pH/ORP/Conductivity/TDS/Salinity/DO/Pressure/Temperature Meter with Bluetooth HI98494

Producer:
SKU: HANNA-HI98494 Category:

– Measures 12 different water quality parameters

– 1 multiparameter probe contains all pH, EC and DO optical sensors.

– Quick calibration

– USB.

– Record data automatically

– Data extraction using Bluetooth and Hanna Lab App (Itunes, Appstore)

– Optional electrode cable length:

     + HI98494: 4m cable 

     + HI98494/10: 10m cable

     + HI98494/20: 20m cable

     + HI98494/40: 40m cable 

±Durable body

Designed to withstand real-life bumps, drops and spills, the IP67 body ensures top performance in any environment, protected against dust and water ingress from any direction.

Measurement & Data Recording

Measure up to 12 parameters. Never lose important data with automatic interval logging of up to 45,000 samples or choose on-demand logging to store measurement data for key points.

Dual power supply

The machine operates on a built-in lithium-ion battery and will automatically switch to AA alkaline batteries for at least 200 hours of use.

 

 

 

 

GLP Data
For better traceability, calibration information is recorded along with time and date stamps and stored with the logged data.
Quick Calibration (Quick CAL)
Quick 1-point neutral calibration for pH, conductivity and dissolved oxygen is required. Alternatively, individual or point-by-point calibration options are also available.

 

 

 

 

 

Quick DIN probe connection

Attaching and removing the probe is simple and easy. The rubber coating protects the cable and provides waterproof protection and prevents the cable from twisting.

Digital probe

Digital probe with built-in temperature sensor and three ports for pH (ORP), EC and optical DO sensors. Once connected, the meter automatically recognizes the sensors.

 

 

Data transfer and battery charging

The USB Type-C port provides easy data transfer to a memory card, PC or other device and is used to charge the internal lithium-ion battery.

GLP Data

For better traceability, calibration information is recorded along with time and date stamps and stored with the logged data.

 

 

 

Multi-parameter probes and sensors

Sensor replacement is quick and easy with screw-type, field-replaceable connectors that are color-coded for easy identification.

– pH sensor HI7698194-0 or pH/ORP sensor HI7698194-1

– EC sensor HI7698194-3

– HI7698494-5 DO Photoelectric Sensor: uses a smart membrane cap with an RFID tag that tracks the age of the cap and notifies you when it needs to be replaced. (membrane cap life is 1 year from activation)

 

 

 

 


Bluetooth® wireless connection to smart device when connecting Hanna Lab App

Measure & Graph

Select the units of measurement that will be displayed on your smart device. To analyze trends, view a graph of your recorded data.

Good Laboratory Practice (GLP)

Comprehensive GLP data can be reviewed for all parameters when the recorded data is downloaded to your smart device.

Organize & Share Data

Group your data by time or symbol. Email it to archive or share it with friends or colleagues.

 

 

 

 

 

SPECIFICATIONS

pH/mV

The scale

0.00 – 14.00 pH/ ±600.0 mV

Resolution

0.01 pH/ 0.1 mV

Accuracy

±0.02 pH/ ±0.5 mV

Calibration

Automatic, 1 point using Quick Calibration solution HI9828-25

Automatic, 3 points in standard buffer system (pH 4.01; 6.86; 7.01; 9.18; 10.01) or 1 point set by user

ORP

The scale

±2000.0 mV

Resolution

0.1 mV

Accuracy

±1.0 mV

Calibration

1 user-defined point (relative mV)

EC

(conductivity)

The scale

0 – 200 mS/cm (maximum 400 mS/cm)

Resolution

Automatic or manual

Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm

Automatic: 1 µS/cm range from 0 to 9999 µS/cm

                           0.01 mS/cm measuring range from 10.00 to 99.99 mS/cm

                           0.1 mS/cm measuring range from 100.0 to 400.0 mS/cm

Automatic (mS/cm): 0.001 mS/cm measuring range from 0.000 to 9.999 mS/cm

                            0.01 mS/cm measuring range from 10.00 to 99.99 mS/cm

                            0.1 mS/cm measuring range from 100.0 to 400.0 mS/cm

Accuracy

±1% measured value or ±1 µS/cm (whichever is larger)

Calibration

Automatic, 1 point using Quick Calibration solution HI9828-25

Automatic, 1 point in buffer system (84 µS/cm; 1413 µS/cm; 5.00 mS/cm; 12.88 mS/cm; 80.0 mS/cm; 111.8 mS/cm) or user defined

Impedance

The scale

0 to 999999 Ω•cm

Resolution

1 Ω•cm; 0.1k Ω•cm; 0.0001 MΩ•cm

Calibration

By conductivity or salinity standard

TDS

(Total dissolved solids)

The scale

0.0 – 400000 ppm (mg/L) (depending on TDS factor)

Resolution

Automatic or manual

Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L);

                           1 ppt (g/L)

Automatic: 1 ppm (mg/L) scale from 0 to 9999 ppm (mg/L)

                           0.01 ppt (g/L) scale from 10.00 to 99.99 ppt (g/L)

                           0.1 ppt (g/L) scale from 100.0 to 400.0 ppt (g/L)

Auto ppt (g/L) : 0.001 ppt (g/L) measuring range from 0.000 to 9.999 ppt (g/L)

                            0.01 ppt (g/L) scale from 10.00 to 99.99 ppt (g/L)

                            0.1 ppt (g/L) scale from 100.0 to 400.0 ppt (g/L)

Accuracy

±1% measured value or ±1 ppm (mg/L) (whichever is larger)

Calibration

Based on conductivity calibration

Air pressure

The scale

450.0 – 850.0 mmHg; 17.72 – 33.46 inHg; 600.0 – 1133.2 mbar; 8,702 – 16,436 psi; 0.5921 – 1.1184 atm; 60.00 – 113.32 kPa

Resolution

0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

Accuracy

±3.0 mmHg within ±15 0 C from temperature calibration point

Calibration

At a user-defined point

Dissolved oxygen (DO)

The scale

0.00 to 50.00 mg/L (ppm)

0.0 to 500.0 % saturated

Resolution

0.01 mg/L (ppm)

0.1 % saturated

Accuracy

Measuring range from 0.00 to 20.00 mg/L: ±1.5 % measuring result ±0.01 mg/L 

Measuring range from 20.00 to 50.00 mg/L: ±5% measurement result

Measuring range from 0.0 to 200.0% saturation: ±1.5 % measurement result

Measuring range from 200.0 to 500.0 % saturation: ±5 % measurement result

Calibration

At 1 point, fast calibration in air saturated water

At 1 or 2 points, at 100% and 0%

At 1 point, use the calibration solution of your choice (in % saturated or mg/L)

Salinity

The scale

0.00 to 70.00 PSU

Resolution

0.01 PSUs

Accuracy

±2% measurement result or ±0.01 PSU, whichever is greater

Calibration

1 point, use solution of choice

σ Sea water

The scale

0.0 to 50.0 σt, σ₀, σ₁₅

Resolution

0.1 σt, σ₀, σ₁₅

Accuracy

±1 σt, σ₀, σ₁₅

Calibration

By conductivity or salinity standard

Temperature

The scale

-5.00 to 50.00  0C

23.00 to 122.00 0F

268.15 to 323.15 K

Resolution

0.01 0C; 0.010F; 0.01K

Accuracy

±0.15 0C; ±0.27 0F; ±0.15 K

Calibration

At a user-defined point

Heat compensation

Automatic, in the range of -5 – 50 0C

Memory to save measurement results

Automatic storage, 50,000 measurement results

Save on demand, 20,000 measurement results

Automatic measurement result storage interval

User selectable

1 second – 3 hours

Connect

Bluetooth via Hanna Lab app

USB-C: save data to memory card

Computer connection: displayed with .MSD extension on computer

Operating environment

0 – 500C; RH 100% IP67

The battery

4 1.5V AA batteries and Li-ion battery built in

Size

185 x 93 x 35.2 mm

Guarantee

12 months for machine and 06 months for electrodes

(For products with intact tags and warranty card)

Supply includes

– HI98494 meter

– Multi-parameter probe HI7698494

     + HI98494 comes with 4m cable electrode HI7698494/4.

     + HI98494/10 supplied with 10m cable electrode HI7698494/10.

     + HI98494/20 is supplied with 20m HI7698494/20 electrode cable.

     + HI98494/40 is supplied with 40m HI7698494/40 electrode cable.

– pH/ORP sensor HI7698194-1

– EC sensor HI7698194-3

– DO sensor HI7698494-5

– Probe protection tube

– HI9828-0 (HI9828-25) Quick Calibration Solution

– DO calibration solution at 0%

– Electrode maintenance kit HI76984942

– USB-C cable

– 4 1.5V AA batteries and Li-ion battery are built into the machine

- User manual

– Quality certification for machines, probes and sensors

- Warranty.

– Carrying case.

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.