Force and mechanical measuring equipment
– Quick measurement fluoride in clean water and fresh water
– Magnetic scale 0.0 to 20.0 ppm (mg/L) F–
– Higher accuracy and faster measurements than test kits
– Easy to use with just 1 button
– The device comes with 15 test reagents and necessary accessories for measurement.
– Sturdy, convenient plastic container.
FLORIDE IN CLEAN WATER
Fluoride is one of the very few chemicals that has been shown to have a significant effect on humans through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking water, but exposure to fluoride in drinking water alone, or in combination with exposure to fluoride from other sources, can cause a number of adverse effects. Water fluoridation is the addition of fluoride to public water supplies to reduce dental caries. Fluoride helps prevent tooth decay, too little may be ineffective, too much may cause tooth discoloration. The 1994 World Health Organization Expert Committee recommended fluoride levels of 0.5 to 1.0 mg/L, depending on climate. Bottled water and some home water filters typically remove some or all fluoride.
COMPACT SIZE WITH ONLY ONE BUTTON
Checker is compact in the palm of your hand, easy to put in your pocket when on the go.
EASY TO USE, QUICK MEASUREMENT
Fast measurement with only 10mL sample and included Reagents
LOW COST – HIGH ACCURACY
Cost savings but higher accuracy than test kits
EASY TO USE PRE-MEASURED
– Reagents are marked A, B for easy use step by step
– Just buy more reagents to continue measuring with the code: HI739-26
SUPPLIED COMPLETE SET
The HI739 is supplied complete with no additional purchase required.
– HI739 meter
– Reagents for 15 measurements
– 2 sample cuvettes with lids
– Convenient, sturdy plastic container
The scale |
0.0 to 20.0 ppm (mg/L) F– |
Resolution |
0.1 ppm |
Accuracy @25°C/77°F |
±0.5 ppm and ±5% measured values |
Calibration |
Checker ARE NOT has the function of calibrating/recalibrating the machine |
Light source |
silicon photovoltaic cell – LED @575nm |
Method |
Standard Methods for the Examination of Water and Wastewater, 18th Edition, SPADNS Method |
Environment |
0 to 50°C (32 to 122°F); RH max 95% does not condense |
The battery |
1 1.5V battery |
Automatically turns off |
after 10 minutes of non-use |
Size |
81.5mm x 61mm x 37.5mm |
Mass |
64 gr |
Guarantee |
06 months (For products with intact tags and warranty card) |
Supply includes |
– Measuring machine HI739 – 2 cuvette model with lid – Treagent for 15 measurements – Cylinder – Plastic pipette – Battery (in the device) - User manual - Warranty – Plastic container. |