bộ hiệu chuẩn LDM TAKIKAWA L-032B, L-042B

Nhà sản xuất:

TAKIKAWA Laser Micrometer Calibration gauge and Calibration gauge Fixture

 

 

TAKIKAWA 

Laser Micrometer Calibration gauge 
and Calibration gauge Fixture

Model: 

L-032B (For LDM-303H-XY)

L-040 (For LDM-304H)

L-042B (For LDM-304H-XY)

L-022 (For LDM-302H-XY)

 

* Calibration gauge diameter can be changed according to customer’s request.

* The gauge diameter stated in the calibration gauge diameter is the diameter used in standard products.

Even if there is no diameter in this table, calibration may be possible if it is within the measurement range.

* Even not listed gauge diameters is also purchasable.

* Please contact our sales department  for the detector with the description of the option on the calibration gauge table.

 

 

 

Example of calibration method with Laser Micrometer (LDM-110 / LDM-210)

It is not necessary to calibrate the Laser Micrometer it is already calibrated at the time of shipment.
When calibration is necessary, 2 point calibration is performed with large diameter and small diameter. So prepare 2 gauge pins with different reference outside diameter.

 

For example, the procedure when using a gauge pin of Φ 40 mm as a large diameter and Φ 5 mm as a small diameter is shown.

Suppose the decimal point display of the main display is set to the second from the left. (88.888 display)

 

1. Set REF PRESET to “40.000”.

2. Set the gauge pin of Φ 40 mm as centered as possible in the measurement area of the Scanning Unit.

3. Push the HI switch of the CAL with a thing like a pin. (Please continue pushing for a while)

4. Release the CAL switch when the main display is displayed as “88888” and then “40000” is displayed. (This completes the calibration of Φ 40 mm)

5. Set REF PRESET to “05.000”.

6. Set the gauge pin of Φ 5 mm as centered as possible in the measurement area of the Scanning Unit.

7. Push the LO switch of the CAL with a thing like a pin. (Please keep pushing for a while)

8. Release the CAL switch when it is displayed as “88888” and then “05000” on the main display. (This completes the calibration of Φ 5 mm)

This completes the calibration between Φ 5 and 40 mm.

 

 

 

Maintenance and calibration : 

 

 We also have calibration certificate attached ( optional )

► Please re-calibrate after use for a certain period through our purchase store. Local Vietnam : SEMIKI CORP

 

 

 

 

DISTRIBUTED BY:

 

Semiki instrumentation Co., Ltd

Email:  sales@semiki.com

Office tel: +84 28 2253 3522

 

 

~DOING OUR BEST FOR YOU~

Yêu cầu báo giá
CÔNG TY TNHH THIẾT BỊ ĐO SEMIKI
Trụ sở chính:
  • Tầng 12 – tháp A2, Tòa nhà Viettel, 285 Cách Mạng Tháng Tám, Phường 12, Quận 10, Thành Phố Hồ Chí Minh, Việt Nam
  • Sales@semiki.com
  • +84 979761016
  • MST 0313928935
Trung tâm bảo hành, bảo trì và sửa chữa:
  • Lầu 10, Tòa nhà Halo, 19-19/2A Hồ Văn Huê, Phường 9, Quận Phú Nhuận, TP HCM
Văn phòng đại diện tại Hà nội:
  • Tầng 9 Tòa nhà 3D, Số 3 Phố Duy Tân, Phường Dịch Vọng Hậu, Quận Cầu Giấy, Thành phố Hà Nội
© 2024 Semiki inc. All rights reserved.

Yêu cầu SEMIKI báo giá

Hoàn thành biểu mẫu dưới đây để nhận báo giá từ SEMIKI.
Bạn cần nhập đủ tất cả các trường thông tin bên dưới.