Force and mechanical measuring equipment
– Handheld thermometer type K, 1 channel
– Wide measuring range from -50.0 to 1350°C
– Accuracy ± 0.2%
– Display high and low temperature
– Only 1 temperature electrode can be attached
– Compatible with all types electrode K type temperature (purchased separately)
HIGH/LOW TEMPERATURE DISPLAY
The maximum and minimum temperature values are continuously monitored and displayed below the LCD display during measurement. The CLR button clears the high and low values on the LCD display.
HOLD BUTTON
Hold values on display. While the display is held, the meter continues to monitor the temperature and update the high and low readings.
USE A PROBE WITH A K CONNECTION PORT
A variety of K-type probes are available to meet specific user needs.
The HI766 probe series can be interchanged with the HI93542 to measure the temperature of surfaces, gases, air, liquids, semi-solid samples, and more.
The HI935005 is a K-type thermocouple thermometer that can be used with a variety of K-type probes. It offers two ranges from -50.0 to 199.9°C and 200 to 1350°C or can be displayed in °F (-58.0 to 399.9°F and 400 to 2462°F). With a full-scale accuracy of ±0.2%, the waterproof HI935005 is well suited for laboratory and field temperature measurements.
SALIENT FEATURES
°C/°F – Measurements can be displayed in either Celsius or Fahrenheit. Simply pressing the °C/°F button will switch between units.
Interchangeable probe – A variety of K-type probes are available to meet the specific needs of the user. The HI766 probe series can be interchanged with the HI935005 to measure the temperature of surfaces, gases, air, liquids, semi-solid samples, and more.
High/Low Function – Maximum and minimum temperature values are continuously monitored and displayed below the LCD display during measurement. CLR button to clear high and low values on the LCD display.
Hold Function – The HOLD button on the meter allows the values on the display to be held. Although the display is held, the meter continues to monitor the temperature and update the high and low readings.
Automatically turns off – The machine automatically turns off after 8 or 60 minutes of non-use or non-activation.
Battery Error Prevention System (BEPS) – Detects when battery is too low to ensure reliable measurements.
Low battery indicator – When the battery level is below 10%, a warning icon will flash to indicate low battery condition.
SPECIFICATIONS
Scale (°C) |
50.0 to 199.9°C and 200 to 1350°C |
Scale (°F) |
; -58.0 to 399.9°F and 400 to 2462°F |
Resolution (°C) |
0.1°C (-50.0 to 199.9°C) and 1°C (off scale) |
Resolution (°F) |
0.1°F (-58.0 to 399.9°F) and 1°F (off scale) |
Accuracy |
±0.2% full scale (excluding probe error) |
Electrode / Probe |
HI766 Type K (purchased separately): https://hannavietnam.com/detailcate/136-136 |
The battery |
1.5V AA (3) / approximately 1600 hours of continuous use |
Automatically turns off |
8 minutes (default), 60 minutes or OFF |
Environment |
-10 to 50°C (14 to 122°F); RH max 100% |
Size |
150 x 80 x 36 mm |
Mass |
235 g |
Supply includes |
HI935005 is supplied with batteries, protective case, instructions. K-type temperature probe purchased separately |
Guarantee |
12 months for machine |