Force and mechanical measuring equipment
Transition of the voltage value during AUTO examination and electric discharge level display.The electric discharge exceeds a threshold value level is displayed in red.
The electric discharge level in the applied voltage during AUTO test is displayed.It is graph-ization about partial discharge inception voltage (CSV) and partial discharge extinction voltage (CEV).
The electric discharge generating accumulation frequency characteristic in the electric discharge level generated
during AUTO test is displayed.
Inverter motor, Hybrid car power motor, Automotive motor
HV transformer for power supply, Switchingpowersupply transformer for household appliances
Power semiconductor, Insulated film, Evaluation of the charge of an insulation material, etc.
Power supply | Test voltage & capacity | Maximum5000Vrms 500VA |
---|---|---|
Minimum variable step | 4Vrms | |
Test frequency | 50Hz/60Hz ( Set up at 1Hz step is possible in 50~200Hz) | |
Partial discharge inspection. inspection |
Detection sensitivity | -90~-30dBm |
Detection result display | -90 to -30dbm indicates as 100 level | |
Detection charge range | 50pC or more as a relative level. | |
Antenna cable | Standard 2m (SMA coaxial cable) | |
Voltage measurement | Voltage display | 0~5000Vrms(Effective value ) |
Measurement accuracy | ±1.5% of reading | |
Current leakage detection | Current disruption | 1~ 25mA(1mA step) or 100mA |
General | Input power supply V. | AC100~240V±5% 50Hz/60Hz 10A |
Temperature/humidity | 23℃±5℃ 20% – 80%RH | |
Size/Weight | W430×H177×D442 ※About 22kg | |
External interface | Parallel I/O、RS-232C、USB(Test control, test data input and output |
► We also have calibration certificate attached ( optional )
► Please re-calibrate after use for a certain period through our purchase store.
DISTRIBUTED BY:
Semiki instrumentation Co., Ltd
Email: sales@semiki.com
Office tel: +84 28 2253 3522
~DOING OUR BEST FOR YOU~