Máy đo nồng độ TDS atago PAL-release agent 4538

Máy đo nồng độ TDS atago PAL-release agent 4538

Máy đo nồng độ TDS atago PAL-release agent 4538

Máy đo nồng độ TDS atago PAL-release agent 4538

Máy đo nồng độ TDS atago PAL-release agent 4538
Máy đo nồng độ TDS atago PAL-release agent 4538

Sản Phẩm

  • Máy đo nồng độ TDS atago PAL-release agent 4538

  • Giá : Liên hệ
  • MASP : PAL-release agent, ATAGO 4538
  • Nhà sản xuất : ATAGO
  • Digital Hand-held "Pocket" Refractometer PAL-Release Agent. This is for concentration of release agent.With high resolution of 2 decimal places 0.01%, you can use it for the management of slight changes in concentration. This unit converts refractive index into TDS (total dissolved solids) for convenient concentration measurements of industrial wash solutions. The relationship between the concentration of Release Agent and its refractive index differs with each type of Release Agent.

Chi tiết Sản phẩm Chi tiết Sản phẩm

 

 

 

ATAGO

 

Digital Hand-held "Pocket" Refractometer

 


Model:  PAL-Release Agent 4538


This is for concentration of release agent. With high resolution of 2 decimal places 0.01%,  you can use it for the management of slight changes in concentration.

 

ATAGO Release Agent Refractometer model : PAL-Release Agent converts refractive index into TDS (total dissolved solids) for convenient concentration measurements of industrial wash solutions.


The relationship between the concentration of Release Agent and its refractive index differs with each type of Release Agent. Therefore, to determine the concentration of each type of Release Agent, each solution should have its own custom conversion table to compensate for the value displayed by instrument

 

 

 

 

Picture: ATAGO  PAL-Release Agent (0.00 to 25.00%) at Semiki's warehouse

 

 How to calculate the Conversion Factor

 

For a Release Agent solution typically used at 5% concentration:


1. Mix 95mL of water and 5mL of undiluted Release Agent solution. The concentration of this mixture solution will be 5%.

2. Measure this mixture. Assume the displayed value on the instrument is 4.00. Convert the displayed value to determine the conversion factor using the formula: [Conversion Factor = Actual concentration ÷ Displayed value] e.g. 5.00 ÷ 4.00 = 1.25

3. Once the conversion factor is known (1.25 for this example), measuring solutions with unknown concentration is simple. Assume the displayed value is 3.00 for a solution with an unknown concentration.
Using the simple formula [Concentration = Displayed value × Conversion Factor] (3.00 × 1.25), the actual concentration of the sample can be determined. E.g. 3.75 

 

Maintenance and calibration : 

 

 We also have calibration certificate attached ( optional )
► Please re-calibrate after use for a certain period through our purchase store. Local Vietnam : SEMIKI CORP

 

 

 

 

DISTRIBUTED BY:

 

Semiki instrumentation Co., Ltd
Email:  sales@semiki.com
Office tel: +84 28 2253 3522

 

 

~DOING OUR BEST FOR YOU~

 

Các sản phẩm khác

BỘ GHI DỮ LIỆU ĐA CHỨC NĂNG GRAPHTEC GL100

Chi tiết

BỘ GHI NHIỆT ĐỘ ĐỘ ẨM, ĐO ÁP SUẤT KHÍ CO2 T&D TR-76Ui

Chi tiết

ĐẦU ĐO ĐỘ RUNG TIẾP XÚC SHOWA SOKKI 2502

Chi tiết

NHIỆT KẾ GHI NHIỆT ĐỘ T&D TR41, TR42, TR45

Chi tiết

máy đo độ rung EXTECH 407860

Chi tiết

BỘ GHI NHIỆT ĐỘ CAO 2 KÊNH T&D TR-75A

Chi tiết

Yêu cầu báo giá