Force and mechanical measuring equipment
The Mitutoyo LSM-6902H laser measuring system exhibits the best repeatability in its 25mm/1 in. product class. The Mitutoyo LSM Series LSM-6902H/6900 laser scan micrometer uses an ultra-precise scanning engine to achieve high accuracy, ideal for sensitive or moving parts. The LSM-6902H series is an excellent choice for measuring rollers or measuring tips.
SPECIFICATIONS LSM-6902H/6900
Model LSM-6902H/6900
120V AC 544-499-1A
Acceptable standard of laser IEC (FDA: 544-499-1A)
Measuring range 0.1 – 25mm (.004″ – 1.0″)
Resolution (selectable) 0.00001 – 0.01mm (.000001″ – .0005″)
Repeatability*1 +/-0.045µm (dia. 25mm),
+/-0.03µm (dia. 10mm)
Linearity
at 20°C*2
Entire range ±0.5µm (±20µinch)
Narrow range ±(0.3+0.1ΔD)µm*5
Positional error*3 ±0.5µm (±20µinch)
Measuring region*4 +/- 1.5 x 25 (+/-0.06×1.0”)
Scanning rate 3200/sec
Laser wavelength 650nm, Visible*6
Laser scanning speed 226m/sec (8898”/sec)
Operating temperature 0°C – 40°C
Operating humidity 35 – 85% RH (with no condensation)
Mass Measuring unit: 6.0kg (13.2lbs.),
Signal cable: 0.5kg (1.1lbs.)
Type inch/mm
Display 16-digit fluorescent tube (for measurement) &
11-digit fluorescent tube (sub display)
Segment designation Seg.1 to Seg.7 (Seg.1 – Seg.3 for transparent
objects)
Edge designation 1 to 255 edges can be detected
Averaging times Arithmetical average: per 2 to 2048, moving
average: per 32 to 2048
Go/no-go judgment Nominal value ±tolerance setting, upper & lower
limits setting, multi-limit setting
Measurement mode Waiting, single measurement, continuous
measurement. measurement
Statistical calculation Maximum measurement (MAX), minimum
measurement (MIN), mean, range (MAX-MIN),
standard deviation (σ)
Power supply 120V AC ±10%, 60Hz, 40VA
Data output (as standard) Via RS-232C and I/O-Analog interfaces
Functions (See pages 16 and 17.)
Operating temperature 0°C – 40°C
Operating humidity 35 – 85% RH (with no condensation)
Mass 5kg (11lbs.)
*1: Determined by the value for ±2σ at the measurement of ø25mm workpiece with 1.28sec.
interval (1024-time avarage).
*2: At the center of the measuring region.
*3: An error due to workpiece shift either in the optical axis direction or in the scanning direction.
*4: The area given by “measuring range on the optical axis” x “measuring range in the scanning
direction.”
*5: ΔD=Difference in diameter between the master gage and workpiece in mm.
*6: FDA Class II/IEC Class 2 semiconductor laser for scanning (Maximum power: 1.0mW)
Pin and plug gage measurements
Factory-set package
Maintenance and calibration :
► We also have calibration certificate attached ( optional )
► Please re-calibrate after use for a certain period through our purchase store. Local Vietnam : SEMIKI CORP
DISTRIBUTED BY:
Semiki instrumentation Co., Ltd
Email: sales@semiki.com
Office tel: +84 28 2253 3522
~DOING OUR BEST FOR YOU~