General specifications | |
---|---|
Weight | 573 g |
Size | 240x85x65mm |
Operating temperature | -5 to +45 °C |
Screen resolution | 240 x 320 pixels |
Display screen | color screen |
Power supply | Battery: 3.7 V / 2,400 mAh; Power supply: 6 V / 1.2 A |
Maximum memory | 500 measurement values |
Storage temperatures | -20 to +50 °C |
CO emissions (with H2 compensation) | |
---|---|
Measuring range | 0 to 8000 ppm |
Accuracy | ±10 ppm or ±10 % measurement value (0 to 200 ppm)
±20 ppm or ±5 % measured value (201 to 2000 ppm) ±10 % measured value (2001 to 8000 ppm) |
Resolution | 1 ppm |
Response time t₉₀ | < 40 seconds |
COlow emissions (with H2 compensation) | |
---|---|
Measuring range | 0 to 500 ppm |
Accuracy | ±2 ppm (0 to 39.9 ppm)
±5 % measured value (40 to 500 ppm) |
Resolution | 0.1 ppm |
Response time t₉₀ | < 40 seconds |
Differential exhaust pressure draft – Piezoresistive | |
---|---|
Measuring range | -9.99 to +40 hPa |
Accuracy | ±0.02 hPa or ±5 % of measured value (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa) ±1.5 % measured value (+3.01 to +40.00 hPa) |
Resolution | 0.01 hPa with fine draft option 0.001 hPa |
Temperature | |
---|---|
Measuring range | -40 to +1200 °C |
Accuracy | ±0.5 °C (0 to +100.0 °C)
±0.5 % measured value (remaining measuring range) |
Resolution | 0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C) |
Combustion efficiency, Eta | |
---|---|
Strip due | 0 to 120 % |
Resolution | 0,1 % |
Loss of exhaust gas | |
---|---|
Measuring range | 0 to 99.9% |
Resolution | 0,1 % |
CO2 (calculated from O2) | |
---|---|
Measuring range | Display range from 0 to CO2max |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Pressure | |
---|---|
Measuring range | 0 to +300 hPa |
Accuracy | ±0.5 hPa (0.0 to 50.0 hPa)
±1 % measured value (50.1 to 100.0 hPa) ±1.5 % measured value (Remaining measuring range) |
Resolution | 0.1 hPa with fine draft option 0.01 hPa |
CO emissions (without H2 compensation) | |
---|---|
Measuring range | 0 to 4000 ppm |
Accuracy | ±20 ppm (0 to 400 ppm)
±5 % measured value (401 to 2000 ppm) ±10 % measured value (2001 to 4000 ppm) |
Resolution | 1 ppm |
CO surrounding | |
---|---|
Measuring range | 0 to 500 ppm |
Accuracy | ±5 ppm (0 to 100 ppm)
±5 % measured value (> 100 ppm) |
Resolution | 1 ppm |
with CO probe (order code. 0632 3331)
Ambient CO2 | |
---|---|
Measuring range | 0 to 1 Vol.%
0 to 10000 ppm |
Accuracy | ±75 ppm or ±3 % measured value (0 to 5000 ppm)
±150 ppm or ±5 % measured value (5001 to 10000 ppm) |
with ambient CO2 probe (order code. 0632 1240)
Gas leak measurement for flammable and explosive gases (via gas leak detector) | |
---|---|
Measuring range | 0 to 10000 ppm CH4/C3H8 |
Accuracy | Signal optical display (LED) audible signal via buzzer |
Response time t₉₀ | < 2 seconds |
Has gas leak detector (order code. 0632 3330)