Force and mechanical measuring equipment
– The most advanced benchtop dissolved oxygen/temperature meter
– Touch keypad and large color LCD screen
– Record data automatically
– USB connection
– CAL Check™ alerts when the electrode needs cleaning or recalibration
– Provides a complete set of meters, electrodes and necessary accessories without the need to purchase anything else.
+ HI5421-01: 115V
+ HI5421-02: 230V
MODERN, EASY TO USE INTERFACE
There are two basic and advanced interfaces: with or without GLP information, real-time, and data logging.
COLOR LCD GRAPHIC DISPLAY
Graphic display, and customizable color configuration. The display allows real-time and virtual keys to provide intuitive user support.
TOUCH KEYBOARD
Capacitive touch keypad for precise navigation of menus and screens. There are 4 dedicated keys used frequently including calibration and switching measurement modes and 4 virtual keys that change when used. Capacitive touch technology ensures the buttons never get stuck.
USB PORT
Data can be transferred to a computer with the USB cable and HI92000 software.
DATA LOG
– 3 logging modes are available on the HI5221: automatic, manual, and AutoHold.
– Manual and automatic recording of up to 100 batches with up to 50,000 records/batch, for a total of up to 100,000 data points.
– Automatic recording feature to save data by time and sampling interval.
CAL Check™
Hanna Instruments exclusive CAL Check™ feature alerts the user to problems during calibration such as contaminated buffers or probes that need to be cleaned or replaced.
AUTOMATIC CALIBRATION
– Calibration has automatic, semi-automatic, direct buffer recognition and direct manual entry options
– Automatic calibration is available for 2 points at 0% and 100% saturation or 0 mg/L and 8.26 mg/L. One standard User options are available for a user-defined value.
SPECIFICATIONS
Dissolved oxygen scale |
0.00 arrive 90.00 ppm (mg/L) 0.0 arrive 600.0% saturation -20.0 to 120.0ºC |
Resolution dissolved oxygen |
0.01 ppm (mg/L) 0.1% saturation 0.1ºC |
Accuracy dissolved oxygen |
±1.5% measurement result and ±1 digit ± 0.2°C |
Calibration dissolved oxygen |
– Automatic at 1 or 2 points 0% and 100% saturation or 0 mg/L and 8.26 mg/L –Automatic at 1 user point |
Dissolved oxygen electrode |
HI76483 slim body, polarographic, built-in temperature sensor, 1 m cable |
Temperature compensation |
Automatic or manual from 0 to 50 degrees C |
Salinity compensation |
0 to 45ppt |
Atmospheric pressure scale |
450 arrive 850 mmHg 600 up to 1133 mBar 60 to 133 KPa 17 to 33 inHg 8.7 to 16.4 psi 0.592 to 1.118 atm |
Resolution atmospheric pressure |
1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm |
Accuracy atmospheric pressure |
±3 mm Hg + at least 1 digit |
Calibration atmospheric pressure |
1 point |
Record data |
Up to 100 lots with up to 50,000 copies/lot; up to 100,000 data points 5000 samples/lot when Manual Recording Interval recording: 14 options from 1 second to 180 minutes. Recording type: Manual, AutoHOLD, Automatic. |
PC connection port |
USB |
Alarm (DO, BOD, SOUR, OUR) |
inner and outer limits |
Electricity supply |
12V Adapter |
Size |
160 x 231 x 94 mm |
Mass |
1.2 Kg |
Guarantee |
12 months for the machine and 06 months for the included electrodes (for products with intact tags and warranty card) |
Supply includes |
– HI5421 meter. – Dissolved Oxygen Electrode HI76483 Slim body, polarographic, built-in temperature sensor, 1m long cable. – HI7041S Membrane Cap Filling Solution, 30mL – 2 membrane caps and 2 O-rings – Electrode holder. – Adapter. + HI5421-01: 115V + HI5421-02: 230V – Warranty. – Quality certificate for machine and electrodes – User manual. – Paper container. |