Semiki logo
HOTLINE: +84 979761016
0

Cart

No products in the cart.

Continue shopping
Home / Shop / Lab equipment / Hanna experimental measuring equipment / HI932 Automatic Voltage Titrator
Product portfolio

HI932 Automatic Voltage Titrator

Producer:
SKU: HANNA-HI932 Category:

– Perform many acid-base, redox, complex, precipitate, and anhydrous reactions

– Back titration and determination of reagent concentration. 

– No additional programming upgrades required.

– USB.

– Support for technical consulting and product lifetime methods.

– Unprecedented 40,000-step dosing pump for small volumes of titrant

– Achieve very precise endpoints for greater consistency.

– Store up to 100 methods.

         + HI932C1-02: 1 analog board

         + HI932C2-02: 2 analog boards

Old model New generation model

HI901C1

HI931 (potentiometric titration, 1 analog board)

HI902CX

HI932 (potentiometric titration, 1 or 2 analog boards, can be connected to HI921)

HI903

HI933 (KF volumetric titration)

HI904

HI934 (KF coulometric titration)

 

YouTube video

COMPACT DESIGN

 

COMPACT, MODERN DESIGN

More compact than the old design 50%.

MOST OF THE MACHINE'S PLASTIC IS MADE FROM CYCOLOY 

Harder, more durable, more chemically resistant and less likely to stain than ABS.

THE PUMP REMAIN THE SAME 40,000 STEPS FROM THE HI90X, BUT WITH AN ADDED JOINT 

Combined with a tighter burret, the motor is improved for quieter operation

 

 

ELECTRODE HOLDER AND STIRRING ARMS

 

SMARTER STIRRING ARMS

Built-in removable stirring paddle Speed control for more consistent stirring.

ELECTRODE HOLDER AT THE REAR OF THE MACHINE

Contains more electrodes, is more sturdy, flexible, easy to disassemble and limits collision between electrodes.

– Accommodates up to 3 electrodes, 4 tubes and 1 temperature probe.

The angled stand and removable stirrer keep it out of the way when titrating small volumes.

Can be used for multiple electrodes of different sizes as needed by changing the electrode guide withoutThere is no need to move the electrodes around, align the tube best for titration with swivel stand.

With a more compact design, the electrode holder is attached directly to the titration body. Push-release button for simple height control and use of larger cups when needed.

 

 

 

DYNAMIC PUMP

The dynamic pumping feature helps users optimize titration time while still maintaining high accuracy, based on voltage changes to adjust the amount of reagent injected accordingly. When far from the end point, the machine will pump more reagent to shorten the time. When near the end point, the machine will pump less and less to ensure the accuracy of the process.

DETERMINING SIGNAL STABILITY (signal stability)

This feature will monitor and determine signal stability before proceeding with the next pump. This feature will ensure the measured results are always accurate throughout the titration process.

DETERMINING THE EQUIVALENCE POINT OF THE REACTION (equivalence endpoint)

Reaction equivalence point determination is a perfect feature for titrating reactions where the end point of the reaction is unknown, based on determining the largest mV signal increase during a single injection.

ADD REAGENT AUTOMATICALLY

A peristaltic pump can be programmed to dispense volumetric reagents before titration or direct measurement. This helps achieve consistent and accurate results and prevents operational errors such as incorrect volumes or forgotten reagent additions. Peristaltic pumps can also be used for post-analytical aspiration.

 

 

 

 

 

 

Identify multiple equivalence points

HI932 Can determine up to 5 equivalence points in one titration, meeting most requirements of typical methods in the food, textile and pharmaceutical industries.

Determine the order of the titration method

The HI932 can be set up to perform two consecutive titrations on the same sample or perform back titrations for slow reactions.

Many types of titration

Depending on the type of connected electrode, the device can titrate acid-base, redox, complex, precipitate, anhydrous, etc.

SAFE DESIGN: TIn the event of a reagent leak, an external drain system protects the connections on the back of the meter and the internal prevents any liquid from reaching the internal electronics.

 

 

BURETTE AND PUMP

 

EASY TO REPLACE BURETTE

With the Clip-lock burette feature, it only takes a few seconds to replace a new burette into the pump, saving time and minimizing reagent contamination.

DIVERSE BURETTE SIZES

HI932 will be supplied with a 25mL burette

Additionally, the HI932 can use 5mL, 10mL, or 50mL burettes (purchased separately). Each burette consists of a glass cylinder and PTEF plastic plunger.

PIPE AND CYLINDER HAVE HIGH CHEMICAL DURABILITY

– The reagent distribution pipe system is made from flexible and highly chemically resistant material PTFE

– The cylinder is equipped with a polyurethane light cover to protect light-sensitive reagents.

HIGH PRECISION PUMP

Extremely high resolution 40,000-step piston pump capable of pumping reagent volumes as small as 0.125µL.

The pump has an additional option that can be combined with a peristaltic pump to pump more distilled water or chemicals into the sample cup.

 

 

 

 

 

DISPLAY

 

HIGH CONTRAST SCREEN

Large LCD screen, diverse colors, clear image display, helping users easily observe and operate the machine.

DETAILED GRAPH

Real-time graphs are displayed throughout the titration process, which is useful in cases where a new method is being tried or an old method needs to be adjusted.

EASILY SWITCH BETWEEN INTERFACE SCREEN

On-screen virtual selection keys allow users to easily switch between the home screen, real-time graphs, and menus on the fly.

 

 

 

 

DATA SAVING

 

Highly customizable reports.

Users can optionally adjust the data to be reported based on their work requirements.

Easily manage GLP information

All GLP information can be customized in different templates: sample information, company, operator, date, month...

Efficient data conversion

Data can be transferred via USB or computer easily via USB cable and HI900PC software.

The USB port is used to transfer reports, titration methods, and upgrade the instrument's software.
 

 

 

 

CONNECTIVITY FEATURES

Multi-function device

HI932 Can be used as a titrator, pH meter, ORP meter, and ISE meter, helping to save laboratory space, analyzing multiple parameters in just one sample.

Connect Printer and Analytical Balance

Analytical balances with RS232 output can transfer sample weight directly to the meter.

Titration reports can be printed directly from the titrator to the connected printer.

 

ANALYTICAL METHODS

 

The method is highly customizable

HI93X can contain up to 100 methods, each of which can be customized and optimized to suit the requirements of each different reaction during use.

Supports method setup

Hanna's technical department is always willing to assist customers in answering any questions about using the machine and setting up titration methods.

Supports multiple titration method packages

Hanna has many method packages to meet many different industries such as food, beverage, textile dyeing, wine production and pharmaceuticals. If you have any needs, please contact your local company for more detailed support.

Compatible with standard method sets.

Hanna experts can set up and customize titration methods based on standard method sets such as ISO, ASTM, AOAC, AOCS, EPA.

MAIN APPLICATION

    – Redox reaction

    – Acid-base reaction

    – Precipitation reaction

    – Complex formation reaction

    – Reaction to anhydrous medium

Video

YouTube video

SPECIFICATIONS

Type of analysis

Standard titration (standardization, default pH/mV, pH/mV equivalence point)

Back titration

Read value directly

Determine the end point

default mV

Default pH

to 5 pH equivalent points (1st or 2nd derivative)

to 5 points is equivalent to mV (1st or 2nd derivative)

BURET

Size

5, 10, 25 and 50mL

Resolution

0.001 mL

Pump speed

0.3 mL to 2 x burette volume per minute

Accuracy

±0.005 mL (5mL burette)

±0.010 mL (burette 10mL)

±0.025 mL (burette 25mL)

±0.050 mL (burette 50mL)

STIRRING SYSTEM

The scale

200 to 2500 rpm

Resolution

100 rpm

pH

The scale

-2.0 to 20.0 pH; -2.00 ― 20.00 pH; -2,000 ― 20,000 pH

Resolution

0.1 pH / 0.01 pH

Accuracy

(@25ºC/77ºF)

±0.001 pH

Calibration

Maximum 5 points (select from 8 standard buffers and 5 optional buffers).

Heat compensation

Automatic from -5.0 to 105.0°C; 23.0 to 221.0°F

mV

The scale

-2000.0 to 2000.0 mV

Resolution

0.1 mV

Accuracy (@25ºC/77ºF)

±0.1 mV

Calibration

1 offset point

ISE

The scale

1 x 10⁻⁶ to 9.99 x 10¹⁰ concentration

Resolution

first; 0.1; 0.01 concentration

Accuracy

±0.5% with valence atom I; ±1% with valence atom II

Calibration

Automatic, up to 5-point calibration, 7 fixed standard solutions available (0.01, 0.1, 1, 10, 100, 1000, 10000 optional according to concentration) and 5 custom solutions

TEMPERATURE

The scale

-5.0 ― 105.0°C; 23.0 ― 221.0°F; 268.2 ― 378.2K

Resolution

0.1°C; 0.1°F; 0.1K

Accuracy

(@25ºC/77ºF)

±0.1°C; ±0.2°F; ±0.1K, excluding electrode error

DATA SAVING

Method

Up to 100 methods (standard and user options)

Record data

Up to 100 titration and pH/mV/ISE reports

CONNECT

Measure

BNC port (pH, ORP, ISE half-cell and combined)

4 mm Banana port (reference electrode)

RCA port (temperature electrode)

Port 6 – battery (paddle)

Peripheral

6-pin DIN port (external PC keyboard)

DB-25 port (printer)

USB standard B port (PC port)

Port 6 – battery (paddle)

OTHER SPECIFICATIONS

Electrode holder

Reagent/titrant tube (4 holes)

3 x 12mm electrodes (3 holes)

Temperature probe

Stirring paddle

Analog board

2

Dosing pump

2

Burette included

1 (25mL)

Burette volume

5, 10, 25 and 50mL

Burette resolution

1/40000

Display resolution

0.001 mL

Pump precision

±0.1% total burette volume

Identify Burette

Automatically detects burette volume when attached to the pump

GLP standards

Stores all information about the titrator, user, sample name, and measurement method.

Method link

Have

Back titration

Have

HI932 compatible

Have

Display

5.7” color LCD screen (320 x 240 pixels)

Language

English, Spanish, Portuguese.

Electricity supply

100-240 VAC, 50/60Hz

-01: US plug (type A);

-02: European plug (type C)

Power draw

0.5 Amps

Operating environment

10 to 40°C (50 ― 104°F), maximum 95% RH

Storage environment

-20 to 70°C (-4 ― 158°F), maximum 95% RH

Size

315 x 205 x 375 mm

Mass

Nearly 4.3 kg with 1 pump, 1 stirrer and electrode

Supply includes

– HI932 titrator

         + HI932C1-02: 1 analog board

         + HI932C2-02: 2 analog boards

– Stirring paddle and electrode holder

– Burette 25mL

- Pump

- Temperature probe

- USB cable

– USB memory stick

– Adapter 

- Quality certification 

- User manual

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.