ni USB-6225 80 channel signal collector

Producer:

USB-6225 Multi-Function I/O Device 80 AI (16-Bit, 250 kS/s), 2 AO (833 kS/s), Up to 24 DIO USB Multi-Function I/O Device —The USB‑6225 provides analog I/O, digital I/O, two 32-bit counters/timers, and digital triggering. It provides reliable, low-cost DAQ capabilities in a wide range of applications from simple lab automation, research, design verification/checking, and manufacturing testing. You can add sensor and high-voltage measurement capabilities to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurement.

NATIONAL INSTRUMENTS (ni)

Multifunction I/O Device
Model: USB-6225

Multifunction I/O Device USB-6225 80 AI (16-Bit, 250 kS/s), 2 AO (833 kS/s), Up to 24 DIO USB
—The USB‑6225 offers analog I/O, digital I/O, two 32‑bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

Features:

  • Up to 80 Analog Inputs at 16 bits, 1.25 MS/s (1 MS/s or 750 KS/s Scanning)
  • Up to 4 Analog Outputs at 16 bits, 2.8 MS/s (2 µs full-scale settling)
  • Up to 48 TTL/CMOS Digital I/O Lines (Up to 32 Hardware-Timed at Up to 1 MHz)
  • Two 32-bit, 80 MHz Counter/Timers

National Instruments USB-6225 Multifunction I/O Device  

The USB-6225 (Part Numbers: 779974-01779973-02779973-04779973-01779974-04) is a Multifunction I/O Device created by National Instruments. This device provides superior accuracy along with fast sampling rates. This device has 80 analog input channels. These channels can be used as 80 single-ended channels. The user can also utilize these channels as 40 differential channels. The NI USB-6225 offers 16-bit ADC resolution and the maximum sample rate of 250 kS/s for a single channel. For multiple channels, the maximum sample rate is also 250 kS/s. The timing accuracy of the input channels is 50 ppm of the sample rate. The device has a recommended warm-up time of 30 minutes, and should be calibrated at least once a year.

The USB 6225 NI has different input ranges. The input ranges include ±0.2V, ±1V, ±5V, and ±10V. The value of maximum working voltage for analog inputs of this device is ±11V. The input FIFO size for this device is 4,095 samples. The NI USB-6225 DAQ provides an overvoltage protection for all analog input channels and all sense channels. The input current of this instrument during the overvoltage condition is ±20 mA maximum.

The NI USB-6225 M Series DAQ has two analog output channels. Both channels provide 16 bit DAC resolution. The analog output channels have 16-bit monotonicity. The maximum update rate for one output channel is 833 kS/s. For both channels, the maximum update rate is 740 kS/s. The timing accuracy of the output channels is 50 ppm of the sample rate. The output range of this device is ±10 V. The output impedance is 0.2 Ω. The output channels provide an overdrive protection up to ±25 Volts.

The screw terminal fitted model of the device weighs 2 lb, and measures 10.5 x 6.73 x 1.75 in. in physical dimensions. Also, the Mass termination model weighs 2 lb, and has the physical dimensions: 7.4 x 6.73 x 1.75 in. The NI device has recommended operating and storage temperature ranges of 0 ºC to 45 ºC and -20 ºC to 70 ºC respectively, and a noncondensing humidity range of 10% RH to 90% RH.

– SEMIKI is happy to share Technical and Solutions relating to metrology, measuring, precision gages, manufacturing quality control and processes.

For complete product information, visit :

www.semiki.com

www.ni.com.vn

Maintenance and calibration : 

► We also have calibration certificate attached ( optional )

► Please re-calibrate after use for a certain period through our purchase store.

Local Vietnam : SEMIKI CORP

DISTRIBUTED BY:

Semiki instrumentation Co., Ltd

Email: sales@semiki.com

Office tel: +84 9797 61016

~DOING OUR BEST FOR YOU~

 

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.