used when the wireless LAN unit is used.
  • Max single file size is 2GB. (use Relay mode to extend recording)

Maintenance and calibration : 

► We also have calibration certificate attached ( optional )

► Please re-calibrate after use for a certain period through our purchase store.

Local Vietnam : SEMIKI Ins

 

DISTRIBUTED BY:

Semiki instrumentation Co., Ltd

Email: sales@semiki.com

Office tel: +84 28 2253 3522

~DOING OUR BEST FOR YOU~

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.