Semiki logo
HOTLINE: +84 979761016
0

Cart

No products in the cart.

Continue shopping
Home / Shop / Membrane Caps for HI76409 and HI76410 Electrodes (5 Pieces) HI76409A/P
Product portfolio

Membrane Caps for HI76409 and HI76410 Electrodes (5 Pieces) HI76409A/P

Producer:
SKU: HANNA-HI76409A/P Category:

Screw design

PTFE Membrane Cap

For use with HI76409 or HI76410 galvanic electrodes

Easy to refill HI7042S electrolyte

Purchase at:

        

The HI76409A/P are dissolved oxygen membrane caps designed specifically for the probe and galvanic sensor of Hanna's portable dissolved oxygen meter. The cap is made of ABS plastic with a HDPE membrane. The membrane cap is designed to be easily filled with electrolyte solution and installed onto the probe. The membrane cap separates the cathode and anode of the probe from the water being measured. Oxygen diffuses through the membrane and interacts with the galvanic system to produce a current that measures oxygen concentration. Each cap is designed to be easily filled with HI7042 electrolyte solution and screwed onto the probe.

HOW TO REPLACE MEMBRANE FOR ELECTRONS

YouTube video

 PROPERLY STORE THE MEMBRANE WHEN NOT IN USE

YouTube video

HI76409A/P

Material

ABS plastic with HDPE membrane

Specifications

5 membrane caps with O-rings 

Using

1. Rinse the HI76409A/P membrane cap with a small amount of HI7042S electrolyte solution, shaking gently while rinsing.

2. Place the O-ring in the correct position on the inside of the membrane cover.

3. Fill the HI7042S bottle with fresh electrolyte solution.

4. Use your finger to gently tap the edge of the membrane cap to ensure there are no trapped air bubbles. Do not tap the membrane directly from the bottom up to avoid damaging the membrane. 

5. With the sensor tip facing down, screw the membrane cap onto the probe clockwise. A few drops of electrolyte solution will spill out to be exact. 

Methods of preservation

– BStore membrane caps at room temperature, away from direct sunlight.

– Do not reuse the old membrane cap after inserting it into the electrode.

– Always use fresh HI7042S electrolyte solution 

 When not in use and during polarization, remove the membrane cap and discard the old electrolyte solution inside, then dry the probe and cover the probe with the red and black transport cap originally supplied..

THE ELECTRODE WILL OXIDATE AND BE COMPLETELY DAMAGED IF THE ELECTROLYTE SOLUTION IS LEFT UNUSED FOR TOO LONG TIME.

Use for 

– HI76409 electrode

– HI76410 electrode

– HI9147 meter

Guarantee

Are not

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.