  • testo 330-2 LL flue gas analyzer with long-life gas sensor, draft and zeroing
  • With BLUETOOTH and H2 compensated CO sensor
  • Includes rech. Testo batteries and device calibration papers
  • Graphic screen
  • 2010 version

Discontinued, Replaced by TESTO 300

Thanks to new instrument functions, the Testo flue gas analyzer of the new testo 330-LL flue gas analyzer series now offers you even more professional and reliable support. These are the main features

  • High-resolution color display for visual representation of your measurement data
  • Extensive measurement menus – such as gas pipe testing – for comprehensive analysis of your heating system
  • Logging function for easy long-term recording of the measurement curve

>>> Youtube: Here

>>> Fanpage: Here

>>> News: Here

Technical specifications of testo 330 -2 LL exhaust gas meter

Measure differential pressure

Measuring range ± 10,000 Pa
Accuracy ±0.3 Pa (0 to 9.99 Pa) ±1 digit
±3 % of measured value (10 to 10,000 Pa) ±1 digit

O gas2

Measuring range 0 to 21 Vol.%
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Response time t₉₀ < 20 s

CO gas measurement (H₂ compensation)

Parameter
Measuring range 0 to 8,000 ppm
Accuracy ±10 ppm or ±10 % of measured value (0 to 200 ppm)
±20 ppm or ±5 % of measured value (201 to 2,000 ppm)
±10 % of measured value (2001 to 8,000 ppm)
Resolution 1 ppm
Response time t₉₀ < 60 s

Measure COlow gas

Parameter
Measuring range 0 to 500 ppm
Accuracy ±2 ppm (0 to 39.9 ppm)
±5 % of measured value (40 to 500 ppm)
Resolution 0.1 ppm
Response time t₉₀ < 40 s

CO gas measurement (H₂ compensation), automatic dilution

Parameter
Measuring range 0 to 30,000 ppm
Accuracy ±100 ppm (0 to 1000 ppm)
±10 % of measured value (1001 to 30,000 ppm)
Resolution 1 ppm

Measure NO gas

Parameter
Measuring range 0 to 3,000 ppm
Accuracy ±5 ppm (0 to 100 ppm)
±5 % of measured value (101 to 2,000 ppm)
±10 % of measured value (2001 to 3,000 ppm)
Resolution 1 ppm
Response time t₉₀ < 30 s

Measure NOlow gas

Parameter
Measuring range 0 to 300 ppm
Accuracy ±2 ppm (0 to 39.9 ppm)
±5 % of measured value (40 to 300 ppm)
Resolution 0.1 ppm
Response time t₉₀ < 30 s

Measure Draft pressure

Parameter
Measuring range -9.99 to +40 hPa
Accuracy ±0.02 hPa or ±5 % of measured value (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of measured value (+3.01 to +40.00 hPa)
Resolution 0.01 hPa

.Temperature

Parameter
Measuring range -40 to +1200 °C
Accuracy ±0.5 °C (0 to +100.0 °C)
±0.5 % of measured value (remaining measuring range)
Resolution 0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C)

Combustion efficiency, Eta (calculated)

Parameter
Measuring range 0 to 120 %
Resolution 0,1 %

Furnace efficiency (calculated)

Parameter
Measuring range 0 to 99.9 %
Resolution 0,1 %

Calculate CO₂ (from O₂)

Parameter
Measuring range 0 to CO₂ max (display range)
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Response time t₉₀ < 40 s

Wind speed/air flow rate

Parameter
Measuring range 0.15 to 3 m/s
Resolution 0.1 m/s

CO gas measurement (No H₂ compensation)

Parameter
Measuring range 0 to 4,000 ppm
Accuracy ±20 ppm (0 to 400 ppm)
±5 % of measured value (401 to 2,000 ppm)
±10 % of measured value (2,001 to 4,000 ppm)
Resolution 1 ppm
Response time t₉₀ < 60 s

Ambient CO

Parameter
Measuring range 0 to 500 ppm
Accuracy ±5 ppm (0 to 100 ppm)
±5 % of measured value (> 100 ppm)
Resolution 1 ppm
Response time about. 35 s

With CO probe

Ambient CO₂

Parameter
Measuring range 0 to 1 Vol.%
0 to 10,000 ppm
Accuracy ±50 ppm or ±2 % of measured value (0 to 5,000 ppm)
±100 ppm or ±3 % of measured value (5,001 to 10,000 ppm)
Response time about. 35 s

With CO₂ probe

Leak measurement with flammable gases (via gas leak detection probe)

Parameter
Measuring range 0 to 10,000 ppm CH₄/ C₃H₈; Display range
Accuracy Signal optical display (LED) audible signal via buzzer
Response time t₉₀ < 2 s

With air leak detection probe

Temperature (via pressure probe)

Parameter
Measuring range -40 to +1200 °C max. (dependent on probe)
Accuracy ±0.5 °C (-40 to 100 °C)
±0.5 % of measured value (remaining measuring range) + probe accuracy
Resolution 0.1 °C

General specifications

Parameter
Guarantee Main equipment: 48 months; Probe: 48 months; Gas sensors (O₂, CO) 48 months; NO sensor 24 months; COlow sensor 24 months; Thermocouple 12 months; Rechargeable battery: 12 months
Screen resolution 240 x 320 pixels
Display screen Color screen
Power supply Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A
Maximum memory 500,000 measurement values
Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.