Force and mechanical measuring equipment
ANRITSU handheld electronic thermometer is made in Japan with high quality and accuracy in measurement.
Model HR-1150K belongs to the convenient HR thermometer series with high accuracy, reliability and ease of use. Combined with a variety of Anritsu Meter temperature probes, it supports many different applications such as measuring solution temperature, measuring contact surface temperature.
Code | HR-1150 | ||
Display screen | LCD | ||
Waterproof specifications | Equivalent to IPX5 | ||
Input connector | ANP | ||
Input type | Thermocouple input: Type E, K | ||
Channel | 1ch | ||
Signal source resistor | MAX.1k ohm | ||
Measurement range | Resolution 1°C | E | -200 to 800°C |
K | -200 to 1370°C | ||
Resolution 0.1°C | E | -104.9 to 504.9°C
(Automatically switches to 1°C resolution range when the turbulence temperature is outside the 0.1°C resolution range.) |
|
K | -104.9 to 504.9°C
(Automatically switches to 1°C resolution range when the turbulence temperature is outside the 0.1°C resolution range.) |
||
Measurement accuracy | Resolution 1°C | 0°C to | ± (0.1% reading +1°C) |
to 0°C | ± (0.5% reading +1°C) | ||
Resolution 0.1°C | 0°C to | ± (0.05% reading + 0.2°C) | |
to 0°C | ± (0.15% reading + 0.2°C) | ||
Reference point compensation accuracy | ±0.2°C at 25°C±10°C | ||
Temperature coefficient*1 | ±0.02×Δt°C (Add the value obtained by multiplying the residual temperature.Δt[°C] by the factor for total accuracy. e.g. ±0.5°C is added at room is 0°C or 50°C) | ||
Operating environment | 0 to 50°C, 0 to 80%RH (No condensation) | ||
Storage environment | -20 to 50°C, 0 to 85%RH (No condensation) | ||
Battery life | about 900 hours | ||
Power source (Dry battery) | 4 AA alkaline batteries | ||
Power source (AC power) | – | ||
Sampling rate | about 200ms | ||
linearization | Digital Linearization Method (Compliant with JIS C1602-2015) | ||
Dimensions (mm) | approx. 82(w)×166(H)×36(D) [Excluding protrusions] | ||
Weight | about 350g [Battery included] | ||
Accessories included | User manual, Test report, Soft case, | ||
Wrist strap, 4 AA Alkaline batteries | |||
Compatible standards | EMC:EN61326-1:2013, EN 61326-2-1:2013 class A Table 2(Industrial)RoHS: IEC EN 63000: 2018 |
*1 Only when temperature. exceeds 25°C±10°C
OPTIONAL ACCESSORIES
Detachable temperature probe compatible with HR-1150K
Pic: Anritsu Stationary Suface Probes A-231K-01-1-TC1-ANP (type K/ -50°C to 500°C)
at SEMIKI warehouse.
Maintenance and calibration:
► We also have a calibration certificate included (optional)
► Please recalibrate after using for a certain period of time through our purchase store.
In Viet Nam: SEMIKI inc.
DISTRIBUTED BY:
Semiki instrumentation Co., Ltd
Email: sales@semiki.com
Office tel: +84 28 2253 3522
~DOING OUR BEST FOR YOU~