High-Speed Waveform Data Transfer [Approx. 100 times faster (compared with former IWATSU models)],Touch Screen Operations,Japan Quality,1M-point long memory & high-speed startup,Superior cost performance. The observation of signal waveform is the most important function of oscilloscopes. ViewGo makes the best use of it’s first class design based on our long term experience in analog oscilloscope engineering
|
|
picture: IWASU DS-5554 in stock SEMIKI CORP
Specifications:
Parameter | DS-5514 | DS-5512 | DS-5524 | DS-5522 | DS-5534 | DS-5532 | DS-5554 | DS-5552 | |
Frequency bandwidth(-3dB) | 100MHz | 200MHz | 350MHz | 500MHz | |||||
Rise time(Typical) | 3.5ns | 1.75ns | 1ns | 750ps | |||||
Input Channel | 4 | 2 | 4 | 2 | 4 | 2 | 4 | 2 | |
Maximum Sampling Speed | 1GS/s | 1GS/s(all CHs)/ 2GS/s(Channel combined) | |||||||
Equivalent Sampling Rate | 100GS/s | ||||||||
Peak detect resolution | 1ns | ||||||||
Averaging | 2 to 256 times | ||||||||
Maximum Memory Length | 1Mpts/ch(for all CHs) | ||||||||
Vertical Resolution | 8-bit | ||||||||
Vertical System |
Range | 2mV/div – 10V/div(1Mohm) | 2mV/div – 10V/div(1Mohm),2mV/div – 2V/div(50ohm) | ||||||
Offset | 2mV/div – 50mV/div : +/-1V,50.2mV/div – 500mV/div : +/-10V,502mV/div – 10V/div : +/-100V | ||||||||
DC accuracy | +/- (1.5% + 0.5% of Full Scale) | ||||||||
Maximum Input Voltage | +/-400Vpeak CAT I( 1Mohm) | +/-400Vpeak CAT (1Mohm), 5Vrms( 50ohm) | |||||||
BW Limit | 20MHz | 20MHz,100MHz | |||||||
Input coupling | GND, DC 1Mohm, AC 1Mohm | GND, DC 1Mohm, AC 1Mohm, DC 50ohm | |||||||
Input Impedance | 1Mohm +/-1.0% // 20pF | 1Mohm +/-1.0% // 16pF,50ohm +/-1.0% | |||||||
Probe sense |
Automatic – 1:1,10:1,100:1, 1000:1, Manual – 1:1,5:1,10:1,20:1,50:1,100:1,200:1,500:1,1000:1, 2000:1 |
||||||||
Probe (one per channel) | SS-0130R | SS-101R | |||||||
Timebase | 5ns/div – 50s/div | 2ns/div – 50s/div | 1ns/div – 50s/div | 500ps/div – 50s/div | |||||
Roll mode | 50ms/div – 50s/div(100kS/s, max.) | ||||||||
Timebase (Clock) accuracy | 10ppm | ||||||||
Trigger Function | Edge, Edge ALT, Edge OR, Pulse Count, Pulse Width, Period, Dropout, TV, Pattern (OR,NOR,AND, NAND) | ||||||||
Trigger System |
TV mode | NTSC, PAL, Custom | |||||||
Line number select / Field select |
up to 3,000 / 1, 2, 4, 8 fields | ||||||||
Pulse Count Trigger |
1 to 9,999 events | ||||||||
Pulse Width Trigger |
15ns to 50s | ||||||||
Period Trigger | 40ns to 50s | ||||||||
Dropout Trigger | 50ns to 50s | ||||||||
Pattern Trigger | OR, NOR, AND, NAND | ||||||||
Trigger source / Status |
Input CHs / High , Low , Don’t-care | ||||||||
Trigger threshhold level setting |
Individually available for each CH | ||||||||
Trigger Source | Input CHs, Line, EXT(+/-0.5V), EXT10(+/-5.0V) | ||||||||
Trigger Coupling | AC, DC, HF Rej, LF Rej, Noise Rej | ||||||||
Display size/ resolution | 7.5inch color TFT-LCD with Touch screen / VGA(640*480pixels) | ||||||||
Display mode | Y-T, XY, XY (triggere |
Maintenance and calibration :
► We also have calibration certificate attached ( optional )
► Please re-calibrate after use for a certain period through our purchase store. Local Vietnam : SEMIKI CORP
DISTRIBUTED BY:
Semiki instrumentation Co., Ltd
Email: sales@semiki.com
Office tel: +84 28 2253 3522
~DOING OUR BEST FOR YOU~