Force and mechanical measuring equipment
– Measure up to 12 different water quality parameters.
– Measure important parameters such as pH, ORP, conductivity, dissolved oxygen and temperature
– Only 1 probe with 4 multi-parameter sensors
– Convenient 1-point quick calibration for pH, EC, TDS
– Very simple to install and easy to use.
– The HI98194 is supplied with meter, probe, and all necessary accessories in a sturdy carrying case.
– Multiple length options for electrode cables:
+ HI98194: cable electrode 4m
+ HI98194/10: electrode cable 10m
+ HI98194/20: electrode cable 20m
+ HI98194/40: electrode cable 40m
LCD DISPLAY AND BACKLIGHT
The HI98194 features a graphical LCD with on screen help and the ability to display up to twelve parameters at once. The graphical display allows for the use of virtual keys to provide the user with an intuitive interface.
AUTOMATIC DATA RECORDING
The HI98194 allows users to record up to 45,000 continuous or on-demand records with logging intervals ranging from 1 second to 3 hours.
GLP DATA
The HI98194 offers GLP functionality that allows users to view calibration data and calibration expiration information with the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.
USB CONNECTION.
Saved data can be transferred to a PC using the HI9298194 Window compatible software and HI920015 USB cable.
Quick DIN connection.
Waterproof, easy to connect and kink free.
SENSORS ARE REPLACEABLE AND HAVE THEIR OWN COLOR
The sensors can be replaced quickly and easily, each sensor has its own color for easy identification of the corresponding colored connection port.
AUTOMATIC SENSOR RECOGNITION
The probe and machine automatically recognize the sensors when connected.
Any unused port at the probe will have no parameters displayed or configured..
MULTIPLE CABLE LENGTH OPTIONS
The probe has a variety of cable length options with 4m, 10m, 20m, 40m.
QUICK CAL
Fast single point calibration for pH, conductivity
CALIBRATION POINT BY POINT FOR EACH INDICATOR
– pH calibration using built-in standards up to 3 points with 1 of 5 standard buffers and 1 custom buffer.
– Single point conductivity calibration from six built-in standards or one custom standard.
– Calibrate dissolved oxygen at 100% in air or 0 mg/L with HI7040 standard solution.
PROVIDE FULL NECESSARY ACCESSORIES IN ONE STURDY SUITCASE
– The interior compartments of the suitcase are firmly framed to hold and protect all accessories safely.
– Provides a complete set of accessories in a sturdy, compact suitcase, extremely convenient without having to buy anything else:
+ HI98194 meter
+ Probe with pH, EC, oxygen sensors.
+ Standard solution, oxygen measuring membrane cap, USB cable, protective tube, case, battery.
USER MANUAL
HOW TO REPLACE THE MEMBRANE FOR THE DO SENSOR
SPECIFICATIONS
pH scale |
0.00 to 14.00 pH |
pH resolution |
0.01 pH |
pH accuracy |
±0.02 pH |
pH calibration |
Automatic 1, 2 or 3 points (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer |
mV – pH scale |
±600.0 mV |
mV – pH resolution |
0.1 mV |
mV – pH accuracy |
±0.5 mV |
ORP scale |
±2000.0 mV |
ORP resolution |
0.1 mV |
ORP Accuracy |
±1.0 mV |
ORP calibration |
automatic at 1 custom point (relative mV) |
Conductivity Scale |
0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC to 400.0 mS/cm) |
Resolution Conductivity |
Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; by hand: 1 µS/cm; 0.001 mS/cm; 0.01 |
Accuracy Conductivity |
±1 % measured result or ±1µS/cm whichever is greater |
Calibration Conductivity |
Automatic 1 point (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom |
TDS scale |
0 to 9999 ppm (mg/L) 0.000 to 400.0 ppt (g/L) (maximum value based on TDS factor) |
TDS resolution |
By hand: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L) Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L) ;0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L) |
TDS accuracy |
±1% measurement result or ±1 ppm whichever is greater |
TDS calibration |
According to conductivity calibration |
Impedance Scale |
0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Impedance Resolution |
Based on impedance measurement results |
Impedance Calibration |
According to conductivity calibration |
The scale Salinity |
0.00 to 70.00 PSU |
Salinity Resolution |
0.01 PSUs |
Salinity Accuracy |
±2% measured value or ±0.01 PSU whichever is greater |
Salinity Calibration |
According to conductivity standard |
σ Scale Seawater |
0.0 to 50.0 σt, σ₀, σ₁₅ |
Resolution σ Seawater |
0.1 σt, σ₀, σ₁₅ |
Accuracy σ Seawater |
±1 σt, σ₀, σ₁₅ |
Calibration σ Seawater |
According to conductivity standard |
Dissolved oxygen scale |
0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
Resolution dissolved oxygen |
0.1%; 0.01 ppm (mg/L) |
Accuracy dissolved oxygen |
0.0 to 300.0 %: ± 1.5 % result or ± 1.0 % larger value 300.0 to 500.0 %: ± 3 % measurement result 0.00 to 30.00 ppm (mg/L): ± 1.5 % of measurement result or ±0.10 ppm (mg/L) whichever is greater 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ± 3 % measurement result |
DO calibration |
automatic 1 or 2 points at 0mg/L and 100% or custom points |
Pressure Scale |
450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8,702 to 16,436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Pressure Resolution |
0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Pressure Accuracy |
±3 mm Hg within ±15°C from standard temperature |
Pressure Calibration |
automatically at a selected point |
Temperature scale |
-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
Temperature Resolution |
0.01 K, 0.01 °C, 0.01 °F |
Temperature accuracy |
±0.15 °C; ±0.27 °F; ±0.15 K |
Temperature Calibration |
automatically at a selected point |
Temperature Compensation |
automatic from -5 to 55 °C (23 to 131 °F) |
Memory storage |
45,000 copies (continuous or on-demand recording) |
Record by time period |
From 1 second to 3 hours |
PC connection |
USB port with HI9298194 software |
The battery |
4 x 1.5 V/ approx. 360 hours continuous use without backlight (50 hours with backlight) |
Environment |
0 to 50°C (32 to 122°F); RH 100% (IP67) |
Size |
185 x 93 x 35.2 mm |
Mass |
400 g |
Guarantee |
12 months for machine; 06 months for electrodes and sensors included (for products with intact tags and warranty card) |
Supply includes |
– Measuring machine HI98194 – Multi-parameter probe HI7698194 + HI98194: electrode cable 4m + HI98194/10: electrode 10m cable + HI98194/20: electrode 20m cable + HI98194/40: electrode 40m cable – pH/ORP sensor HI7698194-1 – EC/TDS/NaCl Sensor HI7698194-3 – Dissolved oxygen sensor HI7698194-2 – HI9828-0 Quick Standard Solution for pH and Conductivity (230mL) – Accessory kit for dissolved oxygen sensor HI76981942 (1 bottle of dissolved oxygen)DO membrane electrolysis solution HI7042S (30mL) and membrane cap (5 pcs) and O-rings (5 pcs), 1 cylinder with 1 pack of grease to lubricate the O-rings) - USB cable. – 4 AA 1.5V batteries. - User manual. – Quality certification for machines, probes and sensors. - Warranty. – Carrying case. |