Force and mechanical measuring equipment
– 2 independent measurement channels:
+ CHANNEL 1: pH/mV/ISE and temperature
+ CHANNEL 2: EC/TDS, NaCL/Impedance and temperature
– Save data
– Notification screen when the electrode needs cleaning
– GLP data related to pH calibration, Rel mV, ISE, EC, salinity
– Supplied with meter, power adapter, quality certificate
+ HI3512-01: 115V
+ HI3512-02: 230V
HI3512 DOES NOT COMES WITH ELECTRODE
HI3512 is a professional benchtop pH meter with LCD display:
• pH/mV/ISE and temperature measurement (Channel 1)
• Measure EC/TDS, NaCl/Impedance and Temperature (Channel 2)
The HI3512 is provided with several new features to improve measurement reliability.
pH channel
– 7 standard pH buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)
– pH calibration up to 5 points
– Custom calibration with up to two buffers
– On-screen notifications make calibration simple and accurate
– Has a notification function when the electrode needs to be washed
EC Channel
– 7 standard memories (0.00 µS/cm, 84.0 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm)
– EC calibration up to 2 points
– LCD display notifications for easy and accurate calibration
– Has a notification function when the electrode needs to be washed.
– Set lock and select fixed scale
Other functions
– Save data up to 400 samples
– Save login data with stable feature up to 600 records.
– Auto Hold function, keeps the first measurement result on the screen.
– GLP function, to look up pH, Rel mV or ISE calibration data.
– PC connection.
This device can also measure with an ORP electrode (pH channel) thanks to its ability to measure mV with resolution up to 0.1 mV and with ISE electrodes on the ppm scale (pH channel).
Electrode type with selectable unit and up to five point ISE calibration makes this device Useful for many concentration solution measurements. Relative mV feature is also available.
This device can also measure resistivity, TDS and salinity in the EC channel.
ISE ELECTRODE AND NECESSARY SOLUTIONS AND ACCESSORIES
https://hannavietnam.com/blog-detail/dien-cuc-ise-va-cac-dung-dich-phu-kien-can-thiet-122
SPECIFICATIONS
pH |
The scale |
-2.0 to 20.0 pH -2.00 to 20.00 pH -2,000 to 20,000 pH |
Resolution |
0.1, 0.01, 0.001 pH |
|
Accuracy |
±0.01 pH, ±0.002 pH |
|
Calibration |
Up to 5 points with 7 cushions 1.68, 4.01, 6.86, 7.01, 9.18, 10.01,12.45 2 custom cushions |
|
Heat compensation |
Automatic or manual |
|
ORP – Oxidation Reduction Potential |
The scale |
±2000 mV |
Resolution |
0.1 mV |
|
Accuracy |
±0.2 mV |
|
Relative mV offset |
±2000 mV |
|
ISE |
The scale |
1 x 10⁻7 up to 9.99 x 10¹⁰ concentration |
Resolution |
3 digits 0.01, 0.1, 1, 10 concentration |
|
Accuracy |
±0.5% value (I-valence), ±1% value (II-valence) |
|
Calibration |
Up to 5 points with 6 available standards (0.1, 1, 10, 100, 1000, 10000) |
|
Channel 1 Temperature |
The scale |
-20.0 to 120.0 ºC (-4.0 to 248.0 °F) |
Resolution |
0.1 °C/ 0.1 °F |
|
Accuracy |
±0.2 °C, ±0.4 °F; ±0.2 K (excluding probe error) |
|
Calibration Slope |
From 80 to 110% |
|
Electrode |
pH/ORP/ISE electrode with BNC connector See more BNC port electrode list at: https://www.hannavietnam.com/detailcate/cong-bnc-192 |
|
Temperature probe |
RCA connection port Recommended probes: HI7662-TW |
|
EC – Conductivity |
The scale |
0 to 400 mS/cm (displays values up to 1000 mS/cm) Actual conductivity 1000 mS/cm 0.001 to 9.999 μS/cm 10.00 to 99.99 μS/cm 100.0 to 999.9 μS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 999.9 mS/cm 1000 mS/cm (automatic scale) |
Resolution |
0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm, 1 mS/cm |
|
Accuracy |
±1% measured value (±0.01 μS/cm or 1 digit, whichever is greater) (excluding probe error) |
|
Calibration |
– Up to 2 points with 7 standard solutions 0.00 μS/cm, 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm |
|
Set cell number row |
0.010 to 10.000 |
|
TDS – Total Dissolved Solids |
The scale |
0.000 to 9.999 ppm (mg/L) 10.00 to 99.99 ppm (mg/L) 100.0 to 999.9 ppm (mg/L) 1.000 to 9.999 ppt (g/L) 10.00 to 99.99 ppt (g/L) 100.0 to 400.0 ppt (g/L) (automatic scale) |
Resolution |
0.001 ppm, 0.01 ppm, 0.1 ppm, 0.001 g/L, 0.01 g/L, 0.1 g/L |
|
Accuracy |
±1% value (±0.01 ppm or 1 digit, whichever is greater) excluding probe error |
|
Impedance |
The scale |
1.0 to 99.9 ohms; 100 to 999 ohms; 1.00 to 9.99 Kohms; 10.0 to 99.9 Kohms; 100 to 999 Kohms; 1.00 to 9.99 Mohms; 10.0 to 100.0 Mohms (automatic scale) |
Resolution |
0.1 ohm; 1 ohm; 0.01 Kohms; 0.1 Kohms; 1 Kohms; 0.01 Mohms; 0.1 Mohms |
|
Accuracy |
±1% value (± 10 ohms or 1 digit, whichever is greater) (excluding probe error) |
|
Salinity – NaCl |
The scale |
%NaCl: 0.0 to 400.0% |
Resolution |
0.1% |
|
Accuracy |
± 1% measured value excluding probe error |
|
Calibration |
Maximum 1 point (HI7037 purchased separately) |
|
Channel 2 Temperature |
The scale |
-20.0 to 120.0 ºC (-4.0 to 248.0 °F) |
Resolution |
0.1 °C/ 0.1 °F |
|
Accuracy |
±0.2 °C (excluding probe error) |
|
EC probe |
DIN port |
|
Heat source |
Automatic Handmade |
|
EC temperature compensation |
NoTC, MTC, ATC |
|
Reference temperature |
15, 20, 25 °C |
|
Temperature coefficient |
0.00 to 10.00 %/ °C |
|
TDS Factor |
0.40 to 1.00 |
|
Input channel |
pH/mV/ISE and temperature (CHANNEL 1) EC/TDS, NaCl/Impedance and Temperature (CHANNEL 2) |
|
Save data on demand |
400 samples |
|
Record by lot |
5, 10, 30 seconds 1, 2, 5, 10, 30, 60, 120, 180, AutoEnd (up to 600 samples) |
|
Electricity supply |
12V adapter (included) |
|
PC Interface |
Opto-isolated USB |
|
Environment |
0 to 50oC, RHmax 55% non-condensing |
|
Size |
235 x 207 x 110 mm |
|
Mass |
1.8 Kg |
|
Guarantee |
12 months (for products with intact tags and warranty card) |
|
Supply includes |
– HI3512 meter – 12V Adapter - Warranty – Quality certification – Carrying case + HI3512-01: 115V + HI3512-02: 230V HI3512 DOES NOT COMES WITH ELECTRODE |