SOIL TESTER Field ready Fast operation Extensive measurement functions
Extensive measurement functions: choose the right measurement method for any application
− 4-pole method (Wenner's 4-pole method):
Measuring soil resistivity during grounding design survey
− 3-pole method:
Accurate measurement of earth resistance
− MEC function (Soil measurement with clamp):
Measure earth resistance without disconnecting the earth electrode
− 3-pole method uses 4-terminal measurement:
Measure ground resistance values of a few ohms or less
− 2 clamp method:
Measure earth resistance at multiple earthing points
− Low resistance measurement:
Check continuity after measuring earth resistance
Sample Number (Order Code)
FT6041: FT6041 with accessories included
FT6041-90: FT6041 with Z3210
FT6041-91: FT6041 with accessories included, also includes clamp sensors FT9847 and CT9848
FT6041-92 KIT: FT6041-91 with Z3210

HIOKI Japan 

Ground Resistance

EARTH TESTER

Model: FT6041 / FT6041-91

What does “grounding” mean?

Grounding means making an electrical connection between an electrical device or a building and the earth underfoot. Properly grounding equipment and buildings helps ensure safety by preventing electric shock and related accidents. It also helps prevent the occurrence of har-monics, equipment malfunctions, power outages, and other issues with power supply quality. During installation and maintenance, it's critical to make sure the ground resistance values of your grounding equipment conform to the values specified by applicable laws and standards

Pic.: HIOKI FT6041-91 EARTH TESTER Field-capable Fast-working Extensive measurement functionality

HIOKI EATH TESTER FT6041

Extensive measurement functionality: choose the right measurement method for any application

− 4-pole method (Wenner's 4-pole method):
Measure soil resistivity when surveying a grounding design

− 3-pole method:
Precisely measure ground resistance

− MEC (Measuring Earth with a Clamp) function:
Measure ground resistance without disconnecting ground electrodes

− 3-pole method using 4-terminal measurement:
Measure ground resistance values of several ohms or less

− 2-clamp method:
Measure grounding resistance at multiple grounds

− Low-resistance measurement:
Continuity test after ground resistance measurement

4-pole method

Measure soil resistivity when surveying a grounding design

Soil resistivity is measured as part of the grounding design process in advance of building design. Soil resistivity vary with each site's geo- logical properties. In this process, optimal ground locations as well as grounding electrode shapes, dimensions, and other characteristics are designed based on the assessment of soil resistivity.

MEC function

Measure ground resistance without disconnecting ground electrodes

This function augments the 3-pole method with current measure- ment using a clamp sensor. By measuring only current flowing to the grounding electrode you want to measure, you can avoid the effects of other grounds. This capability can significantly reduce man-hours spent on measurement work.

Model No. (Order Code)
FT6041 : FT6041 with included accessories
FT6041-90: FT6041 with Z3210
FT6041-91: FT6041 with included accessories, also includes clamp sensors FT9847 and CT9848
FT6041-92 KIT: FT6041-91 with Z3210

YouTube player

HIOKI Earth Tester FT6041 | intro

Specifications:

HIOKI FT6041
Included accessories Auxiliary Earthing Rod L9840 (2 piece set) ×2, Measurement Cable L9845-31 ×1, Measurement Cable L9845-33 ×1, Measurement Cable L9845-52 ×1, Measurement Cable L9841 ×1, Test Lead L9787 ×1, Earth Nets Module L9846 ×2, Carrying Case C0208 ×1, Carrying Case C0209 ×1, Protector ×1, LR6 Alkaline battery ×4, Instruction manual ×1, Operating precautions ×1

Maintenance and calibration : 

► We also have calibration certificate attached ( optional )

► Please re-calibrate after use for a certain period through our purchase store.

Local Vietnam : SEMIKI Ins

 

DISTRIBUTED BY:

Semiki instrumentation Co., Ltd

Email: sales@semiki.com

Office tel: +84 28 2253 3522

~DOING OUR BEST FOR YOU~

 

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.