Force and mechanical measuring equipment
Malcom RCX-V sensor
The RCX-V is a sensor that can be placed on the PCB to measure vibration. Check the furnace rail/conveyor to ensure the PCB is not subject to excessive vibration.
Measuring Range / Resolution / Accuracy:
±2.0g (1.0g=9.806 65m/s2) / 0.001g (1.0g=9.806 65m/s2) / ±0.005g (1.0g=9.806 65m/s2)
Vibration during reflow is measured by two sensors.
It can be easily understood by the measurement of gravitational acceleration and each X, Y, Z is shown by profile.
● Vibration level profile can be measured in heated state.
● Gravitational acceleration is measured by two sensors.
● Measurement results are displayed in the profile.
● Analysis of welding errors caused by vibration
● Vibration changes due to wind speed setting
● Check the device status due to aging.
The RCX-V is a sensor that can be placed on the PCB to measure the vibration.
Verify the oven's rails/conveyor to ensure the PCB isn't being exposed to excessive vibration.
Reflow Checker Memory Unit withSubstrateVibrationMonitor
Model: RCX-V
● Vibration level profile measurement is possible in the heated state.
● The gravitational acceleration is measured by two sensors.
● The measurement results are displayed in a profile.
● Analysis of soldering failure due to vibration
● Change in vibration due to wind speed setting
● Inspection of equipment status due to aging.
Vibration during reflow heating is measured by two sensors.
It is easy to understand by gravity acceleration measurement, and each of X, Y, Z is displayed with the profile.
Measuring range / Resolution /Accuracy:
±2.0g (1.0g=9.806 65m/s2) / 0.001g (1.0g=9.806 65m/s2) / ±0.005g (1.0g=9.806 65m/s2)
Max. measuring time : Approx. 3 hours (Ni-MH battery
Sampling time (sec.) : 0.05 , 0.1 , 0.2 , 0.5 , 1.0 , 2.0 , 4.0 , 8.0
Arbitrarily set up possible (synchronized to RCM-S)
Power supply: Supplied from RCM-S main unit, AAA batteries x 3pcs.
Outer dimensions:
Main unit: 221 (D) x 50 (W) x 18 (H) mm (with RCM-S main unit, Sensors are not included)
Sensor: 45 (D) x 35 (W) x 19 (H) mm
Heat resistant case: 360 (D) x 65 (W) x 25 (H) mm
Weight: Approx. 800g
Accessories: including RCM-S main unit & batteries, Conveyor attachment system is not included.
Maintenance and calibration :
► We also have calibration certificate attached ( optional )
► Please re-calibrate after use for a certain period through our purchase store.
DISTRIBUTED BY:
Semiki instrumentation Co., Ltd
Email: sales@semiki.com
Office tel: +84 28 2253 3522
~DOING OUR BEST FOR YOU~