Discontinued, Replaced by TESTO 300
The testo 310 flue gas analyzer with precise readings, sturdy design and ease of use is what a technician wants for quick and reliable testing of heating and mechanical systems.
What are the advantages of the testo 310 flue gas meter?
The testo 310 has easy-to-use measurement menus stored in the instrument. Four integrated menus for flue gas, draught, ambient CO and pressure measurements. The testo 310 also has a large, easy-to-read display with integrated backlighting for use in all lighting conditions.
But that's not all, of course. The compact testo 310 flue gas analyzer has a range of useful features that make it a great assistant for technicians.
- The integrated magnet on the back allows you to attach the testo 310 securely to metal surfaces.
- Sensor zero time less than 30 seconds
- The sensor filter can be easily replaced.
- Sturdy design helps protect the device from unexpected impacts
- Integrated condensation trap (anti-fog)
- Testo fast printer (optional order): enables you to print measurement data on site via infrared communication
>>> Youtube: Here
>>> Fanpage: Here
>>> News: Here
Specifications
General specifications |
Weight |
700 g |
Size |
201 x 83 x 44 mm |
Operating temperature |
-5 to +45 °C |
Screen |
LCD (Liquid Crystal Display) |
Display function |
2-line backlit display |
Power supply |
Battery: 1500 mAh, 5V / 1A power supply |
Storage temperatures |
-20 to +50 °C |
Temperature – TC Type K (NiCr-Ni) |
Measuring range |
-20 to +100 °C |
Accuracy |
±1 °C |
Resolution |
0.1 °C |
Response time |
<50 seconds |
Temperature – TC Type J (Fe-CuNi) |
Measuring range |
0 to +400 °C |
Accuracy |
±1 °C (0 to +100 °C)
±1.5 % measured value (> 100 °C)
|
Resolution |
0.1 °C |
Response time |
<50 seconds |
O₂ gas |
Measuring range |
0 to 21 Vol.% |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Response time t₉₀ |
30 seconds |
Differential Pressure Draft – Piezoresistive |
Measuring range |
-20 to +20 hPa |
Accuracy |
±0.03 hPa (-3.00 to +3.00 hPa)
±1.5 % measured value (Remaining measuring range)
|
Resolution |
0.01 hPa |
Furnace efficiency, Eta (calculated) |
Measuring range |
0 to 120% |
Resolution |
0,1% |
Emission loss (calculation) |
Measuring range |
0 to 99.9% |
Resolution |
0,1% |
CO₂ gas (from O₂) |
Measuring range |
0 to CO₂ max (Display range) |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Response time t₉₀ |
<40 seconds |
Pressure Gauge |
Measuring range |
-40 to +40 hPa |
Accuracy |
±0.5hPa |
Resolution |
0.1 hPa |
CO gas (without H₂ compensation) |
Measuring range |
0 to 4000 ppm |
Accuracy |
±20 ppm (0 to 400 ppm)
±5 % measured value (401 to 2000 ppm)
±10 % measured value (2001 to 4000 ppm)
|
Resolution |
1 ppm |
Response time t₉₀ |
60 seconds |
Ambient CO |
Measuring range |
0 to 4000 ppm |
Accuracy |
±20 ppm (0 to 400 ppm)
±5 % measured value (401 to 2000 ppm)
±10 % measured value (2001 to 4000 ppm)
|
Resolution |
1 ppm |
Response time |
60 seconds |