Order code. 0633 3002 51
General specifications | |
---|---|
Operating humidity | 15 to 90 %RH no dew |
Weight | about 800g |
Size | 244 (including probe connection) x 98 x 59 mm (LxWxH) |
Operating temperature | -5 to +45 °C |
Protection level | IP40 |
Product color | black/orange |
Screen type | 5.0″ touch screen, HD 1280*720 pixels, IPS (160k) |
Power supply | Rechargeable battery, USB power source |
Certification | TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3 |
Guarantee | Gas sensors (O2, CO) 24 months; Thermocouple 12 months; Rechargeable battery: 12 months |
Warranty conditions | https://www.testo.com/guarantee |
Memory | 1,000,000 measurement values |
Battery type | lithium ion |
Battery life | 10 o'clock |
Storage temperatures | -20 to +50 °C |
Charging temperature | 0 to +45 °C |
Temperature – TC Type K (NiCr-Ni) | |
---|---|
Measuring range | -40 to +1200 °C |
Accuracy | ±0.5 °C (0.0 to +100.0 °C)
±0.5 % of measured value (Remaining measuring range) |
Resolution | 0.1 °C (-40 to +999.9 °C)
1 °C (Remaining range) |
Differential pressure – Piezoresistive | |
---|---|
Measuring range | -100 to +200 hPa |
Accuracy | ±0.5 hPa (0 to +50.0 hPa)
±1 % of measured value (+50.1 to +100.0 hPa) ±1.5 % of measured value (+100.1 to +200 hPa) |
Resolution | 0.01 hPa |
Flue gas O2 | |
---|---|
Measuring range | 0 to 21 Vol.% |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Flue gas CO (with H2 compensation) | |
---|---|
Measuring range | 0 to 8000 ppm |
Accuracy | ±10 ppm or ±10 % measurement value (0 to 200 ppm)
±20 ppm or ±5 % measured value (201 to 2000 ppm) ±10 % measured value (2001 to 8000 ppm) |
Resolution | 1 ppm |
Differential Pressure flue gas Draft – Piezoresistive | |
---|---|
Measuring range | -9.99 to +40 hPa |
Accuracy | ±0.005 hPa (0 to 0.1 hPa)
±0.02 hPa (0.1 to +3.00 hPa) ±1.5 % of measured value (+3.01 to +40 hPa) |
Resolution | 0.001 hPa (0 to 0.1 hPa)
0.01 hPa (Remaining range) |
Combustion efficiency, Eta (calculated) | |
---|---|
Measuring range | 0 to 120 % |
Resolution | 0,1 % |
Furnace efficiency (calculated) | |
---|---|
Measuring range | 0 to 99.9% |
Resolution | 0,1 % |
CO2 in exhaust gas (calculated from O₂) | |
---|---|
Measuring range | Display from 0 to CO2 max |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
CO surrounding | |
---|---|
Measuring range | 0 to 2000 ppm |
Accuracy | ±10 ppm (0 to 100 ppm)
±10 % measured value (101 to 2000 ppm) |
Resolution | 1 ppm |
Order code. 0600 9740
General specifications | |
---|---|
Sampling head shaft diameter | 6mm |
Cable length | 1.5 m |
Sampling head shaft length | 180mm |
Product color | Black |
Maximum temperature | 500°C |
Diameter | 6mm |
Weight | 346 grams |
Order code. 0554 3332
General specifications | |
---|---|
System requirements | Windows® 7; Windows® 8; Windows® 10 |
Order code. 0554 1106
General specifications | |
---|---|
Weight | 144 grams |
Size | 85 x 55 x 90 mm (LxWxH) |
Product color | Black |
Cable length | 2 m |
Power supply | 230 V AC / 5 V DC (2 A), micro USB |
Order code. 0554 3004
General specifications | |
---|---|
Battery life | None, operated via testo 300 |
Connect | TUC 1 or TUC 2 |
Radio connection range | 100 m |
Compatible with | testo 510i, testo 115i, testo 915i |