Force and mechanical measuring equipment
– Karl Fischer automatic volumetric titration
– High accuracy, flexibility and repeatability.
– Designed to perform titrations for a wide range of samples/sample matrices
– Wide scale from 1ppm to 5%.
– Automatically dispenses titrant, detects endpoint and performs all necessary calculations and graphs.
– Compact design will save space in the laboratory
– Supports up to 100 titration methods
– Plastic material has good chemical resistance.
– The sealed solvent system keeps water out of the system and minimizes contact with reagents.
+ HI934-02: without diaphragm
+ HI934D-02 : Have diaphragm
TITRATION PUMP
The titration rate feature enables timely and accurate titration results by relating the amount of iodine produced to the mV reaction from the Karl Fischer reaction.
COMPENSATION OF ERRORS BY DRIFT LINE
The HI934 automatically adjusts titration calculations to account for the effects of any environmental humidity entering the titration system, making measurements more accurate by compensating for water not present in the actual sample. international.
AVERAGE TITRATION RESULTS
Successive results from the titration method can be averaged with recording of the standard deviation.
CHEMICAL RESISTANT TANKERS AND TITRATION TUBE
Glass titration cells and PTFE tubes are designed to withstand the harsh solvents and reagents involved in Karl Fischer reactions.
CLOSED SOLVENT SYSTEM
The circular glass junctions completely seal the glass titration cell minimizing exposure to environmental humidity, keeping the system dry and reducing reagent consumption and saving time between titrations. Solvents can be exchanged in seconds with a quick fit adjustment.
MOLECULAR MOISTURE ABSORPTION NET
The highly efficient molecular desiccant mesh helps maintain a low and stable drift rate in the titration cell while preventing the penetration of environmental moisture into the closed solvent system.
DIGITAL STIRRING ARMS
The automatic magnetic stirrer integrated into the titration system is adjustable from 200-2000 rpm with optical feedback for automatic speed control.
SAVE REAGENT INFORMATION
The HI934 titration database can store information for up to 20 titrations. The database can be programmed to prompt the user when standardizing titrants, reducing errors in analysis.
REACTION END POINT OPTION
The HI934 uses a dual platinum pin electrode to determine the bivoltammetric endpoint. The user can select the end point based on mV stabilization time or drift current.
OPTIMAL PREPARATION PROCESS
Before titration, the machine automatically removes excess water from the solvent and sample, and calculates the diffuse flow of moist air into the system, providing reliable preparation for analysis. The maintenance mode will then keep the solvent dry between titrations and when the titrator is not in use.
EFFECTIVE SAMPLE HANDLING
The HI934 features a rapid sampling port with a replaceable rubber septum that allows for quick and easy sample introduction into the titration vessel. An integrated magnetic stirrer ensures uniformity for a precise and fast reaction.
CHEMICAL RESISTANCE TITTRATION TANK
Glass and PTFE titration cells and accessories are designed to withstand the harsh solvents and reagents associated with Karl Fischer titrations.
CLOSED SOLVENT SYSTEM
The titration vessel is completely sealed to minimize exposure to environmental humidity, keeping the system dry and reducing titrant consumption while saving time between titrations. Solvents can be exchanged in seconds without opening the titration vessel.
RECOGNIZED HUMIDIFICANT
Reusable, color-indicating silica gel desiccant beads help prevent the penetration of environmental moisture into sealed systems while maintaining full titration functionality. The change in color of the desiccant allows users to recognize when its desiccant capacity is full and needs to be replaced or regenerated.
DATA AND STORAGE SYSTEMS
RS232
Sample mass can be automatically entered from any laboratory analytical balance with RS232 serial output.
USB
Data can be easily transferred to a USB flash drive or PC with the Hanna HI900PC application software.
The USB port allows transfer of titration methods, titration reports and software upgrades via a USB flash drive.
Users can print reports directly from the titrator using a compatible printer.
ANALYTICAL METHODS
CUSTOM METHODS
The HI934 can store up to 100 user-defined or standard titration methods. Each method can be customized and optimized for performance based on application and user requirements.
SUPPORT TITRATION METHODS
On-site installation, training and customization are available from one of HANNA's Application or Services experts. HANNA will provide continuous support via phone or email throughout the process of using the machine.
ADAPTIVE STANDARD METHOD
HANNA's research department can program and customize standard methods developed by affiliates such as ISO, ASTM, AOAC, AOCS, EPA and more directly on titration equipment.
SPECIFICATIONS
The scale |
1 ppm to 5% |
Resolution |
0.1 ppm 0.0001% |
Unit |
%, ppm, ppt, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg Br/100g, g Br/100g, mg Br, g Br |
Sample type |
liquid or solid |
Conditions before titration |
automatic |
Identify the Drift line |
Automatic value or user preference |
End condition |
Fixed mV persistence, relative or absolute drift stop |
Pump mode |
Dynamic with pre-dispensing rate feature (pre-inject a certain amount of reagent into the sample to shorten titration time) |
Statistics of results |
average, standard deviation |
Generator electrode type |
with diaphragm or without diaphragm + HI934-02: without diaphragm + HI934D-02 : Have diaphragm |
Adjust generator current |
automatic or fixed (400 mA) |
Identify the generator electrode |
automatic |
Titration flask |
Operating volume from 100 – 200 mL |
Reagent handling system |
Closed system with integrated diaphragm air pump |
PUMP SPECIFICATIONS |
|
Resolution |
1/40000 burette volume (0.125 μL per injection) with 5 mL burette |
Accuracy |
±0.1% total burette volume |
Cylinder |
5 mL glass with PTFE plunger |
Pump valve |
3-way motor, PTFE liquid contact material |
Pipeline |
PTFE light-blocking and heat-insulating cover |
Dosing head |
glass, fixed position, anti-diffusion |
Titration flask |
conical shape with an operating volume of 50-150 mL |
Solvent treatment system |
Sealed system, integrated diaphragm air pump |
ELECTRODE |
|
Sensor |
HI76330 polarized electrode, double platinum |
Connector |
BNC |
Current polarity |
1, 2, 5, 10 μA |
Voltage scale |
2 mV to 1100 mV |
Voltage resolution |
0.1 mV |
Accuracy (@25ºC/77ºF) |
±0.1% |
STIRRING WINGS |
|
Stirring system |
Magnetic stirring, optical adjustment, digital stirring |
Speed |
200 to 2000 rpm |
Resolution |
100 rpm |
OTHER SPECIFICATIONS |
|
Screen |
5.7” color LCD (320 x 240 pixels) with backlight |
Method |
Up to 100 methods (standard and user-defined) |
Recorded data |
Up to 100 complete standard drift ratio reports can be stored |
Peripherals (Rear) |
Connect to VGA monitor, PC-keyboard, parallel printer, USB connection port, RS232 |
GLP |
Good laboratory practices and printing and archiving of machine data |
Language |
English, Portuguese. Spain and France |
Shell material |
ABS plastic and steel |
Keyboard |
Polyester |
Operating environment |
10 to 40°C (50 to 104°F), up to 95% RH |
Storage environment |
-20 to 70°C (-4 to 158°F), to 95% RH |
Electricity supply |
100-240 Vac, 50/60 Hz / 0.5 Amps |
Size |
315 x 205 x 375 mm |
Mass |
Nearly 4.3 kg with 1 pump, stirrer and electrode |
Guarantee |
12 months for body and 6 months for electrodes PRODUCT LIFETIME TECHNICAL AND METHODS SUPPORT |
Supply includes |
– Measuring machine HI934 (electrode without diaphragm) and HI934D (electrode with diaphragm) – 1 electrode dual platinum polarizer HI76330 – Pressure pump and pipes – Titration bottle set (glass bottle, lid, desiccant and tube, solution pipe) – 1 polarizing device - USB cable – USB – Adapter – CIndicates the quality of the factory - Warranty - User manual. |