Force and mechanical measuring equipment
– Measure important parameters such as pH, ORP, EC, TDS, salinity, impedance and temperature.
– With only 1 multi-parameter probe.
– Quick 1 point calibration for all parameters.
– Very simple to install and easy to use.
– Measuring machine HI98195 is supplied with probe and all necessary accessories in a sturdy carrying case.
– Multiple length options for electrode cables:
+ HI98195: cable electrode 4m
+ HI98195/10: electrode cable 10m
+ HI98195/20: electrode cable 20m
+ HI98195/40: electrode cable 40m
LCD DISPLAY AND BACKLIGHT
The HI98195 features a graphical LCD with on screen help and the ability to display all parameters at once. The graphical display allows for the use of virtual keys to provide the user with an intuitive interface.
AUTOMATIC DATA RECORDING
The HI98195 allows users to record up to 45,000 continuous or on-demand records with logging intervals ranging from 1 second to 3 hours.
GLP DATA
The HI98195 offers GLP functionality that allows users to view calibration data and calibration expiration information with the press of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.
USB CONNECTION.
Saved data can be transferred to a PC using the HI9298194 Window compatible software and HI920015 USB cable.
Quick DIN connection.
Waterproof, easy to connect and kink free.
SENSORS ARE REPLACEABLE AND HAVE THEIR OWN COLOR
The sensors can be replaced quickly and easily, each sensor has its own color for easy identification of the corresponding colored connection port.
AUTOMATIC SENSOR RECOGNITION
The probe and machine automatically recognize the sensors when connected.
Any unused port at the probe will have no parameters displayed or configured..
MULTIPLE CABLE LENGTH OPTIONS
The probe has a variety of cable length options with 4m, 10m, 20m, 40m.
QUICK CAL
Fast single point calibration for pH, conductivity, and dissolved oxygen.
CALIBRATION POINT BY POINT FOR EACH INDICATOR
– pH calibration using built-in standards up to 3 points with 1 of 5 standard buffers and 1 custom buffer.
– Single point conductivity calibration from six built-in standards or one custom standard.
Only need to standardize 1 conductivity index for EC/TDS and salinity
PROVIDE FULL NECESSARY ACCESSORIES IN ONE STURDY SUITCASE
– The interior compartments of the suitcase are firmly framed to hold and protect all accessories safely.
– Provides a complete set of accessories in a sturdy, compact suitcase, extremely convenient without having to buy anything else:
+ HI98195 meter
+ Probe with pH, EC sensors.
+ Standard solution, oxygen measuring membrane cap, USB cable, protective tube, case, battery.
SPECIFICATIONS
pH scale |
0.00 to 14.00 pH |
pH resolution |
0.01 pH |
pH accuracy |
±0.02 pH |
pH calibration |
Automatic 1, 2 or 3 points (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer |
mV – pH scale |
±600.0 mV |
mV – pH resolution |
0.1 mV |
mV – pH accuracy |
±0.5 mV |
ORP scale |
±2000.0 mV |
ORP resolution |
0.1 mV |
ORP Accuracy |
±1.0 mV |
ORP calibration |
automatic at 1 custom point (relative mV) |
Conductivity Scale |
0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC to 400.0 mS/cm) |
Conductivity Resolution |
Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; by hand: 1 µS/cm; 0.001 mS/cm; 0.01 |
Conductivity Accuracy |
±1 % measured result or ±1µS/cm whichever is greater |
Conductivity Calibration |
Automatic 1 point (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom |
TDS scale |
0 to 9999 ppm (mg/L) 0.000 to 400.0 ppt (g/L) (maximum value based on TDS factor) |
TDS resolution |
By hand: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L) Auto ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L) ;0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L) |
TDS accuracy |
±1% measurement result or ±1 ppm whichever is greater |
TDS calibration |
According to conductivity calibration |
Impedance Scale |
0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Impedance Resolution |
Based on impedance measurement results |
Impedance Calibration |
According to conductivity calibration |
Salinity Scale |
0.00 to 70.00 PSU |
Salinity Resolution |
0.01 PSUs |
Salinity Accuracy |
±2% measured value or ±0.01 PSU whichever is greater |
Salinity Calibration |
According to conductivity standard |
σ Scale Seawater |
0.0 to 50.0 σt, σ₀, σ₁₅ |
Resolution σ Seawater |
0.1 σt, σ₀, σ₁₅ |
Accuracy σ Seawater |
±1 σt, σ₀, σ₁₅ |
Calibration σ Seawater |
According to conductivity standard |
Pressure Scale |
450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8,702 to 16,436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Pressure Resolution |
0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Pressure Accuracy |
±3 mm Hg within ±15°C from standard temperature |
Pressure Calibration |
automatically at a selected point |
Temperature scale |
-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
Temperature Resolution |
0.01 K, 0.01 °C, 0.01 °F |
Temperature accuracy |
±0.15 °C; ±0.27 °F; ±0.15 K |
Temperature Calibration |
automatically at a selected point |
Temperature Compensation |
automatic from -5 to 55 °C (23 to 131 °F) |
Memory storage |
45,000 copies (continuous or on-demand recording) |
Record by time period |
From 1 second to 3 hours |
PC connection |
USB port with HI9298194 software |
The battery |
4 x 1.5 V/ approx. 360 hours continuous use without backlight (50 hours with backlight) |
Environment |
0 to 50°C (32 to 122°F); RH 100% (IP67) |
Size |
185 x 93 x 35.2 mm |
Mass |
400 g |
Guarantee |
12 months for machine; 06 months for electrodes and sensors included (for products with intact tags and warranty card) |
Supply includes |
– HI98195 Meter – Probe HI7698194 – pH/ORP sensor HI7698194-1 – EC/TDS/NaCl Sensor HI7698194-3 - USB cable. – 4 AA 1.5V batteries. - User manual. – Quality certification for machines, probes and sensors. - Warranty. – Carrying case. |