Force and mechanical measuring equipment
– Can be used with pH electrode as a desktop pH meter
– Measure up to 40 ion parameters in clean water
– Transfer PC data using USB cable.
– Use adapter and rechargeable battery conveniently.
– The screen has a bright backlight.
– Record data automatically.
– Has wavelength calibration mode for high accuracy.
+ HI83300-01 : 115V
+ HI83300-02: 230V
MODERN FEATURES OF METER
FULL LIGHT ANALYSIS MACHINE IN CLEAN WATER
The HI83300 benchtop photometer measures up to 40 different important water quality parameters over a wide range.
Simply select the required measurement method using the METHOD button.
CONVENIENT WHEN MEASUREMENT IN THE FIELD
The machine uses a power adapter directly with an internal 3.7 VDC Lithium-polymer rechargeable battery when out in the field.
DATA RECORDING AND DATA TRANSFER WITH USB PORT
2 USB ports are provided for transferring data to a flash drive or computer and can be used as a power source.
Up to 1000 measurements can be recorded with user and sample ID.
Data is exported as a .CSV file for use with popular spreadsheet programs.
LARGER CUVET DESIGN
The HI83300 sample cell fits a 25 mm diameter glass cuvette. Coupled with advanced optical components, the larger cuvette size significantly reduces cuvette indexing errors. The relatively long cuvette length allows more light to pass through the sample solution, ensuring accurate measurements even in low absorbance samples.
BACKLIGHT SCREEN
128 x 64 Pixel LCD graphic display with backlight support in low light conditions.
CAL CHECK FUNCTIONTM
CAL Check featureTM Hanna's proprietary technology allows independent measurement channel performance verification.
CAL Check standard set HI83300-11 by HANNA was developed to simulate a specific absorbance value at each wavelength 420 nm, 466 nm, 525 nm, 575 nm and 610 nm to verify the accuracy of the machine. This is useful for users with their own chemistry methods and for educators to teach absorbance concepts using the Beer-Lambert Law.
HI83The 300 is designed with an advanced optical system incorporating a beam splitter so that the light can be used for absorption values and for a reference detector. The reference detector monitors the light intensity and adjusts for disturbances due to electrical or thermal fluctuations of the optical components. Each part has an important role to play in providing excellent performance from a photometer.
Features as a Desktop pH Meter
(When connecting the optional PH electrode)
BECOME A PROFESSIONAL DESKTOP pH METER
– When connecting the 3.5mm digital pH electrode to the meter and switching to pH mode, the HI83300 will have all the features of a professional benchtop pH meter.
– pH scale from -2.00 to 16.00 and sample temperature measured simultaneously.
AUTOMATIC CALIBRATION AND TEMPERATURE COMPENSATION
Selecting the pH measurement mode allows the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic point calibration and GLP.
The scale |
-2.00 to 16.00 pH |
Resolution |
0.1 pH |
Accuracy |
±0.01 pH |
Calibration |
Automatic at 1 or 2 points at 4.01, 6.86, 7.01, 9.18, 10.01 |
Heat compensation |
Auto (-5.0 to 100.0 oC; 23.0 to 212.0 oF); depending on the pH electrode used |
CAL Check |
Clean electrode and check buffer/probe display during calibration |
pH electrode |
Compatible with 3.5mm digital pH electrode (purchased separately when pH measurement is required) HANNA electrode types: https://hannavietnam.com/detailcate/ky-thuat-so-35mm-204 |
Note |
pH electrode and accessories for pH measurement such as magnetic stirrer, stand, calibration solution purchased separately |
MEASUREABLE OPTICAL INDICATORS
Measure any target and buy reagents for that target
Parameter |
The scale |
Resolution |
Accuracy |
Reagent code |
Low range ammonium |
0.00 to 3.00 mg/L NH3-N |
0.01 mg/L |
±0.04 mg/L ±4% measurement result |
HI93700-01 (100 measurements) |
Medium scale ammonium |
0.00 to 10.00 mg/L NH3-N |
0.01 mg/L |
±0.05 mg/L ±5% measurement result |
HI93715-01 (100 measurements) |
High range ammonium |
0.0 to 100.0 mg/L NH3-N |
0.1 mg/L |
±0.5 mg/L ±5% measurement result |
HI93733-01 (100 measurements) Video HI93733-01 |
Surface active agent, anionic |
0.00 to 3.50 mg/L SDBS |
0.01 mg/L |
±0.04 mg/L ±3% measurement result |
HI95769-01 (40 measurements) |
Cyanuric acid |
0 to 80 mg/L CYA |
1mg/L |
±1 mg/L ±15% measurement result |
HI93722-01 (100 measurements) |
Silver |
0.000 to 1.000 mg/L Ag |
0.001 mg/L |
±0.020 mg/L ±5% measurement result |
HI93737-01 (50 measurements) |
Brom |
0.00 to 8.00 mg/L Br2 |
0.01 mg/L |
±0.08 mg/L ±3% measurement result |
HI93716-01 (100 measurements) Video HI93716-01 |
Calcium (soft drink) |
0 to 400 mg/L Ca2+ |
1mg/L |
±10 mg/L ±5% measurement result |
HI937521-01 (50 measurements) |
Calcium (sea water) |
200 to 600 mg/L Ca2+ |
1mg/L |
±6% measurement result |
HI758-26 (25 measurements) |
Chloride |
0.0 to 20.0 mg/L Cl– |
0.1 mg/L |
±0.5 mg/L ±6% measurement result |
HI93753-01 (100 measurements) |
Chlorine dioxide |
0.00 to 2.00 mg/L ClO2 |
0.01 mg/L |
±0.10 mg/L ±5% measurement result |
HI93738-01 (100 measurements) |
Chlorine dioxide (quick method) |
0.00 to 2.00 mg/L ClO2 |
0.01 mg/L |
±0.10 mg/L ±5% measurement result |
HI96779-01 (100 measurements) |
Residual chlorine |
0.00 to 5.00 mg/L Cl2 |
0.01 mg/L |
±0.03 mg/L ±3% measurement result |
HI93701-01 (100 measurements) Video on how to measure HI93701 |
Ultra low residual chlorine |
0.000 to 0.500 mg/L Cl2 |
0.001 mg/L |
±0.020 mg/L ±3% measurement result |
HI95762-01 (100 measurements) |
Total chlorine |
0.00 to 5.00 mg/L Cl2 |
0.01 mg/L |
±0.03 mg/L ±3% measurement result |
HI93711-01 (100 measurements) |
Super low total chlorine |
0.000 to 0.500 mg/L Cl2 |
0.001 mg/L |
±0.020 mg/L ±3% measurement result |
HI95761-01 (100 measurements) |
Super high total chlorine |
0 to 500 mg/L Cl2 |
1mg/L |
±3 mg/L ±3% measurement result |
HI95771-01 (100 measurements) |
High-grade Chromium VI |
0 to 1000 μg/L Cr6+ |
1 μg/L |
±5 μg/L ±4% measurement result |
HI93723-01 (100 measurements) |
Low level Chromium VI |
0 to 300 μg/L Cr6+ |
1 μg/L |
±1 μg/L ±4% measurement result |
HI93749-01 (100 measurements) |
Deoxidizer (yes) |
0 to 1000 μg/L DEHA O2 |
1 μg/L |
±5 μg/L ±5% measurement result |
HI96773-01 (50 measurements) |
Deoxidizer (carbohydrazide) |
0.00 to 1.50 mg/L O2 (Carbohydrazide) |
0.01 mg/L |
±0.02 mg/L ±3% measurement result |
HI96773-01 (50 measurements) |
Deoxidizer (hydroquinone) |
0.00 to 2.50 mg/L2 (Hydroquinone) |
0.01 mg/L |
±0.04 mg/L ±3% measurement result |
HI96773-01 (50 measurements) |
Deoxidizer (iso-ascorbic acid) |
0.00 to 4.50 mg/L O2 (ISO-ascorbic acid) |
0.01 mg/L |
±0.03 mg/L ±3% measurement result |
HI96773-01 (50 measurements) |
Color of water |
0 to 500 PCU |
1 PCU |
±10 PCU ±5% measurement result |
No reagents required |
High level |
0.00 to 5.00 mg/L Cu |
0.01 mg/L |
±0.02 mg/L ±4% measurement result |
HI93702-01 (100 measurements) |
Low level |
0.000 to 1.500 mg/L Cu |
0.001 mg/L |
±0.010 mg/L ±5% measurement result |
HI95747-01 (100 measurements) |
Low ladder fluorine |
0.00 to 2.00 mg/L– |
0.01 mg/L |
±0.03 mg/L ±3% measurement result |
HI93729-01 (100 measurements) |
High level fluorine |
0.0 to 20.0 mg/L– |
0.1 mg/L |
±0.5 mg/L ±3% measurement result |
HI93739-01 (100 measurements) |
Low total stiffness |
0 to 250 mg/L CaCO3 |
1mg/L |
±5 mg/L ±4% measurement result |
HI93735-00 (100 measurements) Video HI93735-02 |
Average total hardness |
200 to 500 mg/L CaCO3 |
1mg/L |
±7 mg/L ±3% measurement result |
HI93735-01 (100 measurements) Video HI93735-02 |
High total stiffness |
400 to 750 mg/L CaCO3 |
1mg/L |
±10 mg/L ±2% measurement result |
HI93735-02 (100 measurements) Video HI93735-02 |
Calcium hardness |
0.00 to 2.70 mg/L CaCO3 |
0.01 mg/L |
±0.11 mg/L ±5% measurement result |
HI93720-01 (100 measurements) |
Magnesium hardness |
0.00 to 2.00 mg/L CaCO3 |
0`01 mg/L |
±0.11 mg/L ±5% measurement result |
HI93719-01 (100 measurements) Magnesium hardness measurement video |
Hydrazine |
0 to 400 μg/LN2H4 |
1 μg/L |
±4%FS |
HI93704-01 (100 measurements) |
Potassium |
0.0 to 20.0 mg/mL |
0.1 mg/L |
±3.0 mg/L ±7% measurement result |
HI93750-01 (100 measurements) Video measurement HI93750-01 |
Zinc |
0.00 to 3.00 mg/L Zn |
0.01 mg/L |
±0.03 mg/L ±3% measurement result |
HI93731-01 (100 measurements) |
Alkaline (sea water) |
0 to 300 mg/L CaCO3 |
1mg/L |
±5 mg/L ±5% measurement result |
HI755-26 (25 measurements) |
Alkaline (fresh water) |
0 to 500 mg/L CaCO3 |
1mg/L |
±5 mg/L ±5% measurement result |
HI775-26 (25 measurements) HI775-26 measurement video |
Iodine |
0.0 to 12.5 mg/LI2 |
0.1 mg/L |
±0.1 mg/L ±5% measurement result |
HI93718-01 (100 measurements) HI93718-01 Measurement Video |
Magnesium |
0 to 150 mg/L Mg2+ |
1mg/L |
±5 mg/L ±3% measurement result |
HI937520-01 (50 measurements) |
High manganese |
0.0 to 20.0 mg/L Mn |
0.1 mg/L |
±0.2 mg/L ±3% measurement result |
HI93709-01 (100 measurements) |
Low level manganese |
0 to 300 μg/L Mn |
1 μg/L |
±10 μg/L ±3% measurement result |
HI93748-01 (50 measurements) |
Molybdenum |
0.0 to 40.0 mg/L Mo6+ |
0.1 mg/L |
±0.3 mg/L ±5% measurement result |
HI93730-01 (100 measurements) |
High grade nickel |
0.00 to 7.00 g/L Ni |
0.01 g/L |
±0.07 g/L ±4% measurement result |
HI93726-01 (50 measurements) |
Low grade nickel |
0.000 to 1.000 mg/L Ni |
0.001 mg/L |
±0.010 mg/L ±7% measurement result |
HI93740-01 (50 measurements) Video HI93740-01 |
Nitrate |
0.0 to 30.0 mg/L NO3–-N |
0.1 mg/L |
±0.5 mg/L ±10% measurement result |
HI93728-01 (100 measurements) Video HI93728-01 |
High level freshwater nitrite |
0 to 150 mg/L NO2– |
1mg/L |
±4 mg/L ±4% measurement result |
HI93708-01 (100 measurements) |
Low level freshwater nitrite |
0 to 600 μg/L NO2–-N |
1 μg/L |
±20 μg/L ±4% measurement result |
HI93707-01 (100 measurements) |
Ultra low seawater nitrite |
0 to 200 μg/L NO2–-N |
1 μg/L |
±10 μg/L ±4% measurement result |
HI764-25 (25 measurements) |
Aluminum |
0.00 to 1.00 mg/L Al3+ |
0.01 mg/L |
±0.04 mg/L ±4% measurement result |
HI93712-01 (100 measurements) |
pH |
6.5 to 8.5 pH |
0.1 pH |
±0.1 pH |
HI93710-01 (100 measurements) |
High level phosphate (soft drink) |
0.0 to 30.0 mg/L PO43- |
0.1 mg/L |
±1 mg/L ±4% measurement result |
HI93717-01 (100 measurements) Video: HI93717-01 |
Low range phosphate (soft drink) |
0.00 to 2.50 mg/L PO43- |
0.01 mg/L |
±0.04 mg/L ±4% measurement result |
HI93713-01 (100 measurements) Video: HI93713-01 |
Ultra low scale phosphate (water) |
0 to 200 μg/LP |
1 μg/L |
±5 μg/L ±5% measurement result |
HI736-25 (25 measurements) |
Dissolved oxygen (DO) |
0.0 to 10.0 mg/L2 |
0.1 mg/L |
±0.4 mg/L ±3% measurement result |
HI93732-01 (100 measurements) |
Ozone |
0.00 to 2.00 mg/L3 |
0.01 mg/L |
±0.02 mg/L ±3% measurement result |
HI93757-01 (100 measurements) |
High ladder iron (total iron) |
0.00 to 5.00 mg/L Fe |
0.01 mg/L |
±0.04 mg/L ±2% measurement result |
HI93721-01 (100 measurements) |
Low ladder iron (total iron) |
0.000 to 1.600 mg/L Fe |
0.001 mg/L |
±0.010 mg/L ±8% measurement result |
HI93746-01 (50 measurements) |
Iron II |
0.00 to 6.00 mg/L Fe2+ |
0.01 mg/L |
±0.10 mg/L ±2% measurement result |
HI96776-01 (100 measurements) |
Iron II/III |
0.00 to 6.00 mg/L Fe |
0.01 mg/L |
±0.10 mg/L ±2% measurement result |
HI96777-01 (100 measurements) |
Low scale silica |
0.00 to 2.00 mg/L SiO2 |
0.01 mg/L |
±0.03 mg/L ±3% measurement result |
HI93705-01 (100 measurements) Video HI93705-01 |
High-grade silica |
0 to 200 mg/L SiO2 |
1mg/L |
±1 mg/L ±5% measurement result |
HI96770-01 (100 measurements) |
Sulfate |
0 to 150 mg/L SO42- |
1mg/L |
±5 mg/L ±3% measurement result |
HI93751-01 (100 measurements) |
METER SPECIFICATIONS
pH electrode |
Digital pH electrode (purchased separately) |
Recording type |
Record as required with username and sample ID |
Recording memory |
1000 samples |
Connect |
USB-A host for flash drives; micro-USB-B for power and computer connectivity |
GLP |
Calibration data for pH electrode |
Screen |
128 x 64 backlit LCD |
The battery |
3.7VDC rechargeable battery |
Electricity supply |
5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) |
Environment |
0 to 50°C (32 to 122°F); max 95% RH non-condensing |
Size |
206 x 177 x 97 mm |
Mass |
1.0kg |
Light source |
5 LEDs 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm |
Light probe |
Silicon photodetector |
Bandpass Filter Bandwidth |
8 nm |
Bandpass Filter Wavelength Accuracy |
±1 nm |
Cuvette |
24.6mm round (16mm digestion tube) |
Number of methods |
68 |
Guarantee |
12 months |
Supply includes |
– HI83300 meter – 4 cuvettes with lids – Cuvette cleaning cloth - USB cable – Adapter - User manual – Certification of the quality of the measuring machine REAGENTS PURCHASED SEPARATELY FOR EACH INDICATOR |
Order code |
HI83300-01: 115V HI83300-02: 230V |