HIOKI PW3360 POWER RECORDER AND ANALYZER

Producer:

The HIOKI PW3360 power meter is a multi-channel power meter that uses clamp sensor input to accurately and safely measure power on single- to three-phase lines. The compact 3-phase 4-wire power data logger PW3360 monitors energy demand and other energy parameters to support energy audits and energy saving measure validation.

 

HIOKI CLAMP ON POWER LOGGER

 

MODEL: 
 
PW3360-20 : English model, main unit only
 
PW3360-21 : English model, with harmonic analysis function
 
HIOKI Clamp On Power Meters PW3360 are multi-channel power measuring devices utilizing clamp sensor input to accurately and safely measure power on single-phase to three-phase lines. The PW3360 compact 3-Phase 4-Wire energy loggers monitor power demand and other power parameters to aid in energy audits and validate energy saving measures.
 
Key Features:
 
Supports single to three-phase, 4-wire circuits
Measure between 90V to 780V
Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system)
Slim, compact design that can be placed anywhere
Store months of data on SD cards
The QUICK SET function guides you in making the right connections
Choose PW3360-21 for harmonic measurements up to the 40th order

 

 

 

 

Picture: HIOKI Clamp On Power Meters PW3360-20 Semiki's warehouse.

 

Specifications :

 

Measurement line & number of circuits 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
Measurement items Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead ), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input
[PW3360-21 only]: Harmonic voltage level, harmonic current level, harmonic power level, content percentage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th order
Voltage ranges 600 V AC (Effective measurement range: 90.00 V to 780.00 V)
Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use),
50,000 mA to 5,0000 A AC (Leak clamp on sensor only)
Power ranges 300.00 W to 9.0000 MW (depends on voltage/current combination and measured line type)
Basic accuracy Voltage : ±0.3% rdg. ±0.1% fs
Current : ±0.3% rdg. ±0.1% fs + clamp sensor accuracy
Active power : ±0.3% rdg. ±0.1% fs + clamp sensor accuracy (at power factor = 1)
Display update rate 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
Savedestination SD memory card, or internal memory at real time
Data save interval 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
Save items Measurement value saved: Average only / Average, Max./Min. value, [PW3360-21 only]: Harmonic data saved: Average only / average, max./min. value in binary format, Screen copy: BMP form (saved every 5 min. at minimum interval time), Waveform save: Binary waveform data
Interfaces SD/SDHC memory card
LAN 100BASE-TX: HTTP server function, remote settings via communication program, data download
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal
Functions Connection check, Quick Set navigation guide, clock, pulse input
Power supply AC Adapter Z1006: (100 to 240 V AC, 50/60 Hz), 40 VA (including AC adapter)
Battery Pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 8 hours of continuous use (with back light off)
Dimensions and mass 180 mm (7.09 in) W × 100 mm (3.94 in) H × 48 mm (1.89 in) D, 550 g (19.4 oz) without PW9002
180 mm (7.09 in) W × 100 mm (3.94 in) H × 67.2 mm (2.65 in) D, 830 g (29.3 oz) with PW9002
Accessories Voltage cord L9438-53 ×1 set, AC adapter Z1006 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip ×1 set: red, yellow, blue, white/two each, for color- coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5

 

 

 

video: The Hioki PW3360-20 Clamp On Power Logger is a 1P2W to 3P4W power logger with 2GB SD card data storage for energy audits and monitoring energy usage. 

Measure up to 780V, 5000A or 9MW of power to verify the effectiveness of energy saving initiatives. 

 

 

Maintenance and calibration : 

 

 We also have calibration certificate attached ( optional )

► Please re-calibrate after use for a certain period through our purchase store. Local Vietnam : SEMIKI CORP

 

DISTRIBUTED BY:

 

Semiki instrumentation Co., Ltd

Email: sales@semiki.com

Office tel: +84 28 2253 3522

 

 

~DOING OUR BEST FOR YOU~

 

 

 

Request a quote
SEMIKI MEASUREMENT EQUIPMENT COMPANY LIMITED
Headquarters:
  • Floor 12 – Tower A2, Viettel Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City, Vietnam
  • Sales@semiki.com
  • +84 979761016
  • Tax code 0313928935
Warranty, maintenance and repair center:
  • 10th Floor, Halo Building, 19-19/2A Ho Van Hue, Ward 9, Phu Nhuan District, HCMC
Representative office in Hanoi:
  • 9th Floor, 3D Building, No. 3 Duy Tan Street, Dich Vong Hau Ward, Cau Giay District, Hanoi City
© 2024 Semiki inc. All rights reserved.

Ask SEMIKI for a quote

Complete the form below to receive a quote from SEMIKI.
You need to enter all information fields below.