Home / Shop / New Generation pH and Multiparameter Photometer in Clean Water HI83300-02
Product portfolio

New Generation pH and Multiparameter Photometer in Clean Water HI83300-02

Producer:
SKU: HANNA-HI83300-02 Category:

– Can be used with pH electrode as a desktop pH meter

– Measure up to 40 ion parameters in clean water 

– Transfer PC data using USB cable.

– Use adapter and rechargeable battery conveniently.

– The screen has a bright backlight.

– Record data automatically.

– Has wavelength calibration mode for high accuracy.

   + HI83300-01 : 115V

   + HI83300-02: 230V

MODERN FEATURES OF METER

 

FULL LIGHT ANALYSIS MACHINE IN CLEAN WATER

The HI83300 benchtop photometer measures up to 40 different important water quality parameters over a wide range.

Simply select the required measurement method using the METHOD button. 

CONVENIENT WHEN MEASUREMENT IN THE FIELD

The machine uses a power adapter directly with an internal 3.7 VDC Lithium-polymer rechargeable battery when out in the field.

 

 

 

 

DATA RECORDING AND DATA TRANSFER WITH USB PORT

2 USB ports are provided for transferring data to a flash drive or computer and can be used as a power source.

Up to 1000 measurements can be recorded with user and sample ID. 

Data is exported as a .CSV file for use with popular spreadsheet programs.

 

 

 

 

 

LARGER CUVET DESIGN 

The HI83300 sample cell fits a 25 mm diameter glass cuvette. Coupled with advanced optical components, the larger cuvette size significantly reduces cuvette indexing errors. The relatively long cuvette length allows more light to pass through the sample solution, ensuring accurate measurements even in low absorbance samples.

 

 

 

 

BACKLIGHT SCREEN 

128 x 64 Pixel LCD graphic display with backlight support in low light conditions.

 

 

 

CAL CHECK FUNCTIONTM

CAL Check featureTM Hanna's proprietary technology allows independent measurement channel performance verification.

CAL Check standard set HI83300-11 by HANNA was developed to simulate a specific absorbance value at each wavelength 420 nm, 466 nm, 525 nm, 575 nm and 610 nm to verify the accuracy of the machine. This is useful for users with their own chemistry methods and for educators to teach absorbance concepts using the Beer-Lambert Law.

 

 

 

ADVANCED OPTICAL SYSTEM

HI83The 300 is designed with an advanced optical system incorporating a beam splitter so that the light can be used for absorption values and for a reference detector. The reference detector monitors the light intensity and adjusts for disturbances due to electrical or thermal fluctuations of the optical components. Each part has an important role to play in providing excellent performance from a photometer.

 

 

Features as a Desktop pH Meter

 (When connecting the optional PH electrode)

 

BECOME A PROFESSIONAL DESKTOP pH METER

– When connecting the 3.5mm digital pH electrode to the meter and switching to pH mode, the HI83300 will have all the features of a professional benchtop pH meter.

– pH scale from -2.00 to 16.00 and sample temperature measured simultaneously.

AUTOMATIC CALIBRATION AND TEMPERATURE COMPENSATION

Selecting the pH measurement mode allows the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic point calibration and GLP. 

 

 

The scale

-2.00 to 16.00 pH

Resolution

0.1 pH

Accuracy

±0.01 pH

Calibration

Automatic at 1 or 2 points at 4.01, 6.86, 7.01, 9.18, 10.01

Heat compensation

Auto (-5.0 to 100.0 oC; 23.0 to 212.0 oF); depending on the pH electrode used

CAL Check

Clean electrode and check buffer/probe display during calibration

pH electrode

Compatible with 3.5mm digital pH electrode (purchased separately when pH measurement is required)

    HANNA electrode types: https://hannavietnam.com/detailcate/ky-thuat-so-35mm-204

Note

pH electrode and accessories for pH measurement such as magnetic stirrer, stand, calibration solution purchased separately

MEASUREABLE OPTICAL INDICATORS

Measure any target and buy reagents for that target

YouTube video

Parameter

The scale

Resolution

Accuracy

Reagent code

Low range ammonium

0.00 to 3.00 mg/L NH3-N

0.01 mg/L

±0.04 mg/L

±4% measurement result

HI93700-01 

(100 measurements)

Medium scale ammonium

0.00 to 10.00 mg/L NH3-N

0.01 mg/L

±0.05 mg/L

±5% measurement result

HI93715-01 

(100 measurements)

High range ammonium

0.0 to 100.0 mg/L NH3-N

0.1 mg/L

±0.5 mg/L

±5% measurement result

HI93733-01 (100 measurements)

Video HI93733-01

Surface active agent, anionic

0.00 to 3.50 mg/L SDBS

0.01 mg/L

±0.04 mg/L

±3% measurement result

HI95769-01

(40 measurements)

Cyanuric acid

0 to 80 mg/L CYA

1mg/L

±1 mg/L

 ±15% measurement result

HI93722-01 

(100 measurements)

Silver

0.000 to 1.000 mg/L Ag

0.001 mg/L

±0.020 mg/L

±5% measurement result

HI93737-01 

(50 measurements)

Brom

0.00 to 8.00 mg/L Br2

0.01 mg/L

±0.08 mg/L

 ±3% measurement result

HI93716-01 

(100 measurements)

Video HI93716-01

Calcium (soft drink)

0 to 400 mg/L Ca2+

1mg/L

±10 mg/L

±5% measurement result

HI937521-01 

(50 measurements)

Calcium (sea water)

200 to 600 mg/L Ca2+

1mg/L

±6% measurement result

HI758-26 

(25 measurements)

Chloride

0.0 to 20.0 mg/L Cl

0.1 mg/L

±0.5 mg/L

±6% measurement result

HI93753-01 

(100 measurements)

Chlorine dioxide

0.00 to 2.00 mg/L ClO2

0.01 mg/L

±0.10 mg/L

±5% measurement result

HI93738-01 

(100 measurements)

Chlorine dioxide

(quick method)

0.00 to 2.00 mg/L ClO2

0.01 mg/L

±0.10 mg/L

±5% measurement result

HI96779-01

(100 measurements)

Residual chlorine

0.00 to 5.00 mg/L Cl2

0.01 mg/L

±0.03 mg/L

±3% measurement result

HI93701-01 

(100 measurements)

Video on how to measure HI93701

Ultra low residual chlorine

0.000 to 0.500 mg/L Cl2

0.001 mg/L

±0.020 mg/L

±3% measurement result

HI95762-01 

(100 measurements)

Total chlorine

0.00 to 5.00 mg/L Cl2

0.01 mg/L

±0.03 mg/L

±3% measurement result

HI93711-01 

(100 measurements)

Super low total chlorine

0.000 to 0.500 mg/L Cl2

0.001 mg/L

±0.020 mg/L

±3% measurement result

HI95761-01

(100 measurements)

Super high total chlorine

0 to 500 mg/L Cl2

1mg/L

±3 mg/L

±3% measurement result

HI95771-01

(100 measurements)

High-grade Chromium VI

0 to 1000 μg/L Cr6+

1 μg/L

±5 μg/L

±4% measurement result

HI93723-01 

(100 measurements)

Low level Chromium VI

0 to 300 μg/L Cr6+

1 μg/L

±1 μg/L

±4% measurement result

HI93749-01

(100 measurements)

Deoxidizer

(yes)

0 to 1000 μg/L DEHA O2

1 μg/L

±5 μg/L

±5% measurement result

HI96773-01

(50 measurements)

Deoxidizer

(carbohydrazide)

0.00 to 1.50 mg/L O(Carbohydrazide)

0.01 mg/L

±0.02 mg/L

±3% measurement result

HI96773-01

(50 measurements)

Deoxidizer

(hydroquinone)

0.00 to 2.50 mg/L2 (Hydroquinone)

0.01 mg/L

±0.04 mg/L

±3% measurement result

HI96773-01

(50 measurements)

Deoxidizer

(iso-ascorbic acid)

0.00 to 4.50 mg/L O(ISO-ascorbic acid)

0.01 mg/L

±0.03 mg/L

±3% measurement result

HI96773-01

(50 measurements)

Color of water

0 to 500 PCU

1 PCU

±10 PCU

±5% measurement result

No reagents required

High level

0.00 to 5.00 mg/L Cu

0.01 mg/L

±0.02 mg/L

 ±4% measurement result

HI93702-01 

(100 measurements)

Low level

0.000 to 1.500 mg/L Cu

0.001 mg/L

±0.010 mg/L

 ±5% measurement result

HI95747-01

(100 measurements)

Low ladder fluorine

0.00 to 2.00 mg/L

0.01 mg/L

±0.03 mg/L

±3% measurement result

HI93729-01 

(100 measurements)

High level fluorine

0.0 to 20.0 mg/L

0.1 mg/L

±0.5 mg/L

±3% measurement result

HI93739-01 

(100 measurements)

Low total stiffness

0 to 250 mg/L CaCO3

1mg/L

±5 mg/L

±4% measurement result

HI93735-00 

(100 measurements)

Video HI93735-02

Average total hardness

200 to 500 mg/L CaCO3

1mg/L

±7 mg/L

±3% measurement result

HI93735-01 

(100 measurements)

Video HI93735-02

High total stiffness

400 to 750 mg/L CaCO3

1mg/L

±10 mg/L

±2% measurement result

HI93735-02 (100 measurements)

Video HI93735-02

Calcium hardness

0.00 to 2.70 mg/L CaCO3

0.01 mg/L

±0.11 mg/L

 ±5% measurement result

HI93720-01 

(100 measurements)

Magnesium hardness

0.00 to 2.00 mg/L CaCO3

0`01 mg/L

±0.11 mg/L

±5% measurement result

HI93719-01 

(100 measurements)

Magnesium hardness measurement video

Hydrazine

0 to 400 μg/LN2H4

1 μg/L

±4%FS

HI93704-01 

(100 measurements)

Potassium

0.0 to 20.0 mg/mL

0.1 mg/L

±3.0 mg/L

±7% measurement result

HI93750-01 (100 measurements)

Video measurement HI93750-01

Zinc

0.00 to 3.00 mg/L Zn

0.01 mg/L

±0.03 mg/L

 ±3% measurement result

HI93731-01 

(100 measurements)

Alkaline (sea water)

0 to 300 mg/L CaCO3

1mg/L

±5 mg/L

 ±5% measurement result

HI755-26 

(25 measurements)

Alkaline (fresh water)

0 to 500 mg/L CaCO3

1mg/L

±5 mg/L

 ±5% measurement result

HI775-26 (25 measurements)

HI775-26 measurement video

Iodine

0.0 to 12.5 mg/LI2

0.1 mg/L

±0.1 mg/L

±5% measurement result

HI93718-01 (100 measurements)

HI93718-01 Measurement Video

Magnesium

0 to 150 mg/L Mg2+

1mg/L

±5 mg/L

 ±3% measurement result

HI937520-01

(50 measurements)

High manganese

0.0 to 20.0 mg/L Mn

0.1 mg/L

±0.2 mg/L

±3% measurement result

HI93709-01 

(100 measurements)

Low level manganese

0 to 300 μg/L Mn

1 μg/L

±10 μg/L

 ±3% measurement result

HI93748-01 

(50 measurements)

Molybdenum

0.0 to 40.0 mg/L Mo6+

0.1 mg/L

±0.3 mg/L

 ±5% measurement result

HI93730-01

(100 measurements)

High grade nickel

0.00 to 7.00 g/L Ni

0.01 g/L

±0.07 g/L

 ±4% measurement result

HI93726-01

(50 measurements)

Low grade nickel

0.000 to 1.000 mg/L Ni

0.001 mg/L

±0.010 mg/L

±7% measurement result

HI93740-01 (50 measurements)

Video HI93740-01

Nitrate

0.0 to 30.0 mg/L NO3-N

0.1 mg/L

±0.5 mg/L

±10% measurement result

HI93728-01  (100 measurements)

Video HI93728-01

High level freshwater nitrite

0 to 150 mg/L NO2

1mg/L

±4 mg/L

±4% measurement result

HI93708-01 

(100 measurements)

Low level freshwater nitrite

0 to 600 μg/L NO2-N

1 μg/L

±20 μg/L

 ±4% measurement result

HI93707-01 

(100 measurements)

Ultra low seawater nitrite

0 to 200 μg/L NO2-N

1 μg/L

±10 μg/L

 ±4% measurement result

HI764-25 

(25 measurements)

Aluminum

0.00 to 1.00 mg/L Al3+

0.01 mg/L

±0.04 mg/L

 ±4% measurement result

HI93712-01 

(100 measurements)

pH

6.5 to 8.5 pH

0.1 pH

±0.1 pH

HI93710-01 

(100 measurements)

High level phosphate

(soft drink)

0.0 to 30.0 mg/L PO43-

0.1 mg/L

±1 mg/L

±4% measurement result

HI93717-01 (100 measurements)

Video: HI93717-01

Low range phosphate

(soft drink)

0.00 to 2.50 mg/L PO43-

0.01 mg/L

±0.04 mg/L

±4% measurement result

HI93713-01 (100 measurements)

Video: HI93713-01

Ultra low scale phosphate

(water)

0 to 200 μg/LP

1 μg/L

±5 μg/L

±5% measurement result

HI736-25

(25 measurements)

Dissolved oxygen (DO)

0.0 to 10.0 mg/L2

0.1 mg/L

±0.4 mg/L

±3% measurement result

HI93732-01 

(100 measurements)

Ozone

0.00 to 2.00 mg/L3

0.01 mg/L

±0.02 mg/L

 ±3% measurement result

HI93757-01 

(100 measurements)

High ladder iron

(total iron)

0.00 to 5.00 mg/L Fe

0.01 mg/L

±0.04 mg/L

±2% measurement result

HI93721-01 

(100 measurements)

Low ladder iron

(total iron)

0.000 to 1.600 mg/L Fe

0.001 mg/L

±0.010 mg/L

±8% measurement result

HI93746-01 

(50 measurements)

Iron II

0.00 to 6.00 mg/L Fe2+

0.01 mg/L

±0.10 mg/L

±2% measurement result

HI96776-01

(100 measurements)

Iron II/III

0.00 to 6.00 mg/L Fe

0.01 mg/L

±0.10 mg/L

±2% measurement result

HI96777-01

(100 measurements)

Low scale silica

0.00 to 2.00 mg/L SiO2

0.01 mg/L

±0.03 mg/L

±3% measurement result

HI93705-01 (100 measurements)

Video HI93705-01

High-grade silica

0 to 200 mg/L SiO2

1mg/L

±1 mg/L

±5% measurement result

HI96770-01 

(100 measurements)

Sulfate

0 to 150 mg/L SO42-

1mg/L

±5 mg/L

 ±3% measurement result

HI93751-01 

(100 measurements)

METER SPECIFICATIONS

pH electrode

Digital pH electrode (purchased separately)

Recording type

Record as required with username and sample ID

Recording memory

1000 samples

Connect

USB-A host for flash drives; micro-USB-B for power and computer connectivity

GLP

Calibration data for pH electrode

Screen

128 x 64 backlit LCD

The battery

3.7VDC rechargeable battery

Electricity supply

5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)

Environment

0 to 50°C (32 to 122°F); max 95% RH non-condensing

Size

206 x 177 x 97 mm

Mass

1.0kg 

Light source

5 LEDs 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm

Light probe

Silicon photodetector

Bandpass Filter Bandwidth

8 nm

Bandpass Filter Wavelength Accuracy

±1 nm

Cuvette

24.6mm round (16mm digestion tube)

Number of methods

68

    Guarantee

12 months

Supply includes

– HI83300 meter

– 4 cuvettes with lids

– Cuvette cleaning cloth

- USB cable

– Adapter

- User manual

– Certification of the quality of the measuring machine

REAGENTS PURCHASED SEPARATELY FOR EACH INDICATOR

Order code

HI83300-01: 115V

HI83300-02: 230V

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.