- Nhà sản xuất : EVIDENT OLYMPUS
- Thickness Measurements on Plastics, Metals, Composites, Glass, Rubber, Ceramics
Chi tiết Sản phẩm
Key Features:
■ Dual and single element transducer compatibility
■ Wide thickness range: 0.08 mm (0.003 in.) to 635 mm
(25 in.) depending on material and transducer selection
■ Corrosion thickness gaging with dual element transducers
■ THRU-COAT® and Echo-to-Echo measurements on painted
and coated surfaces
■ Internal Oxide/Scale software option
■ Standard resolution of 0.01 mm or 0.001 in. for all
transducers
■ High Resolution software option of 0.001 mm or 0.0001 in.
with single element transducers 2.25 MHz to 30 MHz
■ Multilayer software option for measurements of up to four
layers simultaneously
■ High Penetration software option for attenuating materials
such as fberglass, rubber and thick casting
■ Thickness, Velocity, and time-of-flight measurements
■ Differential mode and Reduction Rate mode
■ Time-based B-scan mode; 10,000 reviewable readings per
scan
■ Olympus High Dynamic Gain technology with digital flters
■ V-Path Builder for custom V-path compensation
■ Designed for EN15317
Thickness Measurements on Plastics, Metals, Composites, Glass, Rubber, Ceramics
38DL PLUS Specifcations :
Dual element transducer measurement mode |
Time interval from a precision delay after the excitation pulse to the frst echo |
THRU-COAT® measurement |
Measurement of true metal and coating thicknesses with a single back-wall echo (with D7906-SM and D7908 transducers) |
Thru-Paint Echo-to-Echo | Time interval between two successive back-wall echoes to eliminate paint or coating thickness |
Single element transducer measurement modes |
Mode 1: Time interval between the excitation pulse and the frst back-wall echo Mode 2: Time interval between the delay line echo and the frst back-wall echo (with delay or immersion transducers) Mode 3: Time interval between successive back-wall echoes following the frst interface echo after the excitation pulse (with delay line or immersion transducers) Oxide: optional Multilayer mode: optional |
Thickness range | 0.080 mm to 635.00 mm (0.003 in. to 25.000 in.) depending on material, transducer surface conditions, temperature, and selected confguration |
Material velocity range | 0.508 mm/μs to 13.998 mm/μs (0.020 in./μs to 0.551 in./μs) |
Resolution (selectable) | Low: 0.1 mm (0.01 in.) Standard: 0.01 mm (0.001 in.) High Resolution (optional): 0.001 mm (0.0001 in.) |
Transducer frequency range |
Standard: 2.0 MHz to 30 MHz (–3 dB) High Penetration (optional): 0.50 MHz to 30 MHz (–3 dB) |
GENERAL | |
Operating temperature range |
–10 °C to 50 °C (14 °F to 122 °F) |
Keypad | Sealed, color-coded keypad with tactile and audible feedback |
Case | Impact-resistant and water-resistant, gasketed case with sealed connectors. Designed for IP67. |
Dimensions (W x H x D) | Overall: 125 mm x 211 mm x 46 mm (4.92 in. x 8.31 in. x 1.82 in.) |
Weight | 0.814 kg (1.80 lb) |
Power supply | AC/DC adaptor, 24 V; lithium-ion battery 23.760 Wh; or 4 AA auxiliary bat teries |
Battery life, lithium-ion | Operating time: minimum 12.6 h, 14 h typical, 14.7 h maximum Fast charge: 2 h to 3 h |
Standards | Designed for EN15317 |
DISPLAY | |
Color transflective VGA display |
Liquid crystal display, display area 56.16 mm x 74.88 mm (2.2 in. x 2.95 in.) |
Rectification | Full wave, RF, half-wave positive, or half-wave negative |
INPUTS/OUTPUTS | |
USB | 1.0 client |
RS-232 | Yes |
Memory card | Maximum capacity: 2 GB External MicroSD memory card |
Video output | VGA output standard |
INTERNAL DATA LOGGER | |
Data logger | The 38DL PLUS identifes, stores, recalls, clears, and transmits thickness readings, waveform images, and gage confguration information through the standard RS-232 serial port or USB port. |
Capacity | 475,000 thickness measurements or 20,000 waveforms with thickness measurements |
File names, IDs, and comments |
32-character fle names and 20-character alphanumeric location codes with four comments per location |
File structures | Nine standard or custom application-specifc fle structures |
Reports | On-gage reporting of summary with statistics, Min./Max. with locations, Min. review, fle comparison, and alarm report |
Standard Package
• 38DL PLUS digital ultrasonic thickness gage,
AC or battery operation, 50 Hz to 60 Hz
• Kits available with standard dual element
transducers
• Charger/AC adaptor (100 VAC, 115 VAC,
230 VAC)
• Internal data logger
• GageView interface program
• Test block and couplant
• USB cable
• Rubber protective boot with gage stand and
neck strap
• User’s manual
• Measurement features: THRU-COAT®, ThruPaint Echo-to-Echo, EMAT compatibility, Min./
Max. mode, two alarm modes, differential
mode, B-scan, Application Auto-Recall, temperature compensation, Average/Min. mode
picture: Olympus 38DL Plus at Semiki's warehouse
Maintenance and calibration :
► We also have calibration certificate attached ( optional )
► Please re-calibrate after use for a certain period through our purchase store. Local Vietnam : SEMIKI CORP