Semiki logo
HOTLINE: +84 979761016
0

Cart

No products in the cart.

Continue shopping
Home / Shop / Optical measuring equipment / Colorimeter / SEKONIC C-7000 Handheld industrial spectrometer
Product portfolio

SEKONIC C-7000 Handheld industrial spectrometer

Producer:
Category: Tag:

The C-7000 is a compact and lightweight spectrometer that can be carried into the field. By adopting a linear CMOS image sensor for spectral sensing, an important factor affecting performance, the C-7000 can accurately measure various light sources such as LED, organic EL, HMI, fluorescent lamp optical and natural light, etc. In addition, Sekonic's exclusive technology allows flash light to be measured using spectroscopy. This device can measure different types of light regardless of the light source.

・Ability to export spectral data (1 nm and 5 nm wavelength, unit: W・m-2・nm-1) as CSV

・Measurement items and display modes are suitable for industrial use

・All-in-one handheld device can display, record and graph measured values

・Measuring flash light using the spectroscopic method thanks to the unique accumulation type sensor

・User-friendly product design with 270° head rotation mechanism and capless dark calibration

・Many rich color rendering evaluation modes

(CRI, TM-30-18, TLCI/TLMF, SSI)

・PPFD (Photosynthetic Photon Flux Density) can be confirmed for plant growing plants

・Calibration certificate, test report, traceability system diagram can be issued (fees apply)

Purpose of use SEKONIC C-7000

・Color rendering index, correlated color temperature, illuminance, dominant wavelength, and excitation purity can be measured for various types of lighting such as LEDs, organic ELs, and projectors.

・Measurement of automotive LED headlights and various lamps

・Illuminance measurement of photobiological reactions

・Confirmation of the illuminance and the spectral distribution of the light source at plant factories

・Illuminance/color temperature/color rendering evaluation of road lighting, indoor lighting, store lighting, etc.

・Color temperature and color rendering evaluation of medical lighting equipment

・Color temperature and color rendering evaluation of lighting equipment for color evaluation

・Color temperature and color rendering evaluation of lighting equipment for visual inspection

・Lighting management for museums, office environments, etc.

・Illuminance, color temperature, and color rendering evaluation of special lighting for broadcasting stations, studios, stages, etc.

Recommended customers

・Customers engaged in quality control, research and development, etc. for LEDs, organic ELs, projectors, etc.

・Customers who design and install lighting for buildings, offices, etc.

・Customers engaged in the selection and management of lighting equipment with high color rendering

・Customers managing grow lights used in plant factories

FEATURES

Measurement capabilities for various light sources
(LED, organic EL, HMI, fluorescent light, tungsten light, natural light, flash light, etc.)
The C-7000 uses a CMOS linear image sensor in the light receiving section. Spectroscopic measurement is performed in the wavelength range of 380nm to 780nm to obtain an accurate color temperature.

It can accurately measure not only conventionally used flash light and constant light sources (fluorescent light, tungsten light, HMI, etc.), but also light sources such as LEDs and organic ELs, which have been increasing in recent years.


  • Figure 1. Conventional filter method
    Measure the wavelength range covered by the RGB filter

  • Figure 2. C-7000
    A CMOS linear image sensor equipped with an LVF covers the measurement wavelength range with a fine pitch.

 

Original optical design for the light receiving partSpectrometer C-7000 makes full use of optical technology in the light receiving part. We remove infrared rays that are not necessary for measuring and adjusting the angle of light. In addition to the use of a dedicated CMOS linear image sensor, a unique optical system minimizes measurement errors caused by oblique incident light. It also incorporates a newly developed thin dark correction unit and ND filter. Dark calibration and high-intensity flash measurement can be switched simply by rotating the light selection ring.

Various display modesIn addition to the text mode that displays measured values numerically and the spectrum mode that displays the wavelength of the light source, various display modes such as CRI mode, 5 color rendering evaluation modes, chromaticity diagram mode (CIE1931, CIE1976), chromaticity diagram comparison mode (CIE1931, CIE1976), etc. are available.

Display Mode Selection Screen


  • Page 1

  • Page 2

You can quickly switch between display modes by touching the icon on the main screen.

Page 1: Each measurement mode

Page 2: Comparison mode and settings

  • Text Mode
    Text Mode
    In text mode, the measured values ​​are displayed numerically. You can freely select or replace 5 items that can be displayed. PPFD display is also available.
  • Spectrum Mode
    Spectrum Mode
    Display the spectrum graph. Full-screen display of the graph is also possible.
  • Spectrum Comparison Mode
    Spectrum Comparison Mode
    Up to two saved data can be recalled, and the current measured values ​​and spectrographs can be compared with the recalled data.
  • CRI Mode

    Ra and color rendering index from R1 to R15 are displayed graphically and numerically. You can select and display the index that you want to know in particular.
  • CRI Comparison Mode

    It is possible to compare the color rendering index between the memory value and the current measured value.
  • TM-30 Mode

    Based on the 99 standard colors and the characteristics of the human eye, Rf (fidelity index) and Rg (gamut index) are displayed as indices. Displayed numerically and in color vector graphics.
  • CIE1931 Mode

    Displays the CIE1931 (x, y) chromaticity coordinates in a chromaticity diagram and numerical values. By switching the field of view to 10 degrees, the CIE1964 chromaticity diagram (x10, y10) is displayed.
  • CIE1931 Comparison Mode

    Up to two saved data can be recalled, and the current measured values ​​​​and the recalled data can be compared on the CIE1931 chromaticity diagram.
  • CIE1976 Mode

    Display CIE1976(u', v') chromaticity coordinates in chromaticity diagram and numerical values.
  • CIE1976 Comparison Mode

    Up to two saved data can be recalled, and the current measured value and the recalled measured value can be compared on the CIE1976 diagram.

 Abundant measurement items and wide measurement rangeAbundant measurement items such as color temperature (K), deviation (⊿uv), illuminance (lx), photosynthetic photon flux density (PPFD), chromaticity (xy), color rendering index CRI (Ra, R1~R15) and the latest color rendering properties (Rf, Rg, TLCI, TLMF, SSIt, SSId) are available. In addition, it has a wide measurement range of 1,563 to 100,000 K (Tcp) and 1 to 200,000 lx in ambient light, and 2,500 to 100,000 K (Tcp) and 20 to 20,500 lx・s in flash light.

  • Measurement item
    selection screen
  • Color rendering index (CRI)
    display item selection screen

Selectable measurement methodIt is possible to select the measurement method “single measurement” or “continuous measurement” in the tool box. Continuous measurement is performed continuously from the start of measurement to the end of measurement.

  •  Toolbox screen
  • Measurement method
    selection screen

CustomizationThe C-7000 can be customized according to the application and environment.

  • Setting page 1
  • Setting page 2

Utility software for C-7000You can do the following by connecting the PC and C-7000 with a USB cable and using the dedicated utility software.

・Confirmation of C-7000 information such as firmware version information

・C-7000 settings (toolbox, custom function change, preset data edit, hardware settings, initialization)

・Import data saved in the C-7000 to a PC.

・Spectral data (every 5 nm and 1 nm) can be imported to a PC in CSV format

・Graph display (Jpeg, BMP, PNG format files) and data saving

・C-7000 firmware update

・Supported OS for C-7000 utility software: Windows and Macintosh

  • Main Screen
  • Memory Data Management
  • CSV of Spectral Data
  • Spectral Distribution
  • CIE1931, CIE1964
    Chromaticity Diagram
  • CIE1976 Chromaticity Diagram
  • CRI
  • TM-30

Provide SDK for developersWe provide SDK for developers who want to remotely control the C-7000, allowing them to freely develop measurement systems according to their needs.
(SDK will be provided with manual and sample software. We don't provide other technical support for SDK.)
*Users who want to be provided with the SDK should contact us using the inquiry form. Our sales representative will contact you shortly.

Provide Excel add-in software for remote controlFor customers who want to use ready made software to control the C-7000 remotely, we provide Excel add-in software.
(We don't provide technical support for Excel add-in software.)
*Users who want to be provided with the Excel add-in software should contact us using the inquiry form. Our sales representative will contact you shortly.

Parts Designations

SPECIFICATION

Type Spectrometer with CMOS linear image sensor
Illuminance meter class Conforms to JIS C 1609-1:2006 for General Class A Illuminance Meters
Conforms to DIN 5032 Part 7 Class C
Light receiving method Incident light
Light receptors White diffuser (fixed type)
Light receptor element CMOS linear image sensor 128 pixels
Measurement system Measuring mode Ambient light Ambient light mode
Flash light Cord (PC) Flash mode
Cordless Flash mode
Display mode Text mode, Spectrum mode, Spectrum Comparison mode, CRI mode, CRI Comparison mode, TM-30 mode, SSI mode, TLCI/TLMF mode, CIE1931 (CIE1964) mode, CIE1931 (CIE1964) Comparison mode, CIE1976 mode, CIE1976 Comparison mode
Measuring item Tcp(Correlated Color temperature)、
⊿uv(Deviation)、
X, Y, Z / X10, Y10, Z10(Tristimulus value)、
x, y, z / x10, y10, z10(CIE1931(CIE1964)Chromaticity coordinates)
u',v'/u'10,v'10(CIE1976 Uniform Chromaticity Scale)
λd / λd,10(Dominant wavelength)
Pe / Pe,10(Excitation purity)
λp(Peak wavelength)
Lux, fc(Illuminance)/Hlx, Hfc(luminous exposure)
Ra(Average Color Rendering Index)
R1~R15(Special Color Rendering Index)
Rf, Rg
SSIt, SSId
TLCI
TLMF
PPFD(Photosynthetic Photon Flux Density)
Measurement range Illuminance Ambient light 1lx to 200,000lx
0.1fc to 18,600fc
Luminous exposure Flash light Range L: 20lx·s to 640lx·s (f/2.8 to f/16)
Range H: 580lx·s to 20,500lx·s (f/11.9 to f/90)
Photosynthetic Photon Flux Density 0.0 to 9999.9μmol m-2S-1
Color rendering properties CRI Ra, R1 to R15 -100.0 to 100.0
TM-30 RF 0 to 100
Rg 0 to 200
SSI SSI 0 to 100
TLCI-2012 Qa 0 to 100
TLMF-2013 ⊿Qa 0 to 100(5lx to 200,000lx = 0.46fc to 18,600fc)
Accuracy Illuminance ±5% ±1digit of indicated value※twelfth
(Complies with JIS C1609-1:2006 general A class illuminometer)
xy ±0.003 (Light source A, 800lx)
Repeatability (2σ) Illuminance 1% + 1digit (Light source A, 30lx to 200,000lx), ※3
5% + 1digit (Light source A, 1lx to 29.9lx)※3
xy 0.001(Light source A, 500lx to 200,000lx)※1 ※4
0.002(Light source A, 100lx to 499lx)※1 ※4
0.004(Light source A, 30lx to 99lx)※1 ※4
0.008(Light source A, 5lx to 29.9lx)※1 ※4
Spectral response characteristics f1' 9% or less (Complies with JIS C1609-1:2006 general A class illuminometer)
Oblique incident light characteristics f2 6% or less (Complies with JIS C1609-1:2006 general A class illuminometer)
Temperature characteristics Illuminance ±5% of indicated value (Complies with JIS C1609-1:2006 general A class illuminometer)
xy ±0.006 (Light source A, 1000lx)※first
Humidity characteristics Illuminance ±3% of indicated value (Complies with JIS C1609-1:2006 general A class illuminometer)
xy ±0.006 (Light source A, 1000lx)※first
Display range Color temperature 1,563K to 100,000K (5lx to 200,000lx)
Illuminance Ambient light 1lx to 200,000lx (3 significant digits)
Luminous exposure Flash light 20 lx·s to 20,500 lx·s, 1.86 fc·s to 1,900 fc·s (3 significant digits)
Shutter speed Flash light 1 second to 1/500 second
Color rendering properties CRI Ra, R1 to R15 -100.0 to 100.0
TM-30 RF 0 to 100
Rg 0 to 200
SSI SSI 0 to 100
TLCI-2012 Qa 0 to 100
TLMF-2013 ⊿ Qa 0 to 100 (5lx to 200,000lx = 0.46fc to 18,600fc)
Other functions Preset settings Preset 1 to 5 settings
Setting 6 item settings
Memory function Up to 999 measurements or titles
Memory clear/recall function
Out of measurement range or out of display range [Under]/[Over] warning display
Battery capacity indicator display With 4 level status icons
Automatic power OFF function Time elapsed after last operation: selectable from 20min., 10min., 5min., none
LCD backlight Brightness can be selected from bright, normal, or dark
Dimmer time after last operation: selectable from about 5seconds, about 10seconds, about 20seconds, about 40seconds, about 60seconds, none
Touch panel lock function Hold MENU button down for 3 seconds to lock and unlock.
Tripod socket 1/4-inch, 20 threads
display LCD display resolution 4.3 inches QVGA 480×800 dots
Recommended battery AA batteries 1.5V × 2 alkaline, manganese
Power Supply USB bus-power
5V/500mA or less (via USB cable when connected to computer)
(Limited Power Source or Class 2 Power Source)
Operating temperature -10°C to 40°C (without condensation)
Operating humidity 85%RH or less (at 35°C) (without condensation)
Transportation and storage conditions -10°C to 60°C (without condensation)
Dimensions Approx. 73 (width) × 183 (height) × 27 (depth) mm
(excluding protruding part of light receiving) (max. thickness 40mm)
Weight approx. 230g (without batteries)
Included accessories CD-ROM (this Operating Manual and applications (Win, Mac)), Soft case, Strap, Start-up Guide, Safety Precaution, Safety Requirement and Precaution, USB Cable (Mini-B connector)

* Models sold in some countries do not display illuminance and exposure in “fc (fc·s)” due to legal restrictions. In this case, Unit of Illuminance is not displayed.

* Specifications and appearance described in this Operating Manual are subject to change without prior notice for improvement.

※1: When the measurement mode is ambiant light (range L) and the exposure time is auto.
※2: Illuminance is linear.
※3: The error is the value obtained by dividing 2σ of 10 measurements by the average value.
※4: The error is the maximum value minus the minimum value of 10 measurements.

STANDARD ACCESSORIES

・Startup Guide

・Strap

・Soft Case

・USB Mini-B cable (1m)

・CD-ROM (Utility software/Software guide/Operating manual)

MAINTENANCE AND CALIBRATION : 

► We also have calibration certificate attached ( optional )
► Please re-calibrate after use for a certain period through our purchase store.

Local Vietnam : SEMIKI CORP

DISTRIBUTED BY:

Semiki instrumentation Co., Ltd
Email: sales@semiki.com
Office tel: +84 28 2253 3522

~DOING OUR BEST FOR YOU~

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.